Атол 30Ф не включается (заводской брак)
Валерий
14 января 2022
| Описание оборудования | ||
|---|---|---|
| Stack light LED permanent light element, yellow | ||
| Описание оборудования | ||
|---|---|---|
| Stack light mounting base | ||
| Описание оборудования | ||
|---|---|---|
| Stack light siren element 8 tone | ||
| Описание оборудования | ||
|---|---|---|
| Stack light solid light element, blue | ||
| Описание оборудования | ||
|---|---|---|
| Stack light solid light element, clear | ||
| Описание оборудования | ||
|---|---|---|
| Stack light permanent light element, green | ||
| Описание оборудования | ||
|---|---|---|
| Stack light solid light element, red | ||
| Описание оборудования | ||
|---|---|---|
| Stack light solid light element, yellow | ||
| Описание оборудования | ||
|---|---|---|
| Stack light terminal base with cover plate | ||
| Описание оборудования | ||
|---|---|---|
| Signal tower connection element with end cover and M12 connection | ||
| Описание оборудования | ||
|---|---|---|
| Stack light terminal base with cover plate | ||
| Описание оборудования | ||
|---|---|---|
| Stack light upright, straight | ||
| Описание оборудования | ||
|---|---|---|
| AS-Interface | ||
| General specifications | ||
|---|---|---|
| Switching function | Normally open/closed (NO/NC) programmable | |
| Output type | AS-Interface | |
| Rated operating distance | 20 mm | |
| Installation | flush | |
| Assured operating distance | 0 ... 16.2 mm | |
| Reduction factor rAl | 0.33 | |
| Reduction factor rCu | 0.31 | |
| Reduction factor r304 | 0.74 | |
| Reduction factor rBrass | 0.41 | |
| Slave type | Standard slave | |
| AS-Interface specification | V2.1 | |
| Required master specification | &ge V2.1 | |
| Nominal ratings | ||
| Operating voltage | 26.5 ... 31.9 V via AS-i bus system | |
| Switching frequency | 0 ... 150 Hz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | reverse polarity protected | |
| No-load supply current | &le 40 mA | |
| Operating voltage indicator | LED, green | |
| Switching state indicator | dual-LED, yellow | |
| Error indicator | dual-LED, red | |
| Functional safety related parameters | ||
| MTTFd | 1330 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | Connector M12 x 1 , 4-pin | |
| Housing material | PA | |
| Sensing face | PA | |
| Degree of protection | IP69K | |
| Mass | 130 g | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open/closed (NO/NC) programmable | |
| Output type | AS-Interface | |
| Rated operating distance | 20 mm | |
| Installation | flush | |
| Assured operating distance | 0 ... 16.2 mm | |
| Reduction factor rAl | 0.33 | |
| Reduction factor rCu | 0.31 | |
| Reduction factor r304 | 0.74 | |
| Reduction factor rBrass | 0.41 | |
| Slave type | A/B slave | |
| AS-Interface specification | V3.0 | |
| Required master specification | &ge V2.1 | |
| Nominal ratings | ||
| Operating voltage | 26.5 ... 31.9 V via AS-i bus system | |
| Switching frequency | 0 ... 150 Hz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | reverse polarity protected | |
| No-load supply current | &le 40 mA | |
| Operating voltage indicator | LED, green | |
| Switching state indicator | LED, yellow | |
| Error indicator | LED, red | |
| Functional safety related parameters | ||
| MTTFd | 1330 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | Connector M12 x 1 , 4-pin | |
| Housing material | PA | |
| Sensing face | PA | |
| Degree of protection | IP69K | |
| Mass | 130 g | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open/closed (NO/NC) programmable | |
| Output type | AS-Interface | |
| Rated operating distance | 20 mm | |
| Installation | flush | |
| Assured operating distance | 0 ... 16.2 mm | |
| Actual operating distance | 18 ... 22 mm typ. 20 mm | |
| Reduction factor rAl | 0.4 | |
| Reduction factor rCu | 0.35 | |
| Reduction factor r304 | 0.85 | |
| Slave type | A/B slave | |
| AS-Interface specification | V3.0 | |
| Required master specification | &ge V2.1 | |
| Nominal ratings | ||
| Operating voltage | 26.5 ... 31.9 V via AS-i bus system | |
| Switching frequency | 0 ... 150 Hz | |
| Hysteresis | 1 ... 15 typ. 5 % | |
| Reverse polarity protection | reverse polarity protected | |
| No-load supply current | &le 25 mA | |
| Operating voltage indicator | LED, green | |
| Switching state indicator | LED, yellow | |
| Error indicator | LED, red | |
| Functional safety related parameters | ||
