| General specifications | ||
|---|---|---|
| Signal type | Digital Output | |
| Functional safety related parameters | ||
| Safety Integrity Level (SIL) | SIL 3 | |
| Supply | ||
| Connection | terminals 5+, 6- loop powered Power Rail or terminals 9+, 10- bus powered | |
| Rated voltage | 19 ... 30 V DC | |
| Input current | 75 mA at 24 V, 220 &Omega load | |
| Power dissipation | 1.4 W at 24 V, 220 &Omega load | |
| Input | ||
| Connection side | control side | |
| Connection | terminals 5+, 6- | |
| Signal level | loop powered 1-signal: 19 ... 30 V DC 0-signal: 0 ... 5 V DC bus powered 1-signal: 15 ... 30 V DC (current limited at 5 mA) 0-signal: 0 ... 5 V DC | |
| Rated current | 0-signal: typ. 1.6 mA at 1.5 V typ. 8 mA at 3 V (maximum leakage current DO card) 1-signal: &ge 36 mA (minmum load current DO card) | |
| Output | ||
| Connection side | field side | |
| Connection | terminals 1+, 2- | |
| Internal resistor | 285 &Omega | |
| Current | typ. 45 mA | |
| Voltage | typ. 10 V | |
| Current limit | 45 mA | |
| Open loop voltage | typ. 24.6 V | |
| Load | nominal 0.05 ... 18 k&Omega | |
| Output II | fault signal | |
| Connection | terminals 7, 8 , non-intrinsically safe | |
| Contact loading | 30 V DC/ 0.5 A resistive load | |
| Mechanical life | 105 switching cycles | |
| Energized/De-energized delay | &le 20 ms / &le 20 ms | |
| Line fault detection | signal at short-circuit RB < 25 &Omega, lead breakage RB > 50 k&Omega test current < 500 µA | |
| Galvanic isolation | ||
| Output/Other circuits | basic insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff | |
| Indicators/settings | ||
| Display elements | LEDs | |
| Control elements | DIP-switch | |
| Configuration | via DIP switches | |
| Labeling | space for labeling at the front | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Electromagnetic compatibility | NE 21:2012 , EN 61326-3-2:2008 For further information see system description. | |
| Degree of protection | IEC 60529:2013 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Connection | screw terminals | |
| Mass | approx. 150 g | |
| Dimensions | 12.5 x 114 x 119 mm (0.5 x 4.5 x 4.7 inch) , housing type A2 | |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
| Data for application in connection with hazardous areas | ||
| EU-Type Examination Certificate | EXA 17 ATEX 0002 X | |
| Marking | II 3(1)G Ex nC ec [ia Ga] IIC T4 Gc II (1)D [Ex ia Da] IIIC I (M1) [Ex ia Ma] I | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-7:2015 , EN 60079-11:2012 , EN 60079-15:2010 | |
| International approvals | ||
| IECEx approval | IECEx EXA 17.0001X | |
| Approved for | Ex nC ec [ia Ga] IIC T4 Gc , [Ex ia Da] IIIC , [Ex ia Ma] I | |
| General specifications | ||
|---|---|---|
| Signal type | Digital Output | |
| Functional safety related parameters | ||
| Safety Integrity Level (SIL) | SIL 3 | |
| Supply | ||
| Connection | terminals 5+, 6- loop powered Power Rail or terminals 9+, 10- bus powered | |
| Rated voltage | 19 ... 30 V DC | |
| Input current | 80 mA at 24 V | |
| Power dissipation | 1.3 W at 24 V | |
| Load | 150 &Omega | |
| Input | ||
| Connection side | control side | |
| Connection | terminals 5+, 6- | |
| Signal level | loop powered 1-signal: 19 ... 30 V DC 0-signal: 0 ... 5 V DC bus powered 1-signal: 15 ... 30 V DC (current limited at 5 mA) 0-signal: 0 ... 5 V DC | |
| Rated current | 0-signal: typ. 1.6 mA at 1.5 V typ. 8 mA at 3 V (maximum leakage current DO card) 1-signal: &ge 36 mA (minmum load current DO card) | |
| Output | ||
| Connection side | field side | |
| Connection | terminals 1+, 2- | |
