Атол 30Ф не включается (заводской брак)
Валерий
14 января 2022
Mechanical specifications | ||
---|---|---|
Degree of protection | IP65 | |
Material | ||
Enclosure | Aluminum alloy | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) (+40 °C (104 °F)) | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | INERIS 05 ATEX 0030 | |
Group, category, type of protection, temperature class | ![]() | |
General information | ||
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
Mechanical specifications | ||
---|---|---|
Degree of protection | IP65 | |
Material | ||
Enclosure | Aluminum alloy | |
Glass | Tempered glass | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) (+40 °C (104 °F)) | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | INERIS 05 ATEX 0030 | |
Group, category, type of protection, temperature class | ![]() | |
General information | ||
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
Electrical specifications | ||
---|---|---|
Operating voltage | 420 V max. | |
Operating current | 20 A | |
Terminal capacity | 2.5 mm2 | |
Function | double pushbutton : 1 x pushbutton , green 1 x mushroom button , latching | |
Contact configuration | 1 N/O & 1 N/C ( each button ) | |
Operator action | momentary latching , pull to release | |
Labeling | Start - Stop | |
Mechanical specifications | ||
Height | 110 mm | |
Width | 110 mm | |
Depth | 122 mm | |
Cover fixing | M6 stainless steel socket cap head screws | |
Degree of protection | IP66 | |
Cable entry | metric threaded | |
Number of cable entries | 1 x M20 in face A fitted with nylon Ex e sealing plug 1 x M20 in face B fitted with nylon Ex e cable gland N.B. nylon plugs and glands limit lower ambient temperature to -20°C. -40°C when used with a plug and gland rated to -40°C | |
Material | ||
Enclosure | carbon loaded, anti static glass fiber reinforced polyester (GRP) | |
Finish | inherent color black | |
Seal | one piece solid silicone rubber | |
Mass | approx. 0.7 kg | |
Mounting | 7 mm slots moulded into base | |
Grounding | internal brass grounding terminal on base | |
Ambient conditions | ||
Ambient temperature | -40 ... 55 °C (-40 ... 131 °F) | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | SIRA 03 ATEX 3293 | |
Group, category, type of protection, temperature class | ![]() Ex ed IIC T6 Gb, Ex tb IIIC T85°C Db | |
International approvals | ||
IECEx approval | IECEx SIR 10.0078 | |
GOST-R approval | GOST-R B01008 | |
Conformity | ||
Degree of protection | EN 60529 | |
General information | ||
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
Mechanical specifications | ||
---|---|---|
Degree of protection | IP65 (IP67 with O-ring) | |
Material | ||
Enclosure | Aluminum alloy | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) (+40 °C (104 °F)) | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | INERIS 05 ATEX 0030 | |
Group, category, type of protection, temperature class | ![]() | |
General information | ||
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
Mechanical specifications | ||
---|---|---|
Degree of protection | IP65 (IP67 with O-ring) | |
Material | ||
Enclosure | Aluminum alloy | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) (+40 °C (104 °F)) | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | INERIS 05 ATEX 0030 | |
Group, category, type of protection, temperature class | ![]() | |
General information | ||
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
Functional safety related parameters | ||
---|---|---|
Safety Integrity Level (SIL) | SIL 3 | |
Supply | ||
Connection | SL1: 1a, 1b(-) 2a, 2b(+) | |
Rated voltage | 20.4 ... 30 V DC via Termination Board | |
Rated current | 28 mA at 24 V , RS-485, quiescent current | |
Power dissipation | 0.7 W at 24 V | |
