General specifications | ||
---|---|---|
Switching function | complementary | |
Output type | PNP | |
Rated operating distance | 40 mm | |
Installation | non-flush | |
Output polarity | DC | |
Assured operating distance | 0 ... 32.4 mm | |
Nominal ratings | ||
Installation conditions | ||
B | 40 mm | |
C | 80 mm | |
F | 120 mm | |
Operating voltage | 10 ... 60 V DC | |
Switching frequency | 0 ... 10 Hz | |
Hysteresis | 3 ... 20 % 10 % typical | |
Reverse polarity protection | reverse polarity protected | |
Short-circuit protection | pulsing | |
Voltage drop | &le 3 V | |
Operating current | 0 ... 200 mA | |
No-load supply current | &le 20 mA | |
Switching state indicator | LED, yellow | |
Indicators/operating means | ||
Potentiometer | sensitivity adjustment | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Mechanical specifications | ||
Connection type | screw terminals | |
Core cross-section | up to 2.5 mm2 | |
Housing material | POM / metal | |
Sensing face | POM | |
Degree of protection | IP65 |
General specifications | ||
---|---|---|
Switching function | complementary | |
Output type | PNP | |
Rated operating distance | 40 mm | |
Installation | non-flush | |
Output polarity | DC | |
Assured operating distance | 0 ... 32.4 mm | |
Nominal ratings | ||
Operating voltage | 10 ... 60 V DC | |
Switching frequency | 0 ... 10 Hz | |
Hysteresis | 3 ... 20 % 10 % typical | |
Reverse polarity protection | reverse polarity protected | |
Short-circuit protection | pulsing | |
Voltage drop | &le 3 V | |
Operating current | 0 ... 200 mA | |
No-load supply current | &le 20 mA | |
Indicators/operating means | ||
LED yellow | indication switching state | |
Potentiometer | sensitivity adjustment | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Mechanical specifications | ||
Connection type | Connector M12 x 1 , 4-pin | |
Housing material | POM / metal | |
Sensing face | POM | |
Degree of protection | IP65 |
General specifications | ||
---|---|---|
Switching function | Normally open/closed (NO/NC) | |
Output type | Two-wire | |
Rated operating distance | 40 mm | |
Installation | non-flush | |
Output polarity | AC | |
Assured operating distance | 0 ... 32.4 mm | |
Nominal ratings | ||
Installation conditions | ||
A | 30 mm | |
B | 40 mm | |
C | 80 mm | |
F | 120 mm | |
Operating voltage | 20 ... 250 V AC 1) | |
Switching frequency | 0 ... 10 Hz | |
Reverse polarity protection | reverse polarity tolerant | |
Voltage drop | &le 5 V AC | |
Momentary current (20 ms, 0.1 Hz) | 0 ... 4000 mA | |
Operating current | 10 ... 500 mA | |
Off-state current | 0 ... 2.5 mA typ. | |
Switching state indicator | LED, red | |
Indicators/operating means | ||
Potentiometer | sensitivity adjustment | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Mechanical specifications | ||
Connection type | screw terminals | |
Information for connection | A maximum of two conductors with the same core cross section may be mounted on one terminal connection! tightening torque 1.2 Nm + 10 % | |
Core cross-section | up to 2.5 mm2 | |
Minimum core cross-section | without wire end ferrule 0.5 mm2 , with connector sleeves 0.34 mm2 | |
Maximum core cross-section | without wire end ferrule 2.5 mm2 , with connector sleeves 1.5 mm2 | |
Housing material | PBT/POM | |
Sensing face | PBT/POM | |
Degree of protection | IP65 | |
Note | 1) In the temperature range below 0 °C, permissible operating voltage Ub 80...253 V Safety fuse &le 1.5 A (quick-blow) according to IEC 60127-2 Sheet 1 Recommendation: after a short circuit, check that the device is functioning correctly. |
General specifications | ||