| MTTFd | 1330 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | screw terminals | |
| Information for connection | A maximum of two conductors with the same core cross section may be mounted on one terminal connection! tightening torque 1.2 Nm + 10 % | |
| Core cross-section | up to 2.5 mm2 | |
| Minimum core cross-section | without wire end ferrule 0.5 mm2 , with connector sleeves 0.34 mm2 | |
| Maximum core cross-section | without wire end ferrule 2.5 mm2 , with connector sleeves 1.5 mm2 | |
| Housing material | PA/metal with epoxy powder coating | |
| Sensing face | PBT | |
| Housing diameter | ||
| Degree of protection | IP68 / IP69K | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open/closed (NO/NC) programmable | |
| Output type | AS-Interface | |
| Rated operating distance | 6 mm | |
| Installation | flush | |
| Assured operating distance | 0 ... 4.86 mm | |
| Reduction factor rAl | 0.28 | |
| Reduction factor rCu | 0.25 | |
| Reduction factor r304 | 0.75 | |
| Slave type | Standard slave | |
| AS-Interface specification | V2.1 | |
| Required master specification | &ge V2.1 | |
| Nominal ratings | ||
| Operating voltage | 26.5 ... 31.9 V via AS-i bus system | |
| Switching frequency | &ge 500 (P3=0), | |
| Hysteresis | typ. 5 % | |
| Operating current | 20 mA | |
| Functional safety related parameters | ||
| MTTFd | 1873 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Indicators/operating means | ||
| LED POWER | AS-Interface voltage LED green | |
| LED IN | switching state (input) LED yellow | |
| LED OUT | Dual LED yellow/red yellow: switching state red: error mode | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 2 m | |
| Core cross-section | 0.34 mm2 | |
| Housing material | PBT | |
| Degree of protection | IP67 | |
| Mass | 90 g | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open/closed (NO/NC) programmable | |
| Output type | AS-Interface | |
| Rated operating distance | 6 mm | |
| Installation | flush | |
| Assured operating distance | 0 ... 4.86 mm | |
| Reduction factor rAl | 0.28 | |
| Reduction factor rCu | 0.25 | |
| Reduction factor r304 | 0.75 | |
| Slave type | A/B slave | |
| AS-Interface specification | V3.0 | |
| Required master specification | &ge V2.1 | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Operating voltage | 26.5 ... 31.9 V via AS-i bus system | |
| Switching frequency | &ge 500 (P3=0), &ge 100 (P3=1) | |
| Hysteresis | typ. 5 % | |
| Operating current | 20 mA | |
| Functional safety related parameters | ||
| MTTFd | 532 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Indicators/operating means | ||
| LED POWER | AS-Interface voltage LED green | |
| LED IN | switching state (input) LED yellow | |
| LED OUT | Dual LED yellow/red yellow: switching state red: error mode | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 2 m | |
| Core cross-section | 0.34 mm2 | |
| Housing material | PBT | |
| Degree of protection | IP67 | |
| Mass | 90 g | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open/closed (NO/NC) programmable | |
| Output type | AS-Interface | |
| Rated operating distance | 8 mm | |
| Installation | flush | |
| Assured operating distance | 0 ... 6.48 mm | |
| Reduction factor rAl | 0.4 | |
| Reduction factor rCu | 0.4 | |
| Reduction factor r304 | 0.7 | |
| Reduction factor rBrass | 0.5 | |
| Slave type | Standard slave | |
| AS-Interface specification | V2.1 | |
| Required master specification | &ge V2.0 | |
| Nominal ratings | ||
| Operating voltage | 26.5 ... 31.9 V via AS-i bus system | |
| Switching frequency | 0 ... 200 Hz | |
| Hysteresis | 1 ... 15 typ. 5 % | |
| Reverse polarity protection | reverse polarity protected | |
| No-load supply current | &le 25 mA | |
| Switching state indicator | dual-LED, yellow | |
| Error indicator | dual-LED, red | |
| Functional safety related parameters | ||
| MTTFd | 926 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | 4-pin, M12 x 1 connector | |
| Housing material | brass, nickel-plated | |
| Sensing face | PBT | |
| Housing diameter | 18 mm | |
| Degree of protection | IP67 | |
| Описание оборудования | ||
|---|---|---|
| AS-Interface | ||
| General specifications | ||
|---|---|---|
| Switching function | 2 x normally open (NO) | |
| Output type | PNP | |
| Rated operating distance | 2.5 mm | |
| Installation | for non-flush mounting | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 2.05 mm | |