HART signal channels (non-intrinsically safe) | ||
Number of channels | 32 | |
Conformity | HART field device input (revision 5 to 7) | |
Signal range | 0.12 Vpp < signal < 1.5 Vpp | |
Leakage current | < 3 µA at -20 ... 85 °C (-4 ... 185 °F) | |
Terminating resistor | external 230 ... 500 &Omega standard (up to 1000 &Omega possible) | |
Output voltage | &ge 400 mV ss (with the terminator resistance specified above) | |
Output resistance | 100 &Omega or smaller, capacitive coupling | |
DC isolation | dual capacitor each channel | |
Common mode voltage | up to 30 V | |
Input impedance | > 5 k&Omega , according to HART specification | |
Input voltage range | 0.12 ... 1.5 V ss | |
Common mode voltage | max. 30 V | |
Differential mode clamping | ± 5.2 V , for transient or AC signals | |
Common mode clamping | ± 10 V , for transient or AC signals | |
Carrier detect level | signal > 0.12 Vpp, carrier detection activated signal < 0.08 Vpp, carrier detection not activated | |
Transmit amplitude | 200 &Omega load, 0.43 Vpp < signal < 0.49 Vpp 500 &Omega load, 1.1 Vpp < signal < 1.2 Vpp | |
Device type | DC isolated bus device | |
Impedance | high impedance | |
Data link type | HART primary and secondary | |
Field multi point support | option available upon request | |
Interface | ||
Transfer rate | 9600 MBit/s, 19200 MBit/s or 38400 MBit/s, selectable via switch | |
Address | 1 ... 31 , adjustable via DIP switch | |
Type | RS-485 , differential pair and grounding | |
Topology | multi point, master/slave connection | |
Indicators/settings | ||
Display elements | LEDs LED PWR ON (power supply), one green LED LED HART TX (HART transmission), one yellow LED LED FAULT (lead fault), one red LED | |
Control elements | DIP switches at the housing side for: - unit slave address - baud rate - test mode on/off | |
Configuration | via DIP switches | |
Labeling | space for labeling at the front | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Conformity | ||
Electromagnetic compatibility | NE 21:2012 For further information see system description. | |
Degree of protection | IEC 60529:2001 | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Mass | approx. 140 g | |
Dimensions | 18 x 106 x 128 mm (0.7 x 4.2 x 5 inch) | |
Mounting | on Termination Board | |
Data for application in connection with hazardous areas | ||
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-15:2010 | |
International approvals | ||
CSA approval | 1256050 | |
Approved for | Class I, Division 2, Groups A, B, C, D Class I, Zone 2, IIC |
Functional safety related parameters | ||
---|---|---|
Safety Integrity Level (SIL) | SIL 3 | |
Supply | ||
Connection | terminals 17+, 18- | |
Rated voltage | 20 ... 32 V DC typical at 100 mA | |
Power consumption | max. 3 W | |
HART signal channels (non-intrinsically safe) | ||
Conformity | HART field device input (revision 5 to 7) | |
Connection | 26-pin flat cable for analog connections 14-pin flat cable for master-slave connection between KFD2-HMM-16 and KFD0-HMS-16 | |
Leakage current | < 3 µA at -20 ... 85 °C (-4 ... 185 °F) | |
Terminating resistor | external 230 ... 500 &Omega standard (up to 1000 &Omega possible) | |
Output voltage | &ge 400 mV ss (with the terminator resistance specified above) | |
Output resistance | 100 &Omega or smaller, capacitive coupling | |
Input impedance | according to HART specification | |
Input voltage range | 0.08 ... 4 V ss typ. ± 5.2 V as local reference | |
Interface | ||
Transfer rate | 9600, 19200, or 38400 Bit/s (selectable with DIL switch (2 and 3) by the user) | |
Type | RS-485 , 2-wire multidrop | |
Address selection | One of 31 possible addresses selectable per DIL switch (4 ... 8) | |
Indicators/settings | ||
Control elements | DIP-switch | |
