| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | PNP | |
| Rated operating distance | 3 mm | |
| Installation | flush mountable | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 2.43 mm | |
| Actual operating distance | 2.7 ... 3.3 mm typ. | |
| Reduction factor rAl | 0.5 | |
| Reduction factor rCu | 0.4 | |
| Reduction factor r304 | 1 | |
| Reduction factor rSt37 | 1.2 | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V | |
| Switching frequency | 0 ... 500 Hz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | all connections | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 200 mA | |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C | |
| No-load supply current | &le 25 mA | |
| Operating voltage indicator | LED, green | |
| Switching state indicator | LED, yellow | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | Connector M12 x 1 , 4-pin | |
| Housing material | PBT | |
| Sensing face | PBT | |
| Degree of protection | IP67 | |
| Tightening torque, fastening screws | M5 x 25 : 2.7 Nm | |
| Note | Mounted on mechanical drive | |
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | PNP | |
| Rated operating distance | 3 mm | |
| Installation | flush mountable | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 2.43 mm | |
| Reduction factor rAl | 0.5 | |
| Reduction factor rCu | 0.4 | |
| Reduction factor r304 | 1 | |
| Reduction factor rSt37 | 1.1 | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V | |
| Switching frequency | 0 ... 500 Hz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | all connections | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 200 mA | |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C | |
| No-load supply current | &le 18 mA | |
| Operating voltage indicator | LED, green | |
| Switching state indicator | LED, yellow | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | Connector M12 x 1 , 4-pin | |
| Housing material | PBT | |
| Sensing face | PBT | |
| Degree of protection | IP67 | |
| Tightening torque, fastening screws | M5 x 25 : 2.7 Nm | |
| General specifications | ||
|---|---|---|
| Switching function | 2 x normally open (NO) | |
| Output type | PNP | |
| Rated operating distance | 3 mm | |
| Installation | flush mountable | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 2.43 mm | |
| Actual operating distance | 2.7 ... 3.3 mm typ. | |
| Reduction factor rAl | 0.5 | |
| Reduction factor rCu | 0.4 | |
| Reduction factor r304 | 1 | |
| Reduction factor rSt37 | 1.2 | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V DC | |
| Switching frequency | 0 ... 500 Hz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | all connections | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 100 mA | |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C | |
| No-load supply current | &le 25 mA | |
| Operating voltage indicator | LED, green | |
| Switching state indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 780 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection (system side) | PVC cable 5 m | |
| Core cross-section (system side) | 0.75 mm2 | |
| Housing material | PBT | |
| Sensing face | PBT | |
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | 2 x normally open (NO) | |
| Output type | PNP | |
| Rated operating distance | 3 mm | |
| Installation | flush mountable | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 2.43 mm | |
| Actual operating distance | 2.7 ... 3.3 mm typ. | |
| Reduction factor rAl | 0.5 | |
| Reduction factor rCu | 0.4 | |
| Reduction factor r304 | 1 | |
| Reduction factor rSt37 | 1.2 | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V DC | |
| Switching frequency | 0 ... 500 Hz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | all connections | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 100 mA | |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C | |
| No-load supply current | &le 25 mA | |
| Operating voltage indicator | LED, green | |
| Switching state indicator | LED, yellow | |
| Valve status indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 780 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection (system side) | PVC cable 5 m | |
| Core cross-section (system side) | 0.75 mm2 | |
| Connection (valve side) | PVC cable 0.5 m | |
| Core cross-section (valve side) | 0.75 mm2 | |
| Housing material | PBT | |
| Sensing face | PBT | |
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | 2 x normally open (NO) | |
| Output type | PNP | |
| Rated operating distance | 3 mm | |
| Installation | flush mountable | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 2.43 mm | |
| Actual operating distance | 2.7 ... 3.3 mm typ. | |
| Reduction factor rAl | 0.5 | |