| Internal resistor | 80 &Omega | |
| Current | typ. 65 mA | |
| Voltage | typ. 10 V | |
| Current limit | 65 mA | |
| Open loop voltage | typ. 16.4 V | |
| Load | nominal 0.05 ... 18 k&Omega | |
| Output II | fault signal | |
| Connection | terminals 7, 8 , non-intrinsically safe | |
| Contact loading | 30 V DC/ 0.5 A resistive load | |
| Mechanical life | 105 switching cycles | |
| Energized/De-energized delay | &le 20 ms / &le 20 ms | |
| Line fault detection | signal at short-circuit RB < 25 &Omega, lead breakage RB > 50 k&Omega test current < 500 µA | |
| Galvanic isolation | ||
| Output/Other circuits | basic insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff | |
| Indicators/settings | ||
| Display elements | LEDs | |
| Control elements | DIP-switch | |
| Configuration | via DIP switches | |
| Labeling | space for labeling at the front | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Electromagnetic compatibility | NE 21:2012 , EN 61326-3-2:2008 For further information see system description. | |
| Degree of protection | IEC 60529:2013 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Connection | screw terminals | |
| Mass | approx. 150 g | |
| Dimensions | 12.5 x 114 x 119 mm (0.5 x 4.5 x 4.7 inch) , housing type A2 | |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
| Data for application in connection with hazardous areas | ||
| EU-Type Examination Certificate | EXA 17 ATEX 0002 X | |
| Marking | II 3(1)G Ex nC ec [ia Ga] IIC T4 Gc II (1)D [Ex ia Da] IIIC I (M1) [Ex ia Ma] I | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-7:2015 , EN 60079-11:2012 , EN 60079-15:2010 | |
| International approvals | ||
| IECEx approval | IECEx EXA 17.0001X | |
| Approved for | Ex nC ec [ia Ga] IIC T4 Gc , [Ex ia Da] IIIC , [Ex ia Ma] I | |
| General specifications | ||
|---|---|---|
| Signal type | Digital Output | |
| Functional safety related parameters | ||
| Safety Integrity Level (SIL) | SIL 3 | |
| Supply | ||
| Connection | terminals 5+, 6- loop powered Power Rail or terminals 9+, 10- bus powered | |
| Rated voltage | 19 ... 30 V DC | |
| Input current | 75 mA at 24 V , 270 &Omega load | |
| Power dissipation | 1.3 W at 24 V , 270 &Omega load | |
| Input | ||
| Connection side | control side | |
| Connection | terminals 5+, 6- | |
| Signal level | loop powered 1-signal: 19 ... 30 V DC 0-signal: 0 ... 5 V DC bus powered 1-signal: 15 ... 30 V DC (current limited at 5 mA) 0-signal: 0 ... 5 V DC | |
| Rated current | 0-signal: typ. 1.6 mA at 1.5 V typ. 8 mA at 3 V (maximum leakage current DO card) 1-signal: &ge 36 mA (minmum load current DO card) | |
| Output | ||
| Connection side | field side | |
| Connection | terminals 1+, 2- | |
| Internal resistor | 240 &Omega | |
| Current | typ. 45 mA | |
| Voltage | typ. 12 V | |
| Current limit | 50 mA | |
| Open loop voltage | typ. 24.6 V | |
| Load | nominal 0.05 ... 18 k&Omega | |
| Output II | fault signal | |
| Connection | terminals 7, 8 , non-intrinsically safe | |
| Contact loading | 30 V DC/ 0.5 A resistive load | |
| Mechanical life | 105 switching cycles | |
| Energized/De-energized delay | &le 20 ms / &le 20 ms | |
| Line fault detection | signal at short-circuit RB < 25 &Omega, lead breakage RB > 50 k&Omega test current < 500 µA | |
| Galvanic isolation | ||
| Output/Other circuits | basic insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff | |
| Indicators/settings | ||
| Display elements | LEDs | |
| Control elements | DIP-switch | |
| Configuration | via DIP switches | |