Configuration | via DIP switches | |
Labeling | space for labeling at the front | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Conformity | ||
Degree of protection | IEC 60529:2001 | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Mass | approx. 250 g | |
Dimensions | 40 x 107 x 115 mm (1.6 x 4.2 x 4.5 inch) , housing type C1 | |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
Data for application in connection with hazardous areas | ||
Certificate | PF 07 CERT 1143 X | |
Marking | ![]() | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-15:2010 |
Functional safety related parameters | ||
---|---|---|
Safety Integrity Level (SIL) | SIL 3 | |
Supply | ||
Connection | via 14-channel flat cable form master KFD2-HMM-16 | |
HART signal channels (non-intrinsically safe) | ||
Conformity | HART field device input (revision 5 to 7) | |
Connection | 26-pin flat cable for analog connections 14-pin flat cable for master-slave connection between KFD2-HMM-16 and KFD0-HMS-16 | |
Leakage current | < 3 µA at -20 ... 85 °C (-4 ... 185 °F) | |
Terminating resistor | external 230 ... 500 &Omega standard (up to 1000 &Omega possible) | |
Output voltage | &ge 400 mV ss (with the terminator resistance specified above) | |
Output resistance | 100 &Omega or smaller, capacitive coupling | |
Input impedance | according to HART specification | |
Input voltage range | 0.08 ... 4 V ss typ. ± 5.2 V as local reference | |
Indicators/settings | ||
Labeling | space for labeling at the front | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Conformity | ||
Degree of protection | IEC 60529:2001 | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Mass | approx. 100 g | |
Dimensions | 20 x 93 x 115 mm (0.8 x 3.7 x 4.5 inch) , housing type B1 | |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
Data for application in connection with hazardous areas | ||
Certificate | PF 07 CERT 1143 X | |
Marking | ![]() | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-15:2010 |
General specifications | ||
---|---|---|
Suitable components | backplane LB9025A , LB8105* , LB8106* , LB8108* , LB8109* , LB8107* | |
Slots | ||
Bus coupler | 1 | |
Supply | 1 | |
I/O modules (single width) | max. 8 | |
I/O modules (dual width) | max. 4 | |
Supply | ||
Maximum safe voltage | 60 V DC (SELV/PELV) | |
Input voltage range | 18 ... 32 V DC (SELV/PELV) | |
Fieldbus interface | ||
Fieldbus type | PROFIBUS DP/DP-V1 or MODBUS RTU , depends on bus coupler | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2006 | |
Conformity | ||
Electromagnetic compatibility | NE 21 | |
Degree of protection | EN 60529 | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) , 70 °C (non-Ex) | |
Storage temperature | -25 ... 85 °C (-13 ... 185 °F) | |
Shock resistance | shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18 | |
Vibration resistance | frequency range 10 ... 150 Hz transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g 10 cycles frequency range 5 ... 100 Hz transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g 90 minutes at each resonance | |
Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Mass | approx. 1010 g | |
Dimensions | (W x H x D) 275 x 127 x 80 mm (10.8 x 5 x 3.15 inch) , without modules | |
Data for application in connection with hazardous areas | ||
Certificate | PF 08 CERT 1234 X | |
Marking | ![]() | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2009 EN 60079-15:2010 | |
International approvals | ||
ATEX approval | PF 08 CERT 1234 X | |
UL approval | E106378 | |
Control drawing | 116-0321 | |
Approved for | cUL (Canada): CL I Zn. 2 IIC IS circuits for CL I Zn. 0 IIC ULus (USA): CL I Div. 2 Grp. A, B, C, D IS circuits for CL I, II, III Div. 1 Grp. A, B, C, D, E, F, G | |