| Output type | 4-wire | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V | |
| Switching frequency | 0 ... 100 Hz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | all connections | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 100 mA | |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA | |
| No-load supply current | &le 25 mA | |
| Operating voltage indicator | LED, green | |
| Switching state indicator | LED, yellow | |
| Valve status indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 605 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| EAC conformity | TR CU 020/2011 | |
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| Ambient conditions | ||
| Ambient temperature | -40 ... 75 °C (-40 ... 167 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection (system side) | screw terminal , M20 x 1.5 cable gland | |
| Core cross-section (system side) | 1.5/2.5 mm2 flexible/rigid | |
| Connection (valve side) | 4-pin, M12 x 1 socket | |
| Housing material | rugged, translucent polycarbonate (PC) optimised for outdoor use | |
| Degree of protection | IP66 / IP67 / IP69K | |
| Tightening torque, housing screws | &le 2 Nm | |
| Tightening torque, cable gland | M20 x 1.5 max. 4 Nm M12 x 1 max. 3 Nm | |
| Tightening torque, stopping plug | 1 Nm | |
| General specifications | ||
|---|---|---|
| Switching function | 2 x normally open (NO) | |
| Output type | Two-wire | |
| Rated operating distance | 2.5 mm | |
| Installation | for non-flush mounting | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 2.05 mm | |
| Output type | 2x 2-wire | |
| Nominal ratings | ||
| Operating voltage | 6 ... 30 V | |
| Switching frequency | 0 ... 100 Hz | |
| Hysteresis | typ. 0.5 mm | |
| Reverse polarity protection | reverse polarity tolerant | |
| Short-circuit protection | no | |
| Voltage drop | &le 6 V | |
| Operating current | 4 ... 100 mA | |
| Off-state current | 100 ... 200 µA typ. 160 µA | |
| Switching state indicator | LED, yellow | |
| Valve status indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 684 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| EAC conformity | TR CU 020/2011 | |
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| Ambient conditions | ||
| Ambient temperature | -40 ... 75 °C (-40 ... 167 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection (system side) | screw terminal , M20 x 1.5 cable gland | |
| Core cross-section (system side) | 1.5/2.5 mm2 flexible/rigid | |
| Connection (valve side) | 4-pin, M12 x 1 socket | |
| Housing material | rugged, translucent polycarbonate (PC) optimised for outdoor use | |
| Degree of protection | IP66 / IP67 / IP69K | |
| Tightening torque, housing screws | &le 2 Nm | |
| Tightening torque, cable gland | M20 x 1.5 max. 4 Nm M12 x 1 max. 3 Nm | |
| Tightening torque, stopping plug | 1 Nm | |
| General specifications | ||
|---|---|---|
| Switching function | 2 x normally open (NO) | |
| Output type | PNP | |
| Rated operating distance | 2.5 mm | |
| Installation | for non-flush mounting | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 2.05 mm | |
| Output type | 4-wire | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V | |
| Switching frequency | 0 ... 100 Hz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | all connections | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 100 mA | |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA | |
| No-load supply current | &le 25 mA | |
| Operating voltage indicator | LED, green | |
| Switching state indicator | LED, yellow | |
| Valve status indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 605 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| EAC conformity | TR CU 020/2011 | |
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| Ambient conditions | ||
| Ambient temperature | -40 ... 75 °C (-40 ... 167 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection (system side) | screw terminal , M20 x 1.5 cable gland | |
| Core cross-section (system side) | 1.5/2.5 mm2 flexible/rigid | |
| Connection (valve side) | 4-pin, M12 x 1 socket | |
| Housing material | rugged, translucent polycarbonate (PC) optimised for outdoor use | |
| Degree of protection | IP66 / IP67 / IP69K | |
| Tightening torque, housing screws | &le 2 Nm | |
| Tightening torque, cable gland | M20 x 1.5 max. 4 Nm M12 x 1 max. 3 Nm | |