| Reduction factor rCu | 0.4 | |
| Reduction factor r304 | 1 | |
| Reduction factor rSt37 | 1.2 | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V DC | |
| Switching frequency | 0 ... 500 Hz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | all connections | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 100 mA | |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C | |
| No-load supply current | &le 25 mA | |
| Operating voltage indicator | LED, green | |
| Switching state indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 780 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection (system side) | PVC cable with stainless steel (V4A) connector M12x1 , L = 2 m | |
| Housing material | PBT | |
| Sensing face | PBT | |
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | 2 x normally open (NO) | |
| Output type | PNP | |
| Rated operating distance | 3 mm | |
| Installation | flush mountable | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 2.43 mm | |
| Actual operating distance | 2.7 ... 3.3 mm typ. | |
| Reduction factor rAl | 0.5 | |
| Reduction factor rCu | 0.4 | |
| Reduction factor r304 | 1 | |
| Reduction factor rSt37 | 1.2 | |
| Output type | 3-wire | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V DC | |
| Switching frequency | 0 ... 500 Hz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | all connections | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 100 mA | |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C | |
| No-load supply current | &le 25 mA | |
| Operating voltage indicator | LED, green | |
| Switching state indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 780 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection (system side) | PVC cable with stainless steel (V4A) connector M12x1 , L = 1.5 m | |
| Housing material | PBT | |
| Sensing face | PBT | |
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | 2 x normally open (NO) | |
| Output type | PNP | |
| Rated operating distance | 3 mm | |
| Installation | flush mountable | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 2.43 mm | |
| Actual operating distance | 2.7 ... 3.3 mm typ. | |
| Reduction factor rAl | 0.5 | |
| Reduction factor rCu | 0.4 | |
| Reduction factor r304 | 1 | |
| Reduction factor rSt37 | 1.2 | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V DC | |
| Switching frequency | 0 ... 500 Hz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | all connections | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 100 mA | |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C | |
| No-load supply current | &le 25 mA | |
| Operating voltage indicator | LED, green | |
| Switching state indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 780 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| EAC conformity | TR CU 020/2011 | |
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection (system side) | 4-pin, M12 x 1 connector | |
| Housing material | PBT | |
| Sensing face | PBT | |
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | 2 x normally open (NO) | |
| Output type | PNP | |
| Rated operating distance | 3 mm | |
| Installation | flush mountable | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 2.43 mm | |
| Actual operating distance | 2.7 ... 3.3 mm typ. | |
| Reduction factor rAl | 0.5 | |
| Reduction factor rCu | 0.4 | |
| Reduction factor r304 | 1 | |
| Reduction factor rSt37 | 1.2 | |
| Output type | 3-wire | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V | |
| Switching frequency | 0 ... 500 Hz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | all connections | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 100 mA | |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C | |
| No-load supply current | &le 25 mA | |
| Operating voltage indicator | LED, green | |
| Switching state indicator | LED, yellow | |
| Approvals and certificates | ||
| UL approval | cULus Listed | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection (system side) | 4-pin, M12 x 1 connector | |
| Housing material | PBT | |
| Sensing face | PBT | |
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | 2 x normally open (NO) | |
| Output type | PNP | |
| Rated operating distance | 3 mm | |
| Installation | flush mountable | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 2.43 mm | |
| Reduction factor rAl | 0.5 | |
| Reduction factor r304 | 1 | |
| Reduction factor rSt37 | 1.2 | |
| Output type | 3-wire | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V DC | |
| Switching frequency | 0 ... 500 Hz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | all connections | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 100 mA | |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C | |