---|---|---|
Switching function | Normally open/closed (NO/NC) | |
Output type | Two-wire | |
Rated operating distance | 40 mm | |
Installation | non-flush | |
Output polarity | AC | |
Assured operating distance | 0 ... 32.4 mm | |
Nominal ratings | ||
Installation conditions | ||
B | 40 mm | |
C | 80 mm | |
F | 120 mm | |
Operating voltage | 20 ... 250 V AC | |
Switching frequency | 0 ... 10 Hz | |
Short-circuit protection | no | |
Voltage drop | &le 5 V AC | |
Momentary current (20 ms, 0.1 Hz) | 0 ... 4000 mA | |
Operating current | 10 ... 500 mA | |
Off-state current | 0 ... 2.5 mA typ. | |
Indicators/operating means | ||
LED red | indication switching state | |
Potentiometer | sensitivity adjustment | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Mechanical specifications | ||
Connection type | screw terminals | |
Information for connection | A maximum of two conductors with the same core cross section may be mounted on one terminal connection! tightening torque 1.2 Nm + 10 % | |
Core cross-section | up to 2.5 mm2 | |
Minimum core cross-section | without wire end ferrule 0.5 mm2 , with connector sleeves 0.34 mm2 | |
Maximum core cross-section | without wire end ferrule 2.5 mm2 , with connector sleeves 1.5 mm2 | |
Housing material | PBT/POM | |
Sensing face | PBT/POM | |
Degree of protection | IP65 | |
Note | 1) In the temperature range below 0 °C, permissible operating voltage Ub 80...253 V Safety fuse &le 1.5 A (quick-blow) according to IEC 60127-2 Sheet 1 Recommendation: after a short circuit, check that the device is functioning correctly. |
General specifications | ||
---|---|---|
Switching function | Normally open/closed (NO/NC) | |
Output type | Two-wire | |
Rated operating distance | 40 mm | |
Installation | non-flush | |
Output polarity | AC | |
Assured operating distance | 0 ... 32.4 mm | |
Nominal ratings | ||
Installation conditions | ||
B | 40 mm | |
C | 80 mm | |
F | 120 mm | |
Operating voltage | 20 ... 250 V AC 1) | |
Switching frequency | 0 ... 10 Hz | |
Reverse polarity protection | reverse polarity tolerant | |
Voltage drop | &le 5 V AC | |
Momentary current (20 ms, 0.1 Hz) | 0 ... 4000 mA | |
Operating current | 10 ... 500 mA | |
Off-state current | 0 ... 2.5 mA typ. | |
Switching state indicator | LED, red | |
Indicators/operating means | ||
Potentiometer | sensitivity adjustment | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Mechanical specifications | ||
Connection type | screw terminals | |
Information for connection | A maximum of two conductors with the same core cross section may be mounted on one terminal connection! tightening torque 1.2 Nm + 10 % | |
Core cross-section | up to 2.5 mm2 | |
Minimum core cross-section | without wire end ferrule 0.5 mm2 , with connector sleeves 0.34 mm2 | |
Maximum core cross-section | without wire end ferrule 2.5 mm2 , with connector sleeves 1.5 mm2 | |
Housing material | PBT/POM | |
Sensing face | PBT/POM | |
Degree of protection | IP65 | |
Note | 1) In the temperature range below 0 °C, permissible operating voltage Ub 80...253 V Safety fuse &le 1.5 A (quick-blow) according to IEC 60127-2 Sheet 1 Recommendation: after a short circuit, check that the device is functioning correctly. |
General specifications | ||
---|---|---|
Switching function | Normally open (NO) | |
Output type | Two-wire | |
Rated operating distance | 40 mm | |
Installation | non-flush | |
Output polarity | AC | |
Assured operating distance | 0 ... 32.4 mm | |
Nominal ratings | ||
Installation conditions | ||
B | 40 mm | |
C | 80 mm | |
F | 120 mm | |
Operating voltage | 20 ... 250 V AC | |
Switching frequency | 0 ... 10 Hz | |