| Labeling | space for labeling at the front | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Electromagnetic compatibility | NE 21:2012 , EN 61326-3-2:2008 For further information see system description. | |
| Degree of protection | IEC 60529:2013 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Connection | screw terminals | |
| Mass | approx. 150 g | |
| Dimensions | 12.5 x 114 x 119 mm (0.5 x 4.5 x 4.7 inch) , housing type A2 | |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
| Data for application in connection with hazardous areas | ||
| EU-Type Examination Certificate | EXA 17 ATEX 0002 X | |
| Marking | II 3(1)G Ex nC ec [ia Ga] IIC T4 Gc II (1)D [Ex ia Da] IIIC I (M1) [Ex ia Ma] I | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-7:2015 , EN 60079-11:2012 , EN 60079-15:2010 | |
| International approvals | ||
| IECEx approval | IECEx EXA 17.0001X | |
| Approved for | Ex nC ec [ia Ga] IIC T4 Gc , [Ex ia Da] IIIC , [Ex ia Ma] I | |
| Описание оборудования | ||
|---|---|---|
| current limit: 100 mA | ||
| Описание оборудования | ||
|---|---|---|
| current limit 45 mA | ||
| Описание оборудования | ||
|---|---|---|
| current limit 65 mA | ||
| Описание оборудования | ||
|---|---|---|
| current limit 80 mA | ||
| Описание оборудования | ||
|---|---|---|
| current limit 45 mA | ||
| Описание оборудования | ||
|---|---|---|
| current limit 45 mA | ||
| Описание оборудования | ||
|---|---|---|
| Lead monitoring | ||
| Описание оборудования | ||
|---|---|---|
| Lead monitoring | ||
| Описание оборудования | ||
|---|---|---|
| without lead monitoring | ||
| General specifications | ||
|---|---|---|
| Signal type | Digital Output | |
| Functional safety related parameters | ||
| Safety Integrity Level (SIL) | SIL 2 | |
| Supply | ||
| Connection | Power Rail or terminals 14+, 15- | |
| Rated voltage | 19 ... 30 V DC | |
| Power dissipation | max. 1.5 W | |
| Power consumption | max. 2 W at 45 mA output current | |
| Input | ||
| Connection side | control side | |
| Connection | terminals 7, 8 | |
| Input current | approx. 3 mA | |
| Signal level | 1-signal: 16 ... 30 V DC 0-signal: 0 ... 5 V DC | |
| Output | ||
| Connection side | field side | |
| Output I | ||
| Connection | terminals 1+, 2- or 3- | |
| Internal resistor | 270 &Omega | |
| Current | max. 45 mA | |
| Voltage | min. 11.2 V | |
| Open loop voltage | min. 23.5 V | |
| Output signal | These values are valid for the rated operating voltage 19 ... 30 V DC. | |
| Energized/De-energized delay | &le 20 ms / &le 20 ms | |
| Line fault detection | signal at short-circuit RB < 50 &Omega, lead breakage RB > 10 k&Omega test current < 650 µA | |
| Output II | fault signal | |
| Connection | terminals 10, 11, 12 , non-intrinsically safe | |
| Contact loading | 253 V AC/2 A/cos &phi > 0.7 40 V DC/2 A resistive load | |
| Mechanical life | 2 x 107 switching cycles | |
| Energized/De-energized delay | &le 20 ms / &le 20 ms | |
| Indicators/settings | ||
| Display elements | LEDs | |
| Control elements | DIP-switch | |
| Configuration | via DIP switches | |
| Labeling | space for labeling at the front | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Low voltage | ||
| Directive 2014/35/EU | EN 61010-1:2010 | |
| Conformity | ||
| Electromagnetic compatibility | NE 21:2007 | |
| Degree of protection | IEC 60529:2001 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Connection | screw terminals | |
| Mass | approx. 150 g | |
| Dimensions | 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) , housing type B2 | |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
| Data for application in connection with hazardous areas | ||