| No-load supply current | &le 25 mA | |
| Operating voltage indicator | LED, green | |
| Switching state indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 780 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection (system side) | Connector Rd24 x 1/8 , 4-pin | |
| Connection (valve side) | 5-pin, M12 x 1 socket | |
| Housing material | PBT | |
| Sensing face | PBT | |
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | 2 x normally open (NO) | |
| Output type | PNP | |
| Rated operating distance | 3 mm | |
| Installation | flush mountable | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 2.43 mm | |
| Actual operating distance | 2.7 ... 3.3 mm typ. | |
| Reduction factor rAl | 0.5 | |
| Reduction factor rCu | 0.4 | |
| Reduction factor r304 | 1 | |
| Reduction factor rSt37 | 1.2 | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V DC | |
| Switching frequency | 0 ... 500 Hz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | all connections | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 100 mA | |
| Off-state current | 0 ... 0.1 mA typ. 20 µA at 25 °C | |
| No-load supply current | &le 25 mA | |
| Operating voltage indicator | LED, green | |
| Switching state indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 780 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| EAC conformity | TR CU 020/2011 | |
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | Connector M18 x 1 , 4-pin | |
| Housing material | PBT | |
| Sensing face | PBT | |
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | 2 x normally open (NO) | |
| Rated operating distance | 3 mm | |
| Installation | flush mountable | |
| Output polarity | AC/DC | |
| Assured operating distance | 0 ... 2.43 mm | |
| Reduction factor rAl | 0.45 | |
| Reduction factor rCu | 0.38 | |
| Reduction factor r304 | 1 | |
| Reduction factor rSt37 | 1.04 | |
| Nominal ratings | ||
| Operating voltage | 20 ... 253 V AC/DC | |
| Switching frequency | 25 Hz | |
| Hysteresis | typ. 3 % | |
| Reverse polarity protection | yes | |
| Short-circuit protection | yes | |
| Voltage drop | &le 8 V | |
| Operating current | 4 ... 400 mA | |
| Off-state current | &le 1.7 mA | |
| Operating voltage indicator | LED, green | |
| Switching state indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 529 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| Protection class | II | |
| Rated insulation voltage | 253 V | |
| Rated impulse withstand voltage | 4 kV | |
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 5 m | |
| Core cross-section | 0.5 mm2 | |
| Housing material | PBT | |
| Sensing face | PBT | |
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | 2 x normally open (NO) | |
| Rated operating distance | 3 mm | |
| Installation | flush mountable | |
| Output polarity | AC/DC | |
| Assured operating distance | 0 ... 2.43 mm | |
| Reduction factor rAl | 0.45 | |
| Reduction factor rCu | 0.38 | |
| Reduction factor r304 | 1 | |
| Reduction factor rSt37 | 1.04 | |
| Nominal ratings | ||
| Operating voltage | 20 ... 253 V AC/DC | |
| Switching frequency | 25 Hz | |
| Hysteresis | typ. 3 % | |
| Reverse polarity protection | yes | |
| Short-circuit protection | yes | |
| Voltage drop | &le 8 V | |
| Operating current | 4 ... 400 mA | |
| Off-state current | &le 1.7 mA | |
| Operating voltage indicator | LED, green | |
| Switching state indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 529 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| Protection class | II | |
| Rated insulation voltage | 253 V | |
| Rated impulse withstand voltage | 4 kV | |
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | Connector M18 x 1 , 4-pin | |
| Housing material | PBT | |
| Sensing face | PBT | |
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | 2 x normally open (NO) | |
| Output type | Two-wire | |
| Rated operating distance | 3 mm | |
| Installation | flush mountable | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 2.43 mm | |
| Actual operating distance | 2.7 ... 3.3 mm typ. 3 mm | |
| Reduction factor rAl | 0.5 | |
| Reduction factor rCu | 0.4 | |
| Reduction factor r304 | 1 | |
| Reduction factor rSt37 | 1.1 | |
| Output type | 4-wire | |
| Nominal ratings | ||
| Operating voltage | 6 ... 60 V DC | |
| Switching frequency | 0 ... 500 Hz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | reverse polarity tolerant | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 5.5 V | |
| Operating current | 4 ... 100 mA | |
| Lowest operating current | 4 mA | |
| Off-state current | 0.5 ... 0.9 mA typ. 0.65 mA | |
| Switching state indicator | LED, yellow | |
| Limit data | ||
| Tightening torque, fastening screws | 0.4 Nm | |