Hysteresis | 3 ... 20 % ( 10 % typical ) | |
Reverse polarity protection | no | |
Short-circuit protection | no | |
Voltage drop | &le 5 V AC | |
Momentary current (20 ms, 0.1 Hz) | 0 ... 4000 mA | |
Operating current | 10 ... 500 mA | |
Off-state current | 0 ... 2.5 mA typ. | |
Indicators/operating means | ||
LED green | Power on | |
LED red | Output status | |
Potentiometer | sensitivity adjustment | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Mechanical specifications | ||
Connection type | V12 connector | |
Housing material | PBT | |
Sensing face | PBT | |
Degree of protection | IP65 | |
Note | 1) In the temperature range below 0 °C, permissible operating voltage Ub 80...253 V Safety fuse &le 1.5 A (quick-blow) according to IEC 60127-2 Sheet 1 Recommendation: after a short circuit, check that the device is functioning correctly. |
General specifications | ||
---|---|---|
Switching function | Normally open (NO) | |
Output type | NAMUR | |
Rated operating distance | 6 mm | |
Installation | non-flush | |
Assured operating distance | 0 ... 4.32 mm | |
Output type | 2-wire | |
Nominal ratings | ||
Installation conditions | ||
A | 40 mm | |
B | 80 mm | |
C | 20 mm | |
F | 120 mm | |
Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) | |
Operating voltage | 7 ... 12 V | |
Switching frequency | 0 ... 1 Hz | |
Current consumption | ||
Measuring plate not detected | &le 1 mA | |
Measuring plate detected | &ge 2.4 mA | |
Functional safety related parameters | ||
MTTFd | 5030 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Compliance with standards and directives | ||
Standard conformity | ||
NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
Approvals and certificates | ||
FM approval | ||
Control drawing | 116-0165 | |
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Mechanical specifications | ||
Connection type | cable PVC , 2 m | |
Core cross-section | 0.75 mm2 | |
Housing material | PBT | |
Sensing face | PBT | |
Degree of protection | IP68 | |
Cable | ||
Bending radius | > 10 x cable diameter | |
General information | ||
Use in the hazardous area | see instruction manuals | |
Category | 1G 2G 1D |
General specifications | ||
---|---|---|
Switching function | Normally open (NO) | |
Output type | NAMUR | |
Rated operating distance | 11 ... 12.5 mm | |
Installation | non-flush | |
Assured operating distance | 0 ... 8.8 mm | |
Output type | 2-wire | |
Nominal ratings | ||
Installation conditions | ||
A | 40 mm | |
B | 80 mm | |
C | 20 mm | |
F | 120 mm | |
Nominal voltage | 8 V | |
Operating voltage | 7 ... 12 V | |
Switching frequency | 0 ... 1 Hz | |
Current consumption | ||
Measuring plate not detected | max. 1 mA | |
Measuring plate detected | &ge 2.4 mA | |
Compliance with standards and directives | ||
Standard conformity | ||
NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
Approvals and certificates | ||
FM approval | ||
Control drawing | 116-0165 | |
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Mechanical specifications | ||
Connection type | cable PVC , 2 m | |
Core cross-section | 0.75 mm2 | |
Housing material | PBT | |
Sensing face | PBT | |
Degree of protection | IP68 | |
Cable | ||
Bending radius | > 10 x cable diameter | |
General information | ||
Use in the hazardous area | see instruction manuals | |
Category | 1G 2G 1D |
General specifications | ||
---|---|---|
Switching function | Normally open (NO) | |
Output type | PNP | |
Output polarity | DC | |
Output type | 3-wire | |
Nominal ratings | ||
Operating voltage | 18 ... 30 V | |
Reverse polarity protection | reverse polarity protected | |
