current limit 45 mA |
Описание оборудования | ||
---|---|---|
current limit 45 mA |
General specifications | ||
---|---|---|
Signal type | Digital Output | |
Functional safety related parameters | ||
Safety Integrity Level (SIL) | SIL 3 | |
Supply | ||
Connection | terminals 5+, 6- loop powered Power Rail or terminals 9+, 10- bus powered | |
Rated voltage | 19 ... 30 V DC | |
Input current | 75 mA at 24 V, 220 &Omega load | |
Power dissipation | 1.4 W at 24 V, 220 &Omega load | |
Input | ||
Connection side | control side | |
Connection | terminals 5+, 6- | |
Signal level | loop powered 1-signal: 19 ... 30 V DC 0-signal: 0 ... 5 V DC bus powered 1-signal: 15 ... 30 V DC (current limited at 5 mA) 0-signal: 0 ... 5 V DC | |
Rated current | 0-signal: typ. 1.6 mA at 1.5 V typ. 8 mA at 3 V (maximum leakage current DO card) 1-signal: &ge 36 mA (minmum load current DO card) | |
Output | ||
Connection side | field side | |
Connection | terminals 1+, 2- | |
Internal resistor | 285 &Omega | |
Current | typ. 45 mA | |
Voltage | typ. 10 V | |
Current limit | 45 mA | |
Open loop voltage | typ. 24.6 V | |
Load | nominal 0.05 ... 18 k&Omega | |
Output II | fault signal | |
Connection | terminals 7, 8 , non-intrinsically safe | |
Contact loading | 30 V DC/ 0.5 A resistive load | |
Mechanical life | 105 switching cycles | |
Energized/De-energized delay | &le 20 ms / &le 20 ms | |
Line fault detection | signal at short-circuit RB < 25 &Omega, lead breakage RB > 50 k&Omega test current < 500 µA | |
Galvanic isolation | ||
Output/Other circuits | basic insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff | |
Indicators/settings | ||
Display elements | LEDs | |
Control elements | DIP-switch | |
Configuration | via DIP switches | |
Labeling | space for labeling at the front | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Conformity | ||
Electromagnetic compatibility | NE 21:2012 , EN 61326-3-2:2008 For further information see system description. | |
Degree of protection | IEC 60529:2013 | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Connection | screw terminals | |
Mass | approx. 150 g | |
Dimensions | 12.5 x 114 x 119 mm (0.5 x 4.5 x 4.7 inch) , housing type A2 | |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | EXA 17 ATEX 0002 X | |
Marking | II 3(1)G Ex nC ec [ia Ga] IIC T4 Gc II (1)D [Ex ia Da] IIIC I (M1) [Ex ia Ma] I | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-7:2015 , EN 60079-11:2012 , EN 60079-15:2010 | |
International approvals | ||
IECEx approval | IECEx EXA 17.0001X | |
Approved for | Ex nC ec [ia Ga] IIC T4 Gc , [Ex ia Da] IIIC , [Ex ia Ma] I |
General specifications | ||
---|---|---|
Signal type | Digital Output | |
Functional safety related parameters | ||
Safety Integrity Level (SIL) | SIL 3 | |
Supply | ||
Connection | terminals 5+, 6- loop powered Power Rail or terminals 9+, 10- bus powered | |
Rated voltage | 19 ... 30 V DC | |
Input current | 80 mA at 24 V | |
Power dissipation | 1.3 W at 24 V | |
Load | 150 &Omega | |
Input | ||
Connection side | control side | |
Connection | terminals 5+, 6- | |
Signal level | loop powered 1-signal: 19 ... 30 V DC 0-signal: 0 ... 5 V DC bus powered 1-signal: 15 ... 30 V DC (current limited at 5 mA) 0-signal: 0 ... 5 V DC | |
Rated current | 0-signal: typ. 1.6 mA at 1.5 V typ. 8 mA at 3 V (maximum leakage current DO card) 1-signal: &ge 36 mA (minmum load current DO card) | |
Output | ||
Connection side | field side | |
Connection | terminals 1+, 2- | |
Internal resistor | 80 &Omega | |
Current | typ. 65 mA | |
Voltage | typ. 10 V | |
Current limit | 65 mA | |
Open loop voltage | typ. 16.4 V | |
Load | nominal 0.05 ... 18 k&Omega | |
Output II | fault signal | |
Connection | terminals 7, 8 , non-intrinsically safe | |
Contact loading | 30 V DC/ 0.5 A resistive load | |
Mechanical life | 105 switching cycles | |
Energized/De-energized delay | &le 20 ms / &le 20 ms | |
Line fault detection | signal at short-circuit RB < 25 &Omega, lead breakage RB > 50 k&Omega test current < 500 µA | |