| Functional safety related parameters | ||
| MTTFd | 570 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection (system side) | PVC cable 5 m | |
| Core cross-section (system side) | 0.75 mm2 | |
| Housing material | PBT | |
| Sensing face | PBT | |
| Degree of protection | IP67 | |
| Mass | 196 g | |
| General specifications | ||
|---|---|---|
| Switching function | 2 x normally open (NO) | |
| Output type | Two-wire | |
| Rated operating distance | 3 mm | |
| Installation | flush mountable | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 2.43 mm | |
| Actual operating distance | 2.7 ... 3.3 mm typ. | |
| Reduction factor rAl | 0.5 | |
| Reduction factor rCu | 0.4 | |
| Reduction factor r304 | 1 | |
| Reduction factor rSt37 | 1.1 | |
| Nominal ratings | ||
| Operating voltage | 6 ... 60 V | |
| Switching frequency | 0 ... 500 Hz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | reverse polarity tolerant | |
| Short-circuit protection | no | |
| Voltage drop | &le 6 V | |
| Operating current | 4 ... 100 mA | |
| Lowest operating current | 4 mA | |
| Off-state current | 0 ... 1 mA typ. 0.7 mA | |
| Switching state indicator | LED, yellow | |
| Limit data | ||
| Tightening torque, fastening screws | 0.4 Nm | |
| Functional safety related parameters | ||
| MTTFd | 590 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | Certified by China Compulsory Certification (CCC) | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection (system side) | 10 m, PVC cable | |
| Core cross-section (system side) | 0.75 mm2 | |
| Housing material | PBT | |
| Sensing face | PBT | |
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | 2 x normally open (NO) | |
| Output type | Two-wire | |
| Rated operating distance | 3 mm | |
| Installation | flush mountable | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 2.43 mm | |
| Actual operating distance | 2.7 ... 3.3 mm typ. 3 mm | |
| Reduction factor rAl | 0.5 | |
| Reduction factor rCu | 0.4 | |
| Reduction factor r304 | 1 | |
| Reduction factor rSt37 | 1.1 | |
| Output type | 4-wire | |
| Nominal ratings | ||
| Operating voltage | 6 ... 60 V DC | |
| Switching frequency | 0 ... 500 Hz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | reverse polarity tolerant | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 5.5 V | |
| Operating current | 4 ... 100 mA | |
| Lowest operating current | 4 mA | |
| Off-state current | 0.5 ... 0.9 mA typ. 0.65 mA | |
| Switching state indicator | LED, yellow | |
| Limit data | ||
| Tightening torque, fastening screws | 0.4 Nm | |
| Functional safety related parameters | ||
| MTTFd | 570 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection (system side) | PVC cable 5 m | |
| Core cross-section (system side) | 0.75 mm2 | |
| Housing material | PBT | |
| Sensing face | PBT | |
| Degree of protection | IP67 | |
| Mass | 642 g | |
| General specifications | ||
|---|---|---|
| Switching function | 2 x normally open (NO) | |
| Output type | Two-wire | |
| Rated operating distance | 3 mm | |
| Installation | flush mountable | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 2.43 mm | |
| Actual operating distance | 2.7 ... 3.3 mm typ. 3 mm | |
| Reduction factor rAl | 0.5 | |
| Reduction factor rCu | 0.4 | |
| Reduction factor r304 | 1 | |
| Reduction factor rSt37 | 1.1 | |
| Output type | 4-wire | |
| Nominal ratings | ||
| Operating voltage | 6 ... 60 V DC | |
| Switching frequency | 0 ... 500 Hz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | reverse polarity tolerant | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 5.5 V | |
| Operating current | 4 ... 100 mA | |
| Lowest operating current | 4 mA | |
| Off-state current | 0.5 ... 0.9 mA typ. 0.65 mA | |
| Switching state indicator | LED, yellow | |
| Limit data | ||
| Tightening torque, fastening screws | 0.4 Nm | |
| Functional safety related parameters | ||
| MTTFd | 570 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection (system side) | 4-pin, M12 x 1 connector | |
| Housing material | PBT | |
| Sensing face | PBT | |
| Degree of protection | IP67 | |
| Mass | 85 g | |
| General specifications | ||
|---|---|---|
| Switching function | 2 x normally open (NO) | |
| Output type | Two-wire | |
| Rated operating distance | 3 mm | |
| Installation | flush mountable | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 2.43 mm | |
| Actual operating distance | 2.7 ... 3.3 mm typ. | |
| Reduction factor rAl | 0.5 | |
| Reduction factor rCu | 0.4 | |
| Reduction factor r304 | 1 | |
| Reduction factor rSt37 | 1.1 | |
| Nominal ratings | ||
| Operating voltage | 6 ... 60 V DC | |
| Switching frequency | 0 ... 500 Hz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | reverse polarity tolerant | |