| EU-Type Examination Certificate | ZELM 99 ATEX 0015 | |
| Marking | II (1)G [Ex ia Ga] IIC II (1)D [Ex ia Da] IIIC I (M1) [Ex ia Ma] I | |
| Certificate | TÜV 02 ATEX 1820 X | |
| Marking | II 3G Ex nA nC IIC T4 Gc | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010 , EN 60079-26:2007 , EN 50303:2000 | |
| International approvals | ||
| CSA approval | ||
| Control drawing | 116-0362 | |
| IECEx approval | IECEx ZLM 14.0001 | |
| Approved for | [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I | |
| General specifications | ||
|---|---|---|
| Signal type | Digital Output | |
| Functional safety related parameters | ||
| Safety Integrity Level (SIL) | SIL 2 | |
| Supply | ||
| Connection | Power Rail or terminals 14+, 15- | |
| Rated voltage | 19 ... 30 V DC | |
| Power dissipation | max. 1.5 W | |
| Power consumption | max. 2 W at 45 mA output current | |
| Input | ||
| Connection side | control side | |
| Connection | terminals 7, 8 | |
| Input current | 1-signal: 3.5 mA over the entire range 0-signal: 1.5 mA at 5 V DC | |
| Signal level | 1-signal: 16 ... 30 V DC 0-signal: 0 ... 5 V DC | |
| Output | ||
| Connection side | field side | |
| Output I | ||
| Connection | terminals 1+, 2- or 3- | |
| Internal resistor | 270 &Omega | |
| Current | max. 45 mA | |
| Voltage | min. 11.2 V | |
| Open loop voltage | min. 23.5 V | |
| Output signal | These values are valid for the rated operating voltage 19 ... 30 V DC. | |
| Energized/De-energized delay | &le 20 ms / &le 20 ms | |
| Line fault detection | signal at short-circuit RB < 50 &Omega, lead breakage RB > 10 k&Omega test current < 650 µA | |
| Output II | fault signal | |
| Connection | terminals 10, 11, 12 , non-intrinsically safe | |
| Contact loading | 253 V AC/2 A/cos &phi > 0.7 40 V DC/2 A resistive load | |
| Mechanical life | 2 x 107 switching cycles | |
| Energized/De-energized delay | &le 20 ms / &le 20 ms | |
| Indicators/settings | ||
| Display elements | LEDs | |
| Control elements | DIP-switch | |
| Configuration | via DIP switches | |
| Labeling | space for labeling at the front | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Low voltage | ||
| Directive 2014/35/EU | EN 61010-1:2010 | |
| Conformity | ||
| Electromagnetic compatibility | NE 21:2007 | |
| Degree of protection | IEC 60529:2001 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Connection | screw terminals | |
| Mass | approx. 150 g | |
| Dimensions | 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) , housing type B2 | |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
| Data for application in connection with hazardous areas | ||
| EU-Type Examination Certificate | ZELM 99 ATEX 0015 | |
| Marking | II (1)G [Ex ia Ga] IIC II (1)D [Ex ia Da] IIIC I (M1) [Ex ia Ma] I | |
| Certificate | TÜV 02 ATEX 1820 X | |
| Marking | II 3G Ex nA nC IIC T4 Gc | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010 , EN 60079-26:2007 , EN 50303:2000 | |
| International approvals | ||
| CSA approval | ||
| Control drawing | 116-0362 | |
| IECEx approval | IECEx ZLM 14.0001 | |
| Approved for | [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I | |
| General specifications | ||
|---|---|---|
| Signal type | Digital Output | |
| Functional safety related parameters | ||
| Safety Integrity Level (SIL) | SIL 2 | |
| Supply | ||
| Connection | Power Rail or terminals 14+, 15- | |
| Rated voltage | 19 ... 30 V DC | |
| Power dissipation | max. 1.5 W | |
| Power consumption | max. 2 W at 45 mA output current | |
| Input | ||
| Connection side | control side | |