Galvanic isolation | ||
Output/Other circuits | basic insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff | |
Indicators/settings | ||
Display elements | LEDs | |
Control elements | DIP-switch | |
Configuration | via DIP switches | |
Labeling | space for labeling at the front | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Conformity | ||
Electromagnetic compatibility | NE 21:2012 , EN 61326-3-2:2008 For further information see system description. | |
Degree of protection | IEC 60529:2013 | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Connection | screw terminals | |
Mass | approx. 150 g | |
Dimensions | 12.5 x 114 x 119 mm (0.5 x 4.5 x 4.7 inch) , housing type A2 | |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | EXA 17 ATEX 0002 X | |
Marking | II 3(1)G Ex nC ec [ia Ga] IIC T4 Gc II (1)D [Ex ia Da] IIIC I (M1) [Ex ia Ma] I | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-7:2015 , EN 60079-11:2012 , EN 60079-15:2010 | |
International approvals | ||
IECEx approval | IECEx EXA 17.0001X | |
Approved for | Ex nC ec [ia Ga] IIC T4 Gc , [Ex ia Da] IIIC , [Ex ia Ma] I |
General specifications | ||
---|---|---|
Signal type | Digital Output | |
Functional safety related parameters | ||
Safety Integrity Level (SIL) | SIL 3 | |
Supply | ||
Connection | terminals 5+, 6- loop powered Power Rail or terminals 9+, 10- bus powered | |
Rated voltage | 19 ... 30 V DC | |
Input current | 75 mA at 24 V , 270 &Omega load | |
Power dissipation | 1.3 W at 24 V , 270 &Omega load | |
Input | ||
Connection side | control side | |
Connection | terminals 5+, 6- | |
Signal level | loop powered 1-signal: 19 ... 30 V DC 0-signal: 0 ... 5 V DC bus powered 1-signal: 15 ... 30 V DC (current limited at 5 mA) 0-signal: 0 ... 5 V DC | |
Rated current | 0-signal: typ. 1.6 mA at 1.5 V typ. 8 mA at 3 V (maximum leakage current DO card) 1-signal: &ge 36 mA (minmum load current DO card) | |
Output | ||
Connection side | field side | |
Connection | terminals 1+, 2- | |
Internal resistor | 240 &Omega | |
Current | typ. 45 mA | |
Voltage | typ. 12 V | |
Current limit | 50 mA | |
Open loop voltage | typ. 24.6 V | |
Load | nominal 0.05 ... 18 k&Omega | |
Output II | fault signal | |
Connection | terminals 7, 8 , non-intrinsically safe | |
Contact loading | 30 V DC/ 0.5 A resistive load | |
Mechanical life | 105 switching cycles | |
Energized/De-energized delay | &le 20 ms / &le 20 ms | |
Line fault detection | signal at short-circuit RB < 25 &Omega, lead breakage RB > 50 k&Omega test current < 500 µA | |
Galvanic isolation | ||
Output/Other circuits | basic insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff | |
Indicators/settings | ||
Display elements | LEDs | |
Control elements | DIP-switch | |
Configuration | via DIP switches | |
Labeling | space for labeling at the front | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Conformity | ||
Electromagnetic compatibility | NE 21:2012 , EN 61326-3-2:2008 For further information see system description. | |
Degree of protection | IEC 60529:2013 | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Connection | screw terminals | |
Mass | approx. 150 g | |
Dimensions | 12.5 x 114 x 119 mm (0.5 x 4.5 x 4.7 inch) , housing type A2 | |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | EXA 17 ATEX 0002 X | |
Marking | II 3(1)G Ex nC ec [ia Ga] IIC T4 Gc II (1)D [Ex ia Da] IIIC I (M1) [Ex ia Ma] I | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-7:2015 , EN 60079-11:2012 , EN 60079-15:2010 | |
International approvals | ||
IECEx approval | IECEx EXA 17.0001X | |
Approved for | Ex nC ec [ia Ga] IIC T4 Gc , [Ex ia Da] IIIC , [Ex ia Ma] I |
Описание оборудования | ||
---|---|---|
current limit: 100 mA |
Описание оборудования | ||
---|---|---|
current limit 45 mA |
Описание оборудования | ||
---|---|---|
current limit 65 mA |
Описание оборудования | ||
---|---|---|
current limit 80 mA |
Описание оборудования | ||
---|---|---|
current limit 45 mA |
Описание оборудования | ||
---|---|---|