Short-circuit protection | short-circuit protected | |
Operating current | 0 ... 200 mA | |
No-load supply current | &le 20 mA | |
Approvals and certificates | ||
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -35 ... 50 °C (-31 ... 122 °F) | |
Mechanical specifications | ||
Connection type | cable PVC , 300 mm | |
Core cross-section | 0.34 mm2 | |
Housing material | POM | |
Sensing face | POM | |
Degree of protection | IP67 |
Описание оборудования | ||
---|---|---|
Palm Button |
Описание оборудования | ||
---|---|---|
Palm Button |
Описание оборудования | ||
---|---|---|
Palm Button |
General specifications | ||
---|---|---|
Output type | Analog current output or analog voltage output | |
Installation | non-flush | |
Output polarity | DC | |
Measurement range | 2 ... 8 mm | |
Output type | 3-wire | |
Nominal ratings | ||
Operating voltage | 18 ... 30 V | |
Output signal | 0 ... 20 mA 0 ... 10 V | |
Reverse polarity protection | reverse polarity protected | |
Linearity error | ± 0.5 % | |
Temperature drift | &le 0.2 % / K v.E. | |
Repeat accuracy | < 0.02 mm | |
No-load supply current | &le 15 mA | |
Load resistor | voltage output: &ge 4,7 k&Omega current output: &le 200 &Omega | |
Approvals and certificates | ||
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Mechanical specifications | ||
Connection type | M12 x 1 | |
Housing material | brass, nickel-plated | |
Sensing face | PBT | |
Degree of protection | IP67 |
General specifications | ||
---|---|---|
Output type | Analog voltage output | |
Installation | quasi flush | |
Output polarity | DC | |
Measurement range | 0 ... 6 mm | |
Nominal ratings | ||
Operating voltage | 10 ... 30 V | |
Limit frequency (3dB) | 1000 Hz at s = 3 mm | |
Reverse polarity protection | yes | |
Short-circuit protection | yes | |
Repeat accuracy | 0 ... 1 µm | |
No-load supply current | &le 10 mA | |
Analog output | ||
Output type | 0 ... 5 V | |
Load resistor | &ge 500 &Omega | |
Temperature drift | ± 5 % (0 ... 70 °C) ± 10 % (-25 ... 0 °C) | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Mechanical specifications | ||
Connection type | Connector M12 x 1 , 4-pin | |
Housing material | chromium plated brass | |
Sensing face | PBT | |
Housing diameter | 12 mm | |
Degree of protection | IP67 |
General specifications | ||
---|---|---|
Output type | Analog current output or analog voltage output | |
Installation | quasi flush | |
Output polarity | DC | |
Measurement range | 0 ... 6 mm | |
Output type | 4-wire | |
Nominal ratings | ||
Operating voltage | 15 ... 30 V , residual ripple 20 % UB | |
Limit frequency (3dB) | 1000 Hz | |
Reverse polarity protection | yes | |
Short-circuit protection | yes | |
Repeat accuracy | 0 ... 10 µm | |
No-load supply current | &le 10 mA | |
Functional safety related parameters | ||
MTTFd | 464 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Analog output | ||
Output type | 0 ... 10 V / 4 ... 20 mA | |
Load resistor | voltage output: &ge 500 &Omega current output: &le 500 &Omega | |
Temperature drift | ± 5 % (0 ... 70 °C) ± 10 % (-25 ... 0 °C) | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Mechanical specifications | ||
Connection type | Connector M12 x 1 , 4-pin | |
Housing material | chromium plated brass | |
Sensing face | PBT | |
Housing diameter | 12 mm | |
Degree of protection | IP67 |
General specifications | ||
---|---|---|
Output type | Analog current output | |
Installation | flush | |
Output polarity | DC | |
Measurement range | 1 ... 5 mm | |
Output type | 3-wire | |
Nominal ratings | ||
Operating voltage | 10 ... 30 V | |
Repeat accuracy | 0 ... 20 µm | |