IECEx approval | BVS 09.0037X | |
Approved for | Ex nA IIC T4 Gc | |
EAC approval | Russia: RU C-IT.MIII06.B.00129 | |
Marine approval | ||
Lloyd Register | 15/20021 | |
DNV GL Marine | TAA0000034 | |
American Bureau of Shipping | T1450280/UN | |
Bureau Veritas Marine | 22449/B0 BV |
General specifications | ||
---|---|---|
Suitable components | backplane LB9025A , LB8111A2* | |
Slots | ||
Bus coupler | 1 | |
Supply | 1 | |
I/O modules (single width) | max. 8 | |
I/O modules (dual width) | max. 4 | |
Supply | ||
Maximum safe voltage | 60 V DC (SELV/PELV) | |
Input voltage range | 18 ... 32 V DC (SELV/PELV) | |
Fieldbus interface | ||
Fieldbus type | MODBUS TCP | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2006 | |
Conformity | ||
Electromagnetic compatibility | NE 21 | |
Degree of protection | EN 60529 | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) , 70 °C (non-Ex) | |
Storage temperature | -25 ... 85 °C (-13 ... 185 °F) | |
Shock resistance | shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18 | |
Vibration resistance | frequency range 10 ... 150 Hz transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g 10 cycles frequency range 5 ... 100 Hz transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g 90 minutes at each resonance | |
Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Mass | approx. 1010 g | |
Dimensions | (W x H x D) 275 x 127 x 80 mm (10.8 x 5 x 3.15 inch) , without modules | |
Data for application in connection with hazardous areas | ||
Certificate | PF 08 CERT 1234 X | |
Marking | ![]() | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2009 EN 60079-15:2010 | |
International approvals | ||
ATEX approval | PF 08 CERT 1234 X | |
UL approval | E106378 | |
Control drawing | 116-0321 | |
Approved for | cUL (Canada): CL I Zn. 2 IIC IS circuits for CL I Zn. 0 IIC ULus (USA): CL I Div. 2 Grp. A, B, C, D IS circuits for CL I, II, III Div. 1 Grp. A, B, C, D, E, F, G | |
IECEx approval | BVS 09.0037X | |
Approved for | Ex nA IIC T4 Gc | |
EAC approval | Russia: RU C-IT.MIII06.B.00129 | |
Marine approval | ||
Lloyd Register | 15/20021 | |
American Bureau of Shipping | T1450280/UN | |
Bureau Veritas Marine | 22449/B0 BV |
General specifications | ||
---|---|---|
Suitable components | backplane LB9027A , LB8105* , LB8106* , LB8108* , LB8109* , LB8107* | |
Slots | ||
Bus coupler | 1 | |
Supply | 2 | |
I/O modules (single width) | max. 16 | |
I/O modules (dual width) | max. 8 | |
Supply | ||
Maximum safe voltage | 60 V DC (SELV/PELV) | |
Input voltage range | 18 ... 32 V DC (SELV/PELV) | |
Fieldbus interface | ||
Fieldbus type | PROFIBUS DP/DP-V1 or MODBUS RTU , depends on bus coupler | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2006 | |
Conformity | ||
Electromagnetic compatibility | NE 21 | |
Degree of protection | EN 60529 | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) , 70 °C (non-Ex) | |
Storage temperature | -25 ... 85 °C (-13 ... 185 °F) | |
Shock resistance | shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18 | |
Vibration resistance | frequency range 10 ... 150 Hz transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g 10 cycles frequency range 5 ... 100 Hz transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g 90 minutes at each resonance | |
Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Mass | approx. 1370 g | |
Dimensions | (W x H x D) 440 x 127 x 80 mm (17.3 x 5 x 3.15 inch) , without modules | |
Data for application in connection with hazardous areas | ||
Certificate | PF 08 CERT 1234 X | |
Marking | ![]() | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2009 EN 60079-15:2010 | |
International approvals | ||
ATEX approval | PF 08 CERT 1234 X | |
UL approval | E106378 | |
Control drawing | 116-0321 | |