| Tightening torque, stopping plug | 1 Nm | |
| General specifications | ||
|---|---|---|
| Switching function | 2 x normally open (NO) | |
| Output type | Two-wire | |
| Rated operating distance | 2.5 mm | |
| Installation | for non-flush mounting | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 2.05 mm | |
| Output type | 2x 2-wire | |
| Nominal ratings | ||
| Operating voltage | 6 ... 30 V | |
| Switching frequency | 0 ... 100 Hz | |
| Hysteresis | typ. 0.5 mm | |
| Reverse polarity protection | reverse polarity tolerant | |
| Short-circuit protection | no | |
| Voltage drop | &le 6 V | |
| Operating current | 4 ... 100 mA | |
| Off-state current | 100 ... 200 µA typ. 160 µA | |
| Switching state indicator | LED, yellow | |
| Valve status indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 684 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| EAC conformity | TR CU 020/2011 | |
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| Ambient conditions | ||
| Ambient temperature | -40 ... 75 °C (-40 ... 167 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection (system side) | screw terminal , M20 x 1.5 cable gland | |
| Core cross-section (system side) | 1.5/2.5 mm2 flexible/rigid | |
| Connection (valve side) | 4-pin, M12 x 1 socket | |
| Housing material | rugged, translucent polycarbonate (PC) optimised for outdoor use | |
| Degree of protection | IP66 / IP67 / IP69K | |
| Tightening torque, housing screws | &le 2 Nm | |
| Tightening torque, cable gland | M20 x 1.5 max. 4 Nm M12 x 1 max. 3 Nm | |
| Tightening torque, stopping plug | 1 Nm | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open/closed (NO/NC) programmable | |
| Output type | AS-Interface | |
| Rated operating distance | 30 mm | |
| Installation | non-flush | |
| Assured operating distance | 0 ... 24.3 mm | |
| Reduction factor rAl | 0.3 | |
| Reduction factor rCu | 0.3 | |
| Reduction factor r304 | 0.75 | |
| Reduction factor rBrass | 0.38 | |
| Slave type | A/B slave | |
| AS-Interface specification | V3.0 | |
| Required master specification | &ge V2.1 | |
| Nominal ratings | ||
| Operating voltage | 26.5 ... 31.9 V via AS-i bus system | |
| Switching frequency | 0 ... 100 Hz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | reverse polarity protected | |
| No-load supply current | &le 40 mA | |
| Operating voltage indicator | LED, green | |
| Switching state indicator | dual-LED, yellow | |
| Error indicator | dual-LED, red | |
| Functional safety related parameters | ||
| MTTFd | 1330 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | Connector M12 x 1 , 4-pin | |
| Housing material | PA | |
| Sensing face | PA | |
| Degree of protection | IP67 | |
| Mass | 210 g | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open/closed (NO/NC) programmable | |
| Output type | AS-Interface | |
| Rated operating distance | 40 mm | |
| Installation | non-flush | |
| Assured operating distance | 0 ... 32.4 mm | |
| Reduction factor rAl | 0.3 | |
| Reduction factor rCu | 0.3 | |
| Reduction factor r304 | 0.75 | |
| Slave type | Standard slave | |
| AS-Interface specification | V2.1 | |
| Required master specification | &ge V2.1 | |
| Nominal ratings | ||
| Operating voltage | 26.5 ... 31.9 V via AS-i bus system | |
| Switching frequency | 0 ... 50 Hz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | reverse polarity protected | |
| No-load supply current | &le 40 mA | |
| Operating voltage indicator | LED, green | |
| Switching state indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 1330 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | Connector M12 x 1 , 4-pin | |
| Housing material | PA | |
| Sensing face | PA | |
| Housing diameter | ||
| Degree of protection | IP69K | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open/closed (NO/NC) programmable | |
| Output type | AS-Interface | |
| Rated operating distance | 40 mm | |
| Installation | non-flush | |
| Assured operating distance | 0 ... 32.4 mm | |
| Reduction factor rAl | 0.3 | |
| Reduction factor rCu | 0.3 | |
| Reduction factor r304 | 0.75 | |
| Slave type | A/B slave | |
| AS-Interface specification | V3.0 | |
| Required master specification | &ge V2.1 | |
| Nominal ratings | ||
| Operating voltage | 26.5 ... 31.9 V via AS-i bus system | |
| Switching frequency | 0 ... 50 Hz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | reverse polarity protected | |