No-load supply current | &le 12 mA | |
Functional safety related parameters | ||
MTTFd | 718 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Analog output | ||
Output type | 4 ... 20 mA | |
Linearity error | &le ± 4 % of full-scale value | |
Load resistor | &le 1000 &Omega | |
Temperature drift | &le ± 0.1 %/K of the measured value | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Mechanical specifications | ||
Connection type | cable PVC , 2 m | |
Core cross-section | 0.5 mm2 | |
Housing material | brass, nickel-plated | |
Sensing face | PBT | |
Degree of protection | IP67 |
General specifications | ||
---|---|---|
Output type | Analog current output | |
Installation | flush | |
Output polarity | DC | |
Measurement range | 1 ... 5 mm | |
Output type | 3-wire | |
Nominal ratings | ||
Operating voltage | 10 ... 30 V | |
Repeat accuracy | 0 ... 20 µm | |
No-load supply current | &le 12 mA | |
Functional safety related parameters | ||
MTTFd | 718 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Analog output | ||
Output type | 4 ... 20 mA | |
Linearity error | &le ± 4 % of full-scale value | |
Load resistor | &le 1000 &Omega | |
Temperature drift | &le ± 0.1 %/K of the measured value | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Mechanical specifications | ||
Connection type | Connector M12 x 1 , 4-pin | |
Housing material | brass, nickel-plated | |
Sensing face | PBT | |
Degree of protection | IP67 |
General specifications | ||
---|---|---|
Output type | Analog current output | |
Installation | flush | |
Output polarity | DC | |
Measurement range | 1 ... 5 mm | |
Output type | 3-wire | |
Nominal ratings | ||
Operating voltage | 10 ... 30 V | |
Repeat accuracy | 0 ... 20 µm | |
No-load supply current | &le 12 mA | |
Analog output | ||
Output type | 0 ... 20 mA | |
Linearity error | &le ± 4 % of full-scale value | |
Load resistor | &le 1000 &Omega | |
Temperature drift | &le ± 0.1 %/K of the measured value | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Mechanical specifications | ||
Connection type | cable PVC , 2 m | |
Core cross-section | 0.5 mm2 | |
Housing material | brass, nickel-plated | |
Sensing face | PBT | |
Degree of protection | IP67 |
General specifications | ||
---|---|---|
Output type | Analog current output | |
Installation | flush | |
Output polarity | DC | |
Measurement range | 1 ... 5 mm | |
Output type | 3-wire | |
Nominal ratings | ||
Operating voltage | 10 ... 30 V | |
Repeat accuracy | 0 ... 20 µm | |
No-load supply current | &le 12 mA | |
Analog output | ||
Output type | 0 ... 20 mA | |
Linearity error | &le ± 4 % of full-scale value | |
Load resistor | &le 1000 &Omega | |
Temperature drift | &le ± 0.1 %/K of the measured value | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Mechanical specifications | ||
Connection type | Connector M12 x 1 , 4-pin | |
Housing material | brass, nickel-plated | |
Sensing face | PBT | |
Degree of protection | IP67 |
General specifications | ||
---|---|---|
Output type | Analog current output | |
Installation | flush | |
Output polarity | DC | |
Measurement range | 3 ... 8 mm | |
Output type | 3-wire | |
Nominal ratings | ||
Operating voltage | 15 ... 30 V DC | |
Repeat accuracy | 0 ... 200 µm | |
Recovery time | 1 ... 10 ms typ. 5 ms | |
No-load supply current | &le 12 mA | |
Analog output | ||
Output type | 0 ... 20 mA | |
Linearity error | &le ± 5 % of full-scale value | |
Load resistor | &le 500 &Omega | |
Temperature drift | &le ± 0.15 %/K of the measured value | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Mechanical specifications | ||