Approved for | cUL (Canada): CL I Zn. 2 IIC IS circuits for CL I Zn. 0 IIC ULus (USA): CL I Div. 2 Grp. A, B, C, D IS circuits for CL I, II, III Div. 1 Grp. A, B, C, D, E, F, G | |
IECEx approval | BVS 09.0037X | |
Approved for | Ex nA IIC T4 Gc | |
EAC approval | Russia: RU C-IT.MIII06.B.00129 | |
Marine approval | ||
Lloyd Register | 15/20021 | |
DNV GL Marine | TAA0000034 | |
American Bureau of Shipping | T1450280/UN | |
Bureau Veritas Marine | 22449/B0 BV |
General specifications | ||
---|---|---|
Suitable components | backplane LB9027A , LB8111A2* | |
Slots | ||
Bus coupler | 1 | |
Supply | 2 | |
I/O modules (single width) | max. 16 | |
I/O modules (dual width) | max. 8 | |
Supply | ||
Maximum safe voltage | 60 V DC (SELV/PELV) | |
Input voltage range | 18 ... 32 V DC (SELV/PELV) | |
Fieldbus interface | ||
Fieldbus type | MODBUS TCP | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2006 | |
Conformity | ||
Electromagnetic compatibility | NE 21 | |
Degree of protection | EN 60529 | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) , 70 °C (non-Ex) | |
Storage temperature | -25 ... 85 °C (-13 ... 185 °F) | |
Shock resistance | shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18 | |
Vibration resistance | frequency range 10 ... 150 Hz transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g 10 cycles frequency range 5 ... 100 Hz transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g 90 minutes at each resonance | |
Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Mass | approx. 1370 g | |
Dimensions | (W x H x D) 440 x 127 x 80 mm (17.3 x 5 x 3.15 inch) , without modules | |
Data for application in connection with hazardous areas | ||
Certificate | PF 08 CERT 1234 X | |
Marking | ![]() | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2009 EN 60079-15:2010 | |
International approvals | ||
ATEX approval | PF 08 CERT 1234 X | |
UL approval | E106378 | |
Control drawing | 116-0321 | |
Approved for | cUL (Canada): CL I Zn. 2 IIC IS circuits for CL I Zn. 0 IIC ULus (USA): CL I Div. 2 Grp. A, B, C, D IS circuits for CL I, II, III Div. 1 Grp. A, B, C, D, E, F, G | |
IECEx approval | BVS 09.0037X | |
Approved for | Ex nA IIC T4 Gc | |
EAC approval | Russia: RU C-IT.MIII06.B.00129 | |
Marine approval | ||
Lloyd Register | 15/20021 | |
American Bureau of Shipping | T1450280/UN | |
Bureau Veritas Marine | 22449/B0 BV |
General specifications | ||
---|---|---|
Suitable components | backplane LB9022E , backplane LB9022S , LB8111A2* , LB8105* , LB8106* , LB8108* , LB8109* , LB8107* | |
Slots | ||
Supply | 3 | |
Output shut-down | 5 SIL2 output shutdown segments slots 25 ... 29, 30 ... 34, 35 ... 39, 40 ... 44, 45 ... 48 | |
I/O modules (single width) | max. 24 | |
I/O modules (dual width) | max. 12 | |
Supply | ||
Maximum safe voltage | 60 V DC (SELV/PELV) | |
Input voltage range | 18 ... 32 V DC (SELV/PELV) | |
Fieldbus interface | ||
Fieldbus type | PROFIBUS DP/DP-V1, MODBUS RTU, or MODBUS TCP , depending on the base backplane | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2006 | |
Conformity | ||
Electromagnetic compatibility | NE 21 | |
Degree of protection | EN 60529 | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) , 70 °C (non-Ex) | |
Storage temperature | -25 ... 85 °C (-13 ... 185 °F) | |
Shock resistance | shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18 | |
Vibration resistance | frequency range 10 ... 150 Hz transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g 10 cycles frequency range 5 ... 100 Hz transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g 90 minutes at each resonance | |
Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Mass | approx. 1800 g | |
Dimensions | (W x H x D) 605 x 127 x 80 mm (23.8 x 5 x 3.15 inch) , without modules | |