current limit 45 mA |
Описание оборудования | ||
---|---|---|
Lead monitoring |
Описание оборудования | ||
---|---|---|
Lead monitoring |
Описание оборудования | ||
---|---|---|
without lead monitoring |
General specifications | ||
---|---|---|
Signal type | Digital Output | |
Functional safety related parameters | ||
Safety Integrity Level (SIL) | SIL 2 | |
Supply | ||
Connection | Power Rail or terminals 14+, 15- | |
Rated voltage | 19 ... 30 V DC | |
Power dissipation | max. 1.5 W | |
Power consumption | max. 2 W at 45 mA output current | |
Input | ||
Connection side | control side | |
Connection | terminals 7, 8 | |
Input current | approx. 3 mA | |
Signal level | 1-signal: 16 ... 30 V DC 0-signal: 0 ... 5 V DC | |
Output | ||
Connection side | field side | |
Output I | ||
Connection | terminals 1+, 2- or 3- | |
Internal resistor | 270 &Omega | |
Current | max. 45 mA | |
Voltage | min. 11.2 V | |
Open loop voltage | min. 23.5 V | |
Output signal | These values are valid for the rated operating voltage 19 ... 30 V DC. | |
Energized/De-energized delay | &le 20 ms / &le 20 ms | |
Line fault detection | signal at short-circuit RB < 50 &Omega, lead breakage RB > 10 k&Omega test current < 650 µA | |
Output II | fault signal | |
Connection | terminals 10, 11, 12 , non-intrinsically safe | |
Contact loading | 253 V AC/2 A/cos &phi > 0.7 40 V DC/2 A resistive load | |
Mechanical life | 2 x 107 switching cycles | |
Energized/De-energized delay | &le 20 ms / &le 20 ms | |
Indicators/settings | ||
Display elements | LEDs | |
Control elements | DIP-switch | |
Configuration | via DIP switches | |
Labeling | space for labeling at the front | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Low voltage | ||
Directive 2014/35/EU | EN 61010-1:2010 | |
Conformity | ||
Electromagnetic compatibility | NE 21:2007 | |
Degree of protection | IEC 60529:2001 | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Connection | screw terminals | |
Mass | approx. 150 g | |
Dimensions | 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) , housing type B2 | |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | ZELM 99 ATEX 0015 | |
Marking | II (1)G [Ex ia Ga] IIC II (1)D [Ex ia Da] IIIC I (M1) [Ex ia Ma] I | |
Certificate | TÜV 02 ATEX 1820 X | |
Marking | II 3G Ex nA nC IIC T4 Gc | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010 , EN 60079-26:2007 , EN 50303:2000 | |
International approvals | ||
CSA approval | ||
Control drawing | 116-0362 | |
IECEx approval | IECEx ZLM 14.0001 | |
Approved for | [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I |
General specifications | ||
---|---|---|
Signal type | Digital Output | |
Functional safety related parameters | ||
Safety Integrity Level (SIL) | SIL 2 | |
Supply | ||
Connection | Power Rail or terminals 14+, 15- | |
Rated voltage | 19 ... 30 V DC | |
Power dissipation | max. 1.5 W | |
Power consumption | max. 2 W at 45 mA output current | |
Input | ||
Connection side | control side | |
Connection | terminals 7, 8 | |
Input current | 1-signal: 3.5 mA over the entire range 0-signal: 1.5 mA at 5 V DC | |
Signal level | 1-signal: 16 ... 30 V DC 0-signal: 0 ... 5 V DC | |
Output | ||
Connection side | field side | |
Output I | ||
Connection | terminals 1+, 2- or 3- | |
Internal resistor | 270 &Omega | |
Current | max. 45 mA | |
Voltage | min. 11.2 V | |
Open loop voltage | min. 23.5 V | |
Output signal | These values are valid for the rated operating voltage 19 ... 30 V DC. | |
Energized/De-energized delay | &le 20 ms / &le 20 ms | |
Line fault detection | signal at short-circuit RB < 50 &Omega, lead breakage RB > 10 k&Omega test current < 650 µA | |
Output II | fault signal | |
Connection | terminals 10, 11, 12 , non-intrinsically safe | |
Contact loading | 253 V AC/2 A/cos &phi > 0.7 40 V DC/2 A resistive load | |
Mechanical life | 2 x 107 switching cycles | |
Energized/De-energized delay | &le 20 ms / &le 20 ms | |
Indicators/settings | ||
Display elements | LEDs | |
Control elements | DIP-switch | |