| Connection | terminals 7, 8 | |
| Input current | approx. 3 mA | |
| Signal level | 1-signal: 16 ... 30 V DC 0-signal: 0 ... 5 V DC | |
| Output | ||
| Connection side | field side | |
| Output I | ||
| Connection | terminals 1+, 2- or 3- | |
| Internal resistor | 300 &Omega | |
| Current | max. 45 mA | |
| Voltage | min. 10 V | |
| Open loop voltage | min. 23.5 V | |
| Output signal | These values are valid for the rated operating voltage 19 ... 30 V DC. | |
| Energized/De-energized delay | &le 20 ms / &le 20 ms | |
| Line fault detection | signal at short-circuit RB < 50 &Omega, lead breakage RB > 10 k&Omega test current < 650 µA | |
| Output II | fault signal | |
| Connection | terminals 10, 11, 12 , non-intrinsically safe | |
| Contact loading | 253 V AC/2 A/cos &phi > 0.7 40 V DC/2 A resistive load | |
| Mechanical life | 2 x 107 switching cycles | |
| Energized/De-energized delay | &le 20 ms / &le 20 ms | |
| Indicators/settings | ||
| Display elements | LEDs | |
| Control elements | DIP-switch | |
| Configuration | via DIP switches | |
| Labeling | space for labeling at the front | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Low voltage | ||
| Directive 2014/35/EU | EN 61010-1:2010 | |
| Conformity | ||
| Electromagnetic compatibility | NE 21:2007 | |
| Degree of protection | IEC 60529:2001 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Connection | screw terminals | |
| Mass | approx. 150 g | |
| Dimensions | 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) , housing type B2 | |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
| Data for application in connection with hazardous areas | ||
| EU-Type Examination Certificate | ZELM 99 ATEX 0015 | |
| Marking | II (1)G [Ex ia Ga] IIC II (1)D [Ex ia Da] IIIC I (M1) [Ex ia Ma] I | |
| Certificate | TÜV 02 ATEX 1820 X | |
| Marking | II 3G Ex nA nC IIC T4 Gc | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010 , EN 60079-26:2007 , EN 50303:2000 | |
| International approvals | ||
| CSA approval | ||
| Control drawing | 116-0362 | |
| IECEx approval | IECEx ZLM 14.0001 | |
| Approved for | [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I | |
| General specifications | ||
|---|---|---|
| Signal type | Digital Output | |
| Functional safety related parameters | ||
| Safety Integrity Level (SIL) | SIL 2 | |
| Supply | ||
| Connection | Power Rail or terminals 14+, 15- | |
| Rated voltage | 19 ... 30 V DC | |
| Power dissipation | max. 1.4 W | |
| Power consumption | max. 2.3 W at 70 mA output current | |
| Input | ||
| Connection side | control side | |
| Connection | terminals 7, 8 | |
| Input current | approx. 3 mA | |
| Signal level | 1-signal: 16 ... 30 V DC 0-signal: 0 ... 5 V DC | |
| Output | ||
| Connection side | field side | |
| Output I | ||
| Connection | terminals 1+, 2- or 3- | |
| Internal resistor | 92 &Omega | |
| Current | max. 70 mA | |
| Voltage | min. 12.5 V | |
| Open loop voltage | min. 19.2 V | |
| Output signal | These values are valid for the rated operating voltage 19 ... 30 V DC. | |
| Energized/De-energized delay | &le 20 ms / &le 20 ms | |
| Line fault detection | signal at short-circuit RB < 50 &Omega, lead breakage RB > 10 k&Omega test current < 650 µA | |
| Output II | fault signal | |
| Connection | terminals 10, 11, 12 , non-intrinsically safe | |
| Contact loading | 253 V AC/2 A/cos &phi > 0.7 40 V DC/2 A resistive load | |
| Mechanical life | 2 x 107 switching cycles | |
| Energized/De-energized delay | &le 20 ms / &le 20 ms | |
| Indicators/settings | ||
| Display elements | LEDs | |