Data for application in connection with hazardous areas | ||
Certificate | PF 08 CERT 1234 X | |
Marking | ![]() | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2009 EN 60079-15:2010 | |
International approvals | ||
ATEX approval | PF 08 CERT 1234 X | |
UL approval | E106378 | |
Control drawing | 116-0321 | |
Approved for | cUL (Canada): CL I Zn. 2 IIC IS circuits for CL I Zn. 0 IIC ULus (USA): CL I Div. 2 Grp. A, B, C, D IS circuits for CL I, II, III Div. 1 Grp. A, B, C, D, E, F, G | |
IECEx approval | BVS 09.0037X | |
Approved for | Ex nA IIC T4 Gc | |
EAC approval | Russia: RU C-IT.MIII06.B.00129 | |
Marine approval | ||
Lloyd Register | 15/20021 | |
American Bureau of Shipping | T1450280/UN | |
Bureau Veritas Marine | 22449/B0 BV |
General specifications | ||
---|---|---|
Suitable components | backplane LB9023A , backplane LB9023E , LB8111A2* , LB8105* , LB8106* , LB8108* , LB8109* , LB8107* | |
Slots | ||
Supply | 1 | |
I/O modules (single width) | max. 8 | |
I/O modules (dual width) | max. 4 | |
Supply | ||
Maximum safe voltage | 60 V DC (SELV/PELV) | |
Input voltage range | 18 ... 32 V DC (SELV/PELV) | |
Fieldbus interface | ||
Fieldbus type | PROFIBUS DP/DP-V1 or MODBUS RTU , depending on the base backplane | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2006 | |
Conformity | ||
Electromagnetic compatibility | NE 21 | |
Degree of protection | EN 60529 | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) , 70 °C (non-Ex) | |
Storage temperature | -25 ... 85 °C (-13 ... 185 °F) | |
Shock resistance | shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18 | |
Vibration resistance | frequency range 10 ... 150 Hz transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g 10 cycles frequency range 5 ... 100 Hz transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g 90 minutes at each resonance | |
Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Mass | approx. 980 g | |
Dimensions | (W x H x D) 275 x 127 x 80 mm (10.8 x 5 x 3.15 inch) , without modules | |
Data for application in connection with hazardous areas | ||
Certificate | PF 08 CERT 1234 X | |
Marking | ![]() | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2009 EN 60079-15:2010 | |
International approvals | ||
ATEX approval | PF 08 CERT 1234 X | |
UL approval | E106378 | |
Control drawing | 116-0321 | |
Approved for | cUL (Canada): CL I Zn. 2 IIC IS circuits for CL I Zn. 0 IIC ULus (USA): CL I Div. 2 Grp. A, B, C, D IS circuits for CL I, II, III Div. 1 Grp. A, B, C, D, E, F, G | |
IECEx approval | BVS 09.0037X | |
Approved for | Ex nA IIC T4 Gc | |
EAC approval | Russia: RU C-IT.MIII06.B.00129 | |
Marine approval | ||
Lloyd Register | 15/20021 | |
DNV GL Marine | TAA0000034 | |
American Bureau of Shipping | T1450280/UN | |
Bureau Veritas Marine | 22449/B0 BV |
General specifications | ||
---|---|---|
Suitable components | backplane LB9026A , backplane LB9026E , LB8111A2* , LB8105* , LB8106* , LB8108* , LB8109* , LB8107* | |
Slots | ||
Supply | 2 | |
I/O modules (single width) | max. 16 | |
I/O modules (dual width) | max. 8 | |
Supply | ||
Maximum safe voltage | 60 V DC (SELV/PELV) | |
Input voltage range | 18 ... 32 V DC (SELV/PELV) | |
Fieldbus interface | ||
Fieldbus type | PROFIBUS DP/DP-V1, MODBUS RTU, or MODBUS TCP , depending on the base backplane | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2006 | |
Conformity | ||
Electromagnetic compatibility | NE 21 | |
Degree of protection | EN 60529 | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) , 70 °C (non-Ex) | |
Storage temperature | -25 ... 85 °C (-13 ... 185 °F) | |
Shock resistance | shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18 | |