| Short-circuit protection | no | |
| Voltage drop | &le 6 V | |
| Operating current | 4 ... 100 mA | |
| Lowest operating current | 4 mA | |
| Off-state current | 0 ... 1 mA typ. 0.7 mA | |
| Switching state indicator | LED, yellow | |
| Valve status indicator | LED, yellow | |
| Limit data | ||
| Tightening torque, fastening screws | 0.4 Nm | |
| Functional safety related parameters | ||
| MTTFd | 590 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection (system side) | Connector Rd24 x 1/8 , 4-pin | |
| Connection (valve side) | 5-pin, M12 x 1 socket | |
| Housing material | PBT | |
| Sensing face | PBT | |
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | 2 x normally open (NO) | |
| Output type | Two-wire | |
| Rated operating distance | 3 mm | |
| Installation | flush mountable | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 2.43 mm | |
| Actual operating distance | 2.7 ... 3.3 mm typ. | |
| Reduction factor rAl | 0.5 | |
| Reduction factor rCu | 0.4 | |
| Reduction factor r304 | 1 | |
| Reduction factor rSt37 | 1.1 | |
| Nominal ratings | ||
| Operating voltage | 6 ... 60 V | |
| Switching frequency | 0 ... 500 Hz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | reverse polarity tolerant | |
| Short-circuit protection | no | |
| Voltage drop | &le 6 V | |
| Operating current | 4 ... 100 mA | |
| Lowest operating current | 4 mA | |
| Off-state current | 0 ... 1 mA typ. 0.7 mA | |
| Switching state indicator | LED, yellow | |
| Valve status indicator | LED, yellow | |
| Limit data | ||
| Tightening torque, fastening screws | 0.4 Nm | |
| Functional safety related parameters | ||
| MTTFd | 590 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection (system side) | V16-connector | |
| Connection (valve side) | V16-connector | |
| Housing material | PBT | |
| Sensing face | PBT | |
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | 2 x normally open (NO) | |
| Output type | Two-wire | |
| Rated operating distance | 3 mm | |
| Installation | flush mountable | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 2.43 mm | |
| Actual operating distance | 2.7 ... 3.3 mm typ. 3 mm | |
| Reduction factor rAl | 0.5 | |
| Reduction factor rCu | 0.4 | |
| Reduction factor r304 | 1 | |
| Reduction factor rSt37 | 1.1 | |
| Output type | 4-wire | |
| Nominal ratings | ||
| Operating voltage | 6 ... 60 V DC | |
| Switching frequency | 0 ... 500 Hz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | reverse polarity tolerant | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 5.5 V | |
| Operating current | 4 ... 100 mA | |
| Lowest operating current | 4 mA | |
| Off-state current | 0.5 ... 0.9 mA typ. 0.65 mA | |
| Switching state indicator | LED, yellow | |
| Limit data | ||
| Tightening torque, fastening screws | 0.4 Nm | |
| Functional safety related parameters | ||
| MTTFd | 570 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | Connector Rd24 x 1/8 , 4-pin | |
| Housing material | PBT | |
| Sensing face | PBT | |
| Degree of protection | IP67 | |
| Mass | 113 g | |
| General specifications | ||
|---|---|---|
| Switching function | 2 x normally open (NO) | |
| Output type | Two-wire | |
| Rated operating distance | 3 mm | |
| Installation | flush mountable | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 2.43 mm | |
| Actual operating distance | 2.7 ... 3.3 mm typ. 3 mm | |
| Reduction factor rAl | 0.5 | |
| Reduction factor rCu | 0.4 | |
| Reduction factor r304 | 1 | |
| Reduction factor rSt37 | 1.1 | |
| Output type | 4-wire | |
| Nominal ratings | ||
| Operating voltage | 6 ... 60 V DC | |
| Switching frequency | 0 ... 500 Hz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | reverse polarity tolerant | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 5.5 V | |
| Operating current | 4 ... 100 mA | |
| Lowest operating current | 4 mA | |
| Off-state current | 0.5 ... 0.9 mA typ. 0.65 mA | |
| Switching state indicator | LED, yellow | |
| Limit data | ||
| Tightening torque, fastening screws | 0.4 Nm | |
| Functional safety related parameters | ||
| MTTFd | 570 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | Connector M18 x 1 , 4-pin | |
| Housing material | PBT | |
| Sensing face | PBT | |
| Degree of protection | IP67 | |
| Mass | 94 g | |
| General specifications | ||
|---|---|---|
| Switching function | 2 x normally open (NO) | |
| Output type | PNP | |
| Rated operating distance | 3 mm | |
| Installation | flush mountable | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 2.43 mm | |
| Actual operating distance | 2.7 ... 3.3 mm typ. | |
| Reduction factor rAl | 0.5 | |
| Reduction factor rCu | 0.4 | |
| Reduction factor r304 | 1 | |
| Reduction factor rSt37 | 1.2 | |
| Reduction factor rBrass | ||