Connection type | cable PVC , 2 m | |
Core cross-section | 0.75 mm2 | |
Housing material | brass, nickel-plated | |
Sensing face | PBT | |
Degree of protection | IP67 |
General specifications | ||
---|---|---|
Output type | Analog current output | |
Installation | non-flush | |
Output polarity | DC | |
Measurement range | 5 ... 15 mm | |
Output type | 3-wire | |
Nominal ratings | ||
Operating voltage | 15 ... 30 V DC | |
Repeat accuracy | 0 ... 200 µm | |
No-load supply current | &le 12 mA | |
Analog output | ||
Output type | 0 ... 20 mA | |
Linearity error | &le ± 5 % of full-scale value | |
Load resistor | &le 500 &Omega | |
Temperature drift | &le ± 0.15 %/K of the measured value | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Mechanical specifications | ||
Connection type | cable PVC , 2 m | |
Core cross-section | 0.75 mm2 | |
Housing material | Stainless steel V2A | |
Sensing face | PBT | |
Degree of protection | IP67 |
General specifications | ||
---|---|---|
Output type | Analog current output | |
Installation | non-flush | |
Output polarity | DC | |
Measurement range | 5 ... 15 mm | |
Output type | 3-wire | |
Nominal ratings | ||
Operating voltage | 15 ... 30 V DC | |
Repeat accuracy | 0 ... 200 µm | |
No-load supply current | &le 12 mA | |
Analog output | ||
Output type | 0 ... 20 mA | |
Linearity error | &le ± 5 % of full-scale value | |
Load resistor | &le 500 &Omega | |
Temperature drift | &le ± 0.15 %/K of the measured value | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Mechanical specifications | ||
Connection type | cable PVC , 5 m | |
Core cross-section | 0.75 mm2 | |
Housing material | Stainless steel V2A | |
Sensing face | PBT | |
Degree of protection | IP67 |
Описание оборудования | ||
---|---|---|
  |
Описание оборудования | ||
---|---|---|
  |
Описание оборудования | ||
---|---|---|
  |
Описание оборудования | ||
---|---|---|
  |
General specifications | ||
---|---|---|
Switching function | 2 x normally open (NO) | |
Output type | PNP | |
Rated operating distance | 2 mm | |
Installation | non-flush | |
Output polarity | DC | |
Assured operating distance | 0 ... 1.62 mm | |
Reduction factor rAl | 0.45 | |
Reduction factor rCu | 0.35 | |
Reduction factor r304 | 0.75 | |
Nominal ratings | ||
Operating voltage | 10 ... 30 V | |
Switching frequency | 0 ... 100 Hz | |
Reverse polarity protection | reverse polarity protected | |
Short-circuit protection | pulsing | |
Voltage drop | &le 3 V | |
Operating current | 0 ... 100 mA | |
No-load supply current | &le 15 mA | |
Constant magnetic field | 100 mT | |
Alternating magnetic field | 100 mT | |
Tuning-out | typically 1 s | |
Operating voltage indicator | LED green | |
Switching state indicator | Switching state "closed" = LED red (S2) switching state "open" = LED yellow (S1) | |
Functional safety related parameters | ||
MTTFd | 1445 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | 0 ... 50 °C (32 ... 122 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Connection type | Connector M12 x 1 , 4-pin | |
Flexible lead, housing-sensor | 80 mm , PUR (halogen-free) Outlet position - 1 | |
Housing material | amplifier PBT, PA6 + GD-ZN AL4 oscillators PBT | |
Degree of protection | IP65 |
General specifications | ||
---|---|---|
Switching function | 2 x normally open (NO) | |
Output type | PNP | |
Rated operating distance | 2 mm | |
Installation | non-flush | |
Output polarity | DC | |
Assured operating distance | 0 ... 1.62 mm | |
Reduction factor rAl | 0.45 | |
Reduction factor rCu | 0.35 | |
Reduction factor r304 | 0.75 | |
Nominal ratings | ||
Operating voltage | 10 ... 30 V | |