Vibration resistance | frequency range 10 ... 150 Hz transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g 10 cycles frequency range 5 ... 100 Hz transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g 90 minutes at each resonance | |
Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Mass | approx. 1340 g | |
Dimensions | (W x H x D) 440 x 127 x 80 mm (17.3 x 5 x 3.15 inch) , without modules | |
Data for application in connection with hazardous areas | ||
Certificate | PF 08 CERT 1234 X | |
Marking | ![]() | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2009 EN 60079-15:2010 | |
International approvals | ||
ATEX approval | PF 08 CERT 1234 X | |
UL approval | E106378 | |
Control drawing | 116-0321 | |
Approved for | cUL (Canada): CL I Zn. 2 IIC IS circuits for CL I Zn. 0 IIC ULus (USA): CL I Div. 2 Grp. A, B, C, D IS circuits for CL I, II, III Div. 1 Grp. A, B, C, D, E, F, G | |
IECEx approval | BVS 09.0037X | |
Approved for | Ex nA IIC T4 Gc | |
EAC approval | Russia: RU C-IT.MIII06.B.00129 | |
Marine approval | ||
Lloyd Register | 15/20021 | |
DNV GL Marine | TAA0000034 | |
American Bureau of Shipping | T1450280/UN | |
Bureau Veritas Marine | 22449/B0 BV |
General specifications | ||
---|---|---|
Suitable components | LB8110* | |
Slots | ||
Bus coupler | 1 | |
Supply | 1 | |
I/O modules (dual width) | max. 5 | |
Supply | ||
Maximum safe voltage | 60 V DC (SELV/PELV) | |
Input voltage range | 18 ... 32 V DC (SELV/PELV) | |
Fieldbus interface | ||
Fieldbus type | FOUNDATION Fieldbus H1 | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2006 | |
Conformity | ||
Electromagnetic compatibility | NE 21 | |
Degree of protection | EN 60529 | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) , 70 °C (non-Ex) | |
Storage temperature | -25 ... 85 °C (-13 ... 185 °F) | |
Shock resistance | shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18 | |
Vibration resistance | frequency range 10 ... 150 Hz transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g 10 cycles frequency range 5 ... 100 Hz transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g 90 minutes at each resonance | |
Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Mass | approx. 1120 g | |
Dimensions | (W x H x D) 275 x 127 x 80 mm (10.8 x 5 x 3.15 inch) , without modules | |
Data for application in connection with hazardous areas | ||
Certificate | PF 08 CERT 1234 X | |
Marking | ![]() | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2009 EN 60079-15:2010 | |
International approvals | ||
ATEX approval | PF 08 CERT 1234 X | |
UL approval | E106378 | |
Control drawing | 116-0321 | |
Approved for | cUL (Canada): CL I Zn. 2 IIC IS circuits for CL I Zn. 0 IIC ULus (USA): CL I Div. 2 Grp. A, B, C, D IS circuits for CL I, II, III Div. 1 Grp. A, B, C, D, E, F, G | |
IECEx approval | BVS 09.0037X | |
Approved for | Ex nA IIC T4 Gc | |
EAC approval | Russia: RU C-IT.MIII06.B.00129 | |
Marine approval | ||
Lloyd Register | 15/20021 | |
DNV GL Marine | TAA0000034 | |
American Bureau of Shipping | T1450280/UN | |
Bureau Veritas Marine | 22449/B0 BV |
General specifications | ||
---|---|---|
Suitable components | backplane LB9024A , backplane LB9024S , LB8111A2* | |
Slots | ||
Bus coupler | 2 | |
Supply | 3 | |
I/O modules (single width) | max. 22 | |
I/O modules (dual width) | max. 11 | |
Supply | ||
Maximum safe voltage | 60 V DC (SELV/PELV) | |
Input voltage range | 18 ... 32 V DC (SELV/PELV) | |
Fieldbus interface | ||
Fieldbus type | MODBUS TCP | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2006 | |
Conformity | ||
Electromagnetic compatibility | NE 21 | |
Degree of protection | EN 60529 | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) , 70 °C (non-Ex) | |
Storage temperature | -25 ... 85 °C (-13 ... 185 °F) | |