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V | |
| Switching frequency | 0 ... 500 Hz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | all connections | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 100 mA | |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA | |
| No-load supply current | &le 25 mA | |
| Operating voltage indicator | LED, green | |
| Switching state indicator | LED, yellow | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection (system side) | Cage tension spring terminals | |
| Core cross-section (system side) | 1.5/2.5 mm2 flexible/rigid | |
| Housing material | PBT | |
| Sensing face | PBT | |
| Degree of protection | IP67 | |
| Tightening torque, housing screws | 1 Nm | |
| Tightening torque, cable gland | M20 x 1.5 max. 7 Nm | |
| General specifications | ||
|---|---|---|
| Switching function | 2 x normally open (NO) | |
| Output type | PNP | |
| Rated operating distance | 3 mm | |
| Installation | flush mountable | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 2.43 mm | |
| Actual operating distance | 2.7 ... 3.3 mm typ. | |
| Reduction factor rAl | 0.5 | |
| Reduction factor rCu | 0.4 | |
| Reduction factor r304 | 1 | |
| Reduction factor rSt37 | 1.2 | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V DC | |
| Switching frequency | 0 ... 500 Hz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | all connections | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 100 mA | |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA | |
| No-load supply current | &le 25 mA | |
| Operating voltage indicator | LED, green | |
| Switching state indicator | LED, yellow | |
| Valve status indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 780 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection (system side) | Cage tension spring terminals | |
| Core cross-section (system side) | 1.5/2.5 mm2 flexible/rigid | |
| Connection (valve side) | Cage tension spring terminals | |
| Core cross-section (valve side) | 1.5/2.5 mm2 flexible/rigid | |
| Housing material | PBT | |
| Sensing face | PBT | |
| Degree of protection | IP67 | |
| Tightening torque, housing screws | 1 Nm | |
| Tightening torque, cable gland | M20 x 1.5 max. 7 Nm M12 x 1.5 max. 3 Nm | |
| General specifications | ||
|---|---|---|
| Switching function | 2 x normally open (NO) | |
| Output type | PNP | |
| Rated operating distance | 3 mm | |
| Installation | flush mountable | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 2.43 mm | |
| Actual operating distance | 2.7 ... 3.3 mm typ. | |
| Reduction factor rAl | 0.5 | |
| Reduction factor rCu | 0.4 | |
| Reduction factor r304 | 1 | |
| Reduction factor rSt37 | 1.2 | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V DC | |
| Switching frequency | 0 ... 500 Hz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | all connections | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 100 mA | |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA | |
| No-load supply current | &le 25 mA | |
| Operating voltage indicator | LED, green | |
| Switching state indicator | LED, yellow | |
| Valve status indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 780 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection (system side) | Cage tension spring terminals | |
| Core cross-section (system side) | 1.5/2.5 mm2 flexible/rigid | |
| Connection (valve side) | 4-pin, M12 x 1 socket | |
| Housing material | PBT | |
| Sensing face | PBT | |
| Degree of protection | IP67 | |
| Tightening torque, housing screws | 1 Nm | |
| Tightening torque, cable gland | M20 x 1.5 max. 7 Nm | |
| General specifications | ||
|---|---|---|
| Switching function | 2 x normally open (NO) | |
| Output type | PNP | |
| Rated operating distance | 3 mm | |
| Installation | flush mountable | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 2.43 mm | |
| Actual operating distance | 2.7 ... 3.3 mm typ. | |
| Reduction factor rAl | 0.5 | |
| Reduction factor rCu | 0.4 | |
| Reduction factor r304 | 1 | |
| Reduction factor rSt37 | 1.2 | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V | |
| Switching frequency | 0 ... 500 Hz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | all connections | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 100 mA | |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA | |
| No-load supply current | &le 25 mA | |
| Operating voltage indicator | LED, green | |
| Switching state indicator | LED, yellow | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection (system side) | Screw terminals, tightening torque min. 0.5 Nm Stripped length 7 mm | |
| Core cross-section (system side) | rigid: 0.14 ... 2.5 mm2 flexible: 0.14 ... 1.5 mm2 flexible with core-end sleeve: 0.25 ... 1.5 mm2 | |