Switching frequency | 0 ... 100 Hz | |
Reverse polarity protection | reverse polarity protected | |
Short-circuit protection | pulsing | |
Voltage drop | &le 3 V | |
Operating current | 0 ... 100 mA | |
No-load supply current | &le 15 mA | |
Constant magnetic field | 100 mT | |
Alternating magnetic field | 100 mT | |
Operating voltage indicator | LED green | |
Switching state indicator | Switching state "close" = LED white switching state "open" = LED yellow | |
Functional safety related parameters | ||
MTTFd | 1445 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | 0 ... 50 °C (32 ... 122 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Connection type | Connector M12 x 1 , 4-pin | |
Flexible lead, housing-sensor | PUR (halogen-free) Outlet position - 3 | |
Housing material | amplifier PBT, PA6 + GD-ZN AL4 oscillators PBT | |
Sensing face | PBT | |
Degree of protection | IP65 |
General specifications | ||
---|---|---|
Switching function | 2 x normally open (NO) | |
Output type | PNP | |
Rated operating distance | 2 mm | |
Installation | non-flush | |
Output polarity | DC | |
Assured operating distance | 0 ... 1.62 mm | |
Reduction factor rAl | 0.45 | |
Reduction factor rCu | 0.35 | |
Reduction factor r304 | 0.75 | |
Output type | 4-wire | |
Nominal ratings | ||
Operating voltage | 10 ... 30 V | |
Switching frequency | 0 ... 100 Hz | |
Reverse polarity protection | reverse polarity protected | |
Short-circuit protection | pulsing | |
Voltage drop | &le 3 V | |
Operating current | 0 ... 100 mA | |
No-load supply current | &le 15 mA | |
Constant magnetic field | 100 mT | |
Alternating magnetic field | 100 mT | |
Operating voltage indicator | LED green | |
Switching state indicator | Switching state "close" = LED white switching state "open" = LED yellow | |
Functional safety related parameters | ||
MTTFd | 1445 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Approvals and certificates | ||
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | 0 ... 50 °C (32 ... 122 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Connection type | Connector M12 x 1 , 4-pin | |
Flexible lead, housing-sensor | 60 mm PUR (halogen-free) Outlet position - 3 | |
Housing material | amplifier PBT, PA6 + GD-ZN AL4 oscillators PBT | |
Sensing face | PBT | |
Degree of protection | IP65 |
General specifications | ||
---|---|---|
Switching function | 2 x normally open (NO) | |
Output type | PNP | |
Rated operating distance | 2 mm | |
Installation | non-flush | |
Output polarity | DC | |
Assured operating distance | 0 ... 1.62 mm | |
Reduction factor rAl | 0.45 | |
Reduction factor rCu | 0.35 | |
Reduction factor r304 | 0.75 | |
Nominal ratings | ||
Operating voltage | 10 ... 30 V | |
Switching frequency | 0 ... 100 Hz | |
Reverse polarity protection | reverse polarity protected | |
Short-circuit protection | pulsing | |
Voltage drop | &le 3 V | |
Operating current | 0 ... 100 mA | |
No-load supply current | &le 15 mA | |
Constant magnetic field | 100 mT | |
Alternating magnetic field | 100 mT | |
Operating voltage indicator | LED green | |
Switching state indicator | Switching state "closed" = LED red (S2) switching state "open" = LED yellow (S1) | |
Functional safety related parameters | ||
MTTFd | 1402 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Ambient conditions | ||
Ambient temperature | 0 ... 50 °C (32 ... 122 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Connection type | Connector M12 x 1 , 4-pin | |
Flexible lead, housing-sensor | 100 mm , PUR (halogen-free) | |
Housing material | Amplifier: PA66 Badamid, Oscillators: PBT | |
Degree of protection | IP65 |