| Control elements | DIP-switch | |
| Configuration | via DIP switches | |
| Labeling | space for labeling at the front | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Low voltage | ||
| Directive 2014/35/EU | EN 61010-1:2010 | |
| Conformity | ||
| Electromagnetic compatibility | NE 21:2007 | |
| Degree of protection | IEC 60529:2001 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Connection | screw terminals | |
| Mass | approx. 150 g | |
| Dimensions | 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) , housing type B2 | |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
| Data for application in connection with hazardous areas | ||
| EU-Type Examination Certificate | ZELM 99 ATEX 0015 | |
| Marking | II (1)G [Ex ia Ga] IIB II (1)D [Ex ia Da] IIIC I (M1) [Ex ia Ma] I | |
| Certificate | TÜV 02 ATEX 1820 X | |
| Marking | II 3G Ex nA nC IIC T4 Gc | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010 , EN 60079-26:2007 , EN 50303:2000 | |
| International approvals | ||
| CSA approval | ||
| Control drawing | 116-0362 | |
| IECEx approval | IECEx ZLM 14.0001 | |
| Approved for | [Ex ia Ga] IIB, [Ex ia Da] IIIC, [Ex ia Ma] I | |
| General specifications | ||
|---|---|---|
| Signal type | Digital Output | |
| Functional safety related parameters | ||
| Safety Integrity Level (SIL) | SIL 2 | |
| Supply | ||
| Connection | Power Rail or terminals 14+, 15- | |
| Rated voltage | 20 ... 30 V DC | |
| Power consumption | max. 3.3 W at 45 mA output current | |
| Input | ||
| Connection side | control side | |
| Connection | terminals 7, 8, 9 | |
| Input current | approx. 3 mA at 24 V DC | |
| Signal level | 1-signal: 16 ... 30 V DC 0-signal: 0 ... 5 V DC | |
| Output | ||
| Connection side | field side | |
| Connection | channel 1: terminals 1+, 2-, 3 channel 2: terminals 4+, 5-, 6- | |
| Internal resistor | 272 &Omega | |
| Current | &le 45 mA | |
| Voltage | &ge 11.7 V | |
| Open loop voltage | min. 24 V | |
| Output signal | These values are valid for the rated operating voltages from 20 ... 30 V DC. | |
| Energized/De-energized delay | &le 20 ms / &le 20 ms | |
| Line fault detection | signal at short-circuit RB < 50 &Omega, lead breakage RB > 10 k&Omega , test current < 650 µA | |
| Indicators/settings | ||
| Display elements | LEDs | |
| Control elements | DIP-switch | |
| Configuration | via DIP switches | |
| Labeling | space for labeling at the front | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Electromagnetic compatibility | NE 21:2006 | |
| Degree of protection | IEC 60529:2001 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 50 °C (-4 ... 122 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Connection | screw terminals | |
| Mass | approx. 150 g | |
| Dimensions | 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) , housing type B2 | |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
| Data for application in connection with hazardous areas | ||
| EU-Type Examination Certificate | ZELM 00 ATEX 0024 | |
| Marking | II (1)G [Ex ia Ga] IIC II (1)D [Ex ia Da] IIIC I (M1) [Ex ia Ma] I | |
| Certificate | TÜV 02 ATEX 1820 X | |
| Marking | II 3G Ex nA IIC T4 Gc | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010 , EN 60079-26:2007 , EN 50303:2000 | |
| International approvals | ||
| CSA approval | ||
| Control drawing | 116-0304 | |
| IECEx approval | IECEx TUN 04.0001 | |
| Approved for | [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I | |
| Описание оборудования | ||
|---|---|---|
| without lead monitoring | ||
| Описание оборудования | ||
|---|---|---|
| Output 22.3 V | ||