| Housing material | PBT | |
| Sensing face | PBT | |
| Degree of protection | IP67 | |
| Tightening torque, housing screws | 1 Nm | |
| Tightening torque, cable gland | M20 x 1.5 max. 7 Nm | |
| General specifications | ||
|---|---|---|
| Switching function | 2 x normally open (NO) | |
| Output type | Two-wire | |
| Rated operating distance | 3 mm | |
| Installation | flush mountable | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 2.43 mm | |
| Actual operating distance | 2.7 ... 3.3 mm typ. 3 mm | |
| Reduction factor rAl | 0.5 | |
| Reduction factor rCu | 0.4 | |
| Reduction factor r304 | 1 | |
| Reduction factor rSt37 | 1.1 | |
| Output type | 4-wire | |
| Nominal ratings | ||
| Operating voltage | 6 ... 60 V DC | |
| Switching frequency | 0 ... 500 Hz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | reverse polarity tolerant | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 5.5 V | |
| Operating current | 4 ... 100 mA | |
| Lowest operating current | 4 mA | |
| Off-state current | 0.5 ... 0.9 mA typ. 0.65 mA | |
| Switching state indicator | LED, yellow | |
| Limit data | ||
| Tightening torque, fastening screws | 0.4 Nm | |
| Functional safety related parameters | ||
| MTTFd | 570 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection (system side) | Cage tension spring terminals | |
| Core cross-section (system side) | 1.5/2.5 mm2 flexible/rigid | |
| Housing material | PBT | |
| Sensing face | PBT | |
| Degree of protection | IP67 | |
| Mass | 174 g | |
| Tightening torque, housing screws | 1 Nm | |
| Tightening torque, cable gland | M20 x 1.5 max. 7 Nm | |
| General specifications | ||
|---|---|---|
| Switching function | 2 x normally open (NO) | |
| Output type | Two-wire | |
| Rated operating distance | 3 mm | |
| Installation | flush mountable | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 2.43 mm | |
| Actual operating distance | 2.7 ... 3.3 mm typ. 3 mm | |
| Reduction factor rAl | 0.5 | |
| Reduction factor rCu | 0.4 | |
| Reduction factor r304 | 1 | |
| Reduction factor rSt37 | 1.1 | |
| Output type | 4-wire | |
| Nominal ratings | ||
| Operating voltage | 6 ... 60 V DC | |
| Switching frequency | 0 ... 500 Hz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | reverse polarity tolerant | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 5.5 V | |
| Operating current | 4 ... 100 mA | |
| Lowest operating current | 4 mA | |
| Off-state current | 0.5 ... 0.9 mA typ. 0.65 mA | |
| Switching state indicator | LED, yellow | |
| Valve status indicator | LED, yellow | |
| Limit data | ||
| Tightening torque, fastening screws | 0.4 Nm | |
| Functional safety related parameters | ||
| MTTFd | 570 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection (system side) | Cage tension spring terminals | |
| Core cross-section (system side) | 1.5/2.5 mm2 flexible/rigid | |
| Connection (valve side) | Cage tension spring terminals | |
| Core cross-section (valve side) | 1.5/2.5 mm2 flexible/rigid | |
| Housing material | PBT | |
| Sensing face | PBT | |
| Degree of protection | IP67 | |
| Mass | 180 g | |
| Tightening torque, housing screws | 1 Nm | |
| Tightening torque, cable gland | M20 x 1.5 max. 7 Nm M12 x 1.5 max. 3 Nm | |
| General specifications | ||
|---|---|---|
| Switching function | 2 x normally open (NO) | |
| Output type | Two-wire | |
| Rated operating distance | 3 mm | |
| Installation | flush mountable | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 2.43 mm | |
| Actual operating distance | 2.7 ... 3.3 mm typ. 3 mm | |
| Reduction factor rAl | 0.5 | |
| Reduction factor rCu | 0.4 | |
| Reduction factor r304 | 1 | |
| Reduction factor rSt37 | 1.1 | |
| Output type | 4-wire | |
| Nominal ratings | ||
| Operating voltage | 6 ... 60 V DC | |
| Switching frequency | 0 ... 500 Hz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | reverse polarity tolerant | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 5.5 V | |
| Operating current | 4 ... 100 mA | |
| Lowest operating current | 4 mA | |
| Off-state current | 0.5 ... 0.9 mA typ. 0.65 mA | |
| Operating voltage indicator | LED, green | |
| Switching state indicator | LED, yellow | |
| Valve status indicator | LED, yellow | |
| Limit data | ||
| Tightening torque, fastening screws | 0.4 Nm | |
| Functional safety related parameters | ||
| MTTFd | 570 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection (system side) | Cage tension spring terminals | |
| Core cross-section (system side) | 1.5/2.5 mm2 flexible/rigid | |
| Connection (valve side) | 4-pin, M12 x 1 socket | |
| Housing material | PBT | |
| Sensing face | PBT | |
| Degree of protection | IP67 | |
| Mass | 177 g | |