Configuration | via DIP switches | |
Labeling | space for labeling at the front | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Low voltage | ||
Directive 2014/35/EU | EN 61010-1:2010 | |
Conformity | ||
Electromagnetic compatibility | NE 21:2007 | |
Degree of protection | IEC 60529:2001 | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Connection | screw terminals | |
Mass | approx. 150 g | |
Dimensions | 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) , housing type B2 | |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | ZELM 99 ATEX 0015 | |
Marking | II (1)G [Ex ia Ga] IIC II (1)D [Ex ia Da] IIIC I (M1) [Ex ia Ma] I | |
Certificate | TÜV 02 ATEX 1820 X | |
Marking | II 3G Ex nA nC IIC T4 Gc | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010 , EN 60079-26:2007 , EN 50303:2000 | |
International approvals | ||
CSA approval | ||
Control drawing | 116-0362 | |
IECEx approval | IECEx ZLM 14.0001 | |
Approved for | [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I |
General specifications | ||
---|---|---|
Signal type | Digital Output | |
Functional safety related parameters | ||
Safety Integrity Level (SIL) | SIL 2 | |
Supply | ||
Connection | Power Rail or terminals 14+, 15- | |
Rated voltage | 19 ... 30 V DC | |
Power dissipation | max. 1.5 W | |
Power consumption | max. 2 W at 45 mA output current | |
Input | ||
Connection side | control side | |
Connection | terminals 7, 8 | |
Input current | approx. 3 mA | |
Signal level | 1-signal: 16 ... 30 V DC 0-signal: 0 ... 5 V DC | |
Output | ||
Connection side | field side | |
Output I | ||
Connection | terminals 1+, 2- or 3- | |
Internal resistor | 300 &Omega | |
Current | max. 45 mA | |
Voltage | min. 10 V | |
Open loop voltage | min. 23.5 V | |
Output signal | These values are valid for the rated operating voltage 19 ... 30 V DC. | |
Energized/De-energized delay | &le 20 ms / &le 20 ms | |
Line fault detection | signal at short-circuit RB < 50 &Omega, lead breakage RB > 10 k&Omega test current < 650 µA | |
Output II | fault signal | |
Connection | terminals 10, 11, 12 , non-intrinsically safe | |
Contact loading | 253 V AC/2 A/cos &phi > 0.7 40 V DC/2 A resistive load | |
Mechanical life | 2 x 107 switching cycles | |
Energized/De-energized delay | &le 20 ms / &le 20 ms | |
Indicators/settings | ||
Display elements | LEDs | |
Control elements | DIP-switch | |
Configuration | via DIP switches | |
Labeling | space for labeling at the front | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Low voltage | ||
Directive 2014/35/EU | EN 61010-1:2010 | |
Conformity | ||
Electromagnetic compatibility | NE 21:2007 | |
Degree of protection | IEC 60529:2001 | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Connection | screw terminals | |
Mass | approx. 150 g | |
Dimensions | 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) , housing type B2 | |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | ZELM 99 ATEX 0015 | |
Marking | II (1)G [Ex ia Ga] IIC II (1)D [Ex ia Da] IIIC I (M1) [Ex ia Ma] I | |
Certificate | TÜV 02 ATEX 1820 X | |
Marking | II 3G Ex nA nC IIC T4 Gc | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010 , EN 60079-26:2007 , EN 50303:2000 | |
International approvals | ||
CSA approval | ||
Control drawing | 116-0362 | |
IECEx approval | IECEx ZLM 14.0001 | |
Approved for | [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I |
General specifications | ||
---|---|---|
Signal type | Digital Output | |
Functional safety related parameters | ||
Safety Integrity Level (SIL) | SIL 2 | |
Supply | ||
Connection | Power Rail or terminals 14+, 15- | |
Rated voltage | 19 ... 30 V DC | |
Power dissipation | max. 1.4 W | |
Power consumption | max. 2.3 W at 70 mA output current | |
Input | ||
Connection side | control side | |
Connection | terminals 7, 8 | |
Input current | approx. 3 mA | |
Signal level | 1-signal: 16 ... 30 V DC 0-signal: 0 ... 5 V DC | |
Output | ||
Connection side | field side | |
Output I | ||
Connection | terminals 1+, 2- or 3- | |