| No-load supply current | &le 25 mA | |
| Operating voltage indicator | LED, green | |
| Switching state indicator | LED, yellow | |
| Error indicator | LED, red | |
| Functional safety related parameters | ||
| MTTFd | 1330 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | Connector M12 x 1 , 4-pin | |
| Housing material | PA | |
| Sensing face | PA | |
| Degree of protection | IP69K | |
| Mass | 210 g | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open/closed (NO/NC) programmable | |
| Output type | AS-Interface | |
| Rated operating distance | 40 mm | |
| Installation | non-flush | |
| Assured operating distance | 0 ... 32.4 mm | |
| Actual operating distance | 36 ... 44 mm typ. 40 mm | |
| Reduction factor rAl | 0.5 | |
| Reduction factor rCu | 0.45 | |
| Reduction factor r304 | 0.85 | |
| Slave type | A/B slave | |
| AS-Interface specification | V3.0 | |
| Required master specification | &ge V2.1 | |
| Nominal ratings | ||
| Operating voltage | 26.5 ... 31.9 V via AS-i bus system | |
| Switching frequency | 0 ... 150 Hz | |
| Hysteresis | 1 ... 15 typ. 5 % | |
| Reverse polarity protection | reverse polarity protected | |
| No-load supply current | &le 25 mA | |
| Operating voltage indicator | LED, green | |
| Switching state indicator | LED, yellow | |
| Error indicator | LED, red | |
| Functional safety related parameters | ||
| MTTFd | 1330 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | screw terminals | |
| Information for connection | A maximum of two conductors with the same core cross section may be mounted on one terminal connection! tightening torque 1.2 Nm + 10 % | |
| Core cross-section | up to 2.5 mm2 | |
| Minimum core cross-section | without wire end ferrule 0.5 mm2 , with connector sleeves 0.34 mm2 | |
| Maximum core cross-section | without wire end ferrule 2.5 mm2 , with connector sleeves 1.5 mm2 | |
| Housing material | PA/metal with epoxy powder coating | |
| Sensing face | PBT | |
| Housing diameter | ||
| Degree of protection | IP68 / IP69K | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open/closed (NO/NC) programmable | |
| Output type | AS-Interface | |
| Rated operating distance | 2 mm | |
| Installation | flush | |
| Assured operating distance | 0 ... 1.62 mm | |
| Actual operating distance | 1.8 ... 2.2 mm typ. | |
| Reduction factor rAl | 0.23 | |
| Reduction factor rCu | 0.21 | |
| Reduction factor r304 | 0.7 | |
| Slave type | Standard slave | |
| AS-Interface specification | V2.1 | |
| Required master specification | &ge V2.1 | |
| Nominal ratings | ||
| Operating voltage | 26.5 ... 31.9 V via AS-i bus system | |
| Switching frequency | 0 ... 500 Hz | |
| Hysteresis | 1 ... 10 typ. 5 % | |
| Reverse polarity protection | reverse polarity protected | |
| No-load supply current | &le 25 mA | |
| Switching state indicator | dual-LED, yellow | |
| Error indicator | dual-LED, red | |
| Functional safety related parameters | ||
| MTTFd | 2140 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | Connector M12 x 1 , 4-pin | |
| Housing material | Stainless steel 1.4305 / AISI 303 | |
| Sensing face | PBT | |
| Housing diameter | 12 mm | |
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open/closed (NO/NC) programmable | |
| Output type | AS-Interface | |
| Rated operating distance | 4 mm | |
| Installation | flush | |
| Assured operating distance | 0 ... 3.24 mm | |
| Actual operating distance | 3.6 ... 4.4 mm typ. 4 mm | |
| Reduction factor rAl | 0.23 | |
| Reduction factor rCu | 0.21 | |
| Reduction factor r304 | 0.7 | |
| Slave type | Standard slave | |
| AS-Interface specification | V2.1 | |
| Required master specification | &ge V2.1 | |
| Nominal ratings | ||
| Operating voltage | 26.5 ... 31.9 V via AS-i bus system | |
| Switching frequency | 0 ... 500 Hz | |
| Hysteresis | 1 ... 15 typ. 5 % | |
| Reverse polarity protection | reverse polarity protected | |
| Voltage drop at IL | ||
| Voltage drop IL = 20 mA, switching element on | 3.4 ... 5 V typ. 4.3 V | |
| No-load supply current | &le 25 mA | |
| Switching state indicator | dual-LED, yellow | |
| Error indicator | dual-LED, red | |
| Functional safety related parameters | ||
| MTTFd | 2140 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | Connector M12 x 1 4-pin | |
| Housing material | Stainless steel 1.4305 / AISI 303 | |
| Sensing face | PBT | |
| Housing diameter | 12 mm | |
| Degree of protection | IP67 | |