| Tightening torque, housing screws | 1 Nm | |
| Tightening torque, cable gland | M20 x 1.5 max. 7 Nm | |
| General specifications | ||
|---|---|---|
| Switching function | 2 x normally open (NO) | |
| Output type | PNP | |
| Rated operating distance | 2.5 mm | |
| Installation | for non-flush mounting | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 2.05 mm | |
| Output type | 4-wire | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V | |
| Switching frequency | 0 ... 100 Hz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | all connections | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 100 mA | |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA | |
| No-load supply current | &le 25 mA | |
| Operating voltage indicator | LED, green | |
| Switching state indicator | LED, yellow | |
| Valve status indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 490 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| EAC conformity | TR CU 020/2011 | |
| Ambient conditions | ||
| Ambient temperature | -40 ... 75 °C (-40 ... 167 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection (system side) | screw terminal , M20 x 1.5 cable gland | |
| Core cross-section (system side) | 1.5/2.5 mm2 flexible/rigid | |
| Housing material | rugged, translucent polycarbonate (PC) optimised for outdoor use | |
| Degree of protection | IP66 / IP68 / IP69 | |
| Tightening torque, housing screws | &le 2 Nm | |
| Tightening torque, cable gland | max. 4 Nm | |
| Tightening torque, stopping plug | 1 Nm | |
| General specifications | ||
|---|---|---|
| Switching function | 2 x normally open (NO) | |
| Output type | PNP | |
| Rated operating distance | 2.5 mm | |
| Installation | for non-flush mounting | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 2.05 mm | |
| Output type | 4-wire | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V | |
| Switching frequency | 0 ... 100 Hz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | all connections | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 100 mA | |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA | |
| No-load supply current | &le 25 mA | |
| Operating voltage indicator | LED, green | |
| Switching state indicator | LED, yellow | |
| Valve status indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 605 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| EAC conformity | TR CU 020/2011 | |
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| Ambient conditions | ||
| Ambient temperature | -40 ... 75 °C (-40 ... 167 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection (system side) | screw terminal , M20 x 1.5 cable gland | |
| Core cross-section (system side) | 1.5/2.5 mm2 flexible/rigid | |
| Connection (valve side) | 4-pin, M12 x 1 socket | |
| Housing material | rugged, translucent polycarbonate (PC) optimised for outdoor use | |
| Degree of protection | IP66 / IP67 / IP69K | |
| Tightening torque, housing screws | &le 2 Nm | |
| Tightening torque, cable gland | M20 x 1.5 max. 4 Nm M12 x 1 max. 3 Nm | |
| Tightening torque, stopping plug | 1 Nm | |
| General specifications | ||
|---|---|---|
| Switching function | 2 x normally open (NO) | |
| Output type | PNP | |
| Rated operating distance | 2.5 mm | |
| Installation | for non-flush mounting | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 2.05 mm | |
| Output type | 4-wire | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V | |
| Switching frequency | 0 ... 100 Hz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | all connections | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 100 mA | |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA | |
| No-load supply current | &le 25 mA | |
| Operating voltage indicator | LED, green | |
| Switching state indicator | LED, yellow | |
| Valve status indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 605 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| EAC conformity | TR CU 020/2011 | |
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| Ambient conditions | ||
| Ambient temperature | -40 ... 75 °C (-40 ... 167 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection (system side) | screw terminal , 1/2" NPT cable gland | |
| Core cross-section (system side) | 1.5/2.5 mm2 flexible/rigid | |
| Connection (valve side) | 4-pin, M12 x 1 socket | |
| Housing material | rugged, translucent polycarbonate (PC) optimised for outdoor use | |
| Degree of protection | IP66 / IP67 / IP69K | |
| Tightening torque, housing screws | &le 2 Nm | |
| Tightening torque, cable gland | Refer to NEC (National Electrical Code), hand-tight then wrench tightened (max. 3 turns) | |
| Tightening torque, stopping plug | 1 Nm | |
Товаров: 0
На сумму: 0