Internal resistor | 92 &Omega | |
Current | max. 70 mA | |
Voltage | min. 12.5 V | |
Open loop voltage | min. 19.2 V | |
Output signal | These values are valid for the rated operating voltage 19 ... 30 V DC. | |
Energized/De-energized delay | &le 20 ms / &le 20 ms | |
Line fault detection | signal at short-circuit RB < 50 &Omega, lead breakage RB > 10 k&Omega test current < 650 µA | |
Output II | fault signal | |
Connection | terminals 10, 11, 12 , non-intrinsically safe | |
Contact loading | 253 V AC/2 A/cos &phi > 0.7 40 V DC/2 A resistive load | |
Mechanical life | 2 x 107 switching cycles | |
Energized/De-energized delay | &le 20 ms / &le 20 ms | |
Indicators/settings | ||
Display elements | LEDs | |
Control elements | DIP-switch | |
Configuration | via DIP switches | |
Labeling | space for labeling at the front | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Low voltage | ||
Directive 2014/35/EU | EN 61010-1:2010 | |
Conformity | ||
Electromagnetic compatibility | NE 21:2007 | |
Degree of protection | IEC 60529:2001 | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Connection | screw terminals | |
Mass | approx. 150 g | |
Dimensions | 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) , housing type B2 | |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | ZELM 99 ATEX 0015 | |
Marking | II (1)G [Ex ia Ga] IIB II (1)D [Ex ia Da] IIIC I (M1) [Ex ia Ma] I | |
Certificate | TÜV 02 ATEX 1820 X | |
Marking | II 3G Ex nA nC IIC T4 Gc | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010 , EN 60079-26:2007 , EN 50303:2000 | |
International approvals | ||
CSA approval | ||
Control drawing | 116-0362 | |
IECEx approval | IECEx ZLM 14.0001 | |
Approved for | [Ex ia Ga] IIB, [Ex ia Da] IIIC, [Ex ia Ma] I |
General specifications | ||
---|---|---|
Signal type | Digital Output | |
Functional safety related parameters | ||
Safety Integrity Level (SIL) | SIL 2 | |
Supply | ||
Connection | Power Rail or terminals 14+, 15- | |
Rated voltage | 20 ... 30 V DC | |
Power consumption | max. 3.3 W at 45 mA output current | |
Input | ||
Connection side | control side | |
Connection | terminals 7, 8, 9 | |
Input current | approx. 3 mA at 24 V DC | |
Signal level | 1-signal: 16 ... 30 V DC 0-signal: 0 ... 5 V DC | |
Output | ||
Connection side | field side | |
Connection | channel 1: terminals 1+, 2-, 3 channel 2: terminals 4+, 5-, 6- | |
Internal resistor | 272 &Omega | |
Current | &le 45 mA | |
Voltage | &ge 11.7 V | |
Open loop voltage | min. 24 V | |
Output signal | These values are valid for the rated operating voltages from 20 ... 30 V DC. | |
Energized/De-energized delay | &le 20 ms / &le 20 ms | |
Line fault detection | signal at short-circuit RB < 50 &Omega, lead breakage RB > 10 k&Omega , test current < 650 µA | |
Indicators/settings | ||
Display elements | LEDs | |
Control elements | DIP-switch | |
Configuration | via DIP switches | |
Labeling | space for labeling at the front | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Conformity | ||
Electromagnetic compatibility | NE 21:2006 | |
Degree of protection | IEC 60529:2001 | |
Ambient conditions | ||
Ambient temperature | -20 ... 50 °C (-4 ... 122 °F) | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Connection | screw terminals | |
Mass | approx. 150 g | |
Dimensions | 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) , housing type B2 | |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | ZELM 00 ATEX 0024 | |
Marking | II (1)G [Ex ia Ga] IIC II (1)D [Ex ia Da] IIIC I (M1) [Ex ia Ma] I | |
Certificate | TÜV 02 ATEX 1820 X | |
Marking | II 3G Ex nA IIC T4 Gc | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010 , EN 60079-26:2007 , EN 50303:2000 | |
International approvals | ||
CSA approval | ||
Control drawing | 116-0304 | |
IECEx approval | IECEx TUN 04.0001 | |
Approved for | [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I |
Описание оборудования | ||
---|---|---|
without lead monitoring |
Описание оборудования | ||
---|---|---|
Output 22.3 V |