Shock resistance | shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18 | |
Vibration resistance | frequency range 10 ... 150 Hz transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g 10 cycles frequency range 5 ... 100 Hz transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g 90 minutes at each resonance | |
Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Mass | approx. 2170 g | |
Dimensions | (W x H x D) 605 x 127 x 80 mm (23.8 x 5 x 3.15 inch) , without modules | |
Data for application in connection with hazardous areas | ||
Certificate | PF 08 CERT 1234 X | |
Marking | ![]() | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2009 EN 60079-15:2010 | |
International approvals | ||
ATEX approval | PF 08 CERT 1234 X | |
UL approval | E106378 | |
Control drawing | 116-0321 | |
Approved for | cUL (Canada): CL I Zn. 2 IIC IS circuits for CL I Zn. 0 IIC ULus (USA): CL I Div. 2 Grp. A, B, C, D IS circuits for CL I, II, III Div. 1 Grp. A, B, C, D, E, F, G | |
IECEx approval | BVS 09.0037X | |
Approved for | Ex nA IIC T4 Gc | |
EAC approval | Russia: RU C-IT.MIII06.B.00129 | |
Marine approval | ||
Lloyd Register | 15/20021 | |
DNV GL Marine | TAA0000034 | |
American Bureau of Shipping | T1450280/UN | |
Bureau Veritas Marine | 22449/B0 BV |
General specifications | ||
---|---|---|
Suitable components | backplane LB9024S , LB8105* , LB8106* , LB8108* , LB8109* , LB8107* | |
Slots | ||
Bus coupler | 2 | |
Supply | 3 | |
Output shut-down | 5 SIL2 output shutdown segments slots 3 ... 5, 6 ... 10, 11 ... 15, 16 ... 20, 21 ... 24 | |
I/O modules (single width) | max. 22 | |
I/O modules (dual width) | max. 11 | |
Supply | ||
Maximum safe voltage | 60 V DC (SELV/PELV) | |
Input voltage range | 18 ... 32 V DC (SELV/PELV) | |
Fieldbus interface | ||
Fieldbus type | PROFIBUS DP/DP-V1 or MODBUS RTU , depends on bus coupler | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2006 | |
Conformity | ||
Electromagnetic compatibility | NE 21 | |
Degree of protection | EN 60529 | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) , 70 °C (non-Ex) | |
Storage temperature | -25 ... 85 °C (-13 ... 185 °F) | |
Shock resistance | shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18 | |
Vibration resistance | frequency range 10 ... 150 Hz transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g 10 cycles frequency range 5 ... 100 Hz transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g 90 minutes at each resonance | |
Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Mass | approx. 2170 g | |
Dimensions | (W x H x D) 605 x 127 x 80 mm (23.8 x 5 x 3.15 inch) , without modules | |
Data for application in connection with hazardous areas | ||
Certificate | PF 08 CERT 1234 X | |
Marking | ![]() | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2009 EN 60079-15:2010 | |
International approvals | ||
ATEX approval | PF 08 CERT 1234 X | |
UL approval | E106378 | |
Control drawing | 116-0321 | |
Approved for | cUL (Canada): CL I Zn. 2 IIC IS circuits for CL I Zn. 0 IIC ULus (USA): CL I Div. 2 Grp. A, B, C, D IS circuits for CL I, II, III Div. 1 Grp. A, B, C, D, E, F, G | |
IECEx approval | BVS 09.0037X | |
Approved for | Ex nA IIC T4 Gc | |
EAC approval | Russia: RU C-IT.MIII06.B.00129 | |
Marine approval | ||
Lloyd Register | 15/20021 | |
American Bureau of Shipping | T1450280/UN | |
Bureau Veritas Marine | 22449/B0 BV |
General specifications | ||
---|---|---|
Suitable components | backplane LB9024S , LB8105* , LB8106* , LB8108* , LB8109* , LB8107* | |
Slots | ||
Bus coupler | 2 | |
Supply | 3 | |
I/O modules (single width) | max. 12 | |
I/O modules (dual width) | max. 6 | |
Supply | ||
Maximum safe voltage | 60 V DC (SELV/PELV) | |
Input voltage range | 18 ... 32 V DC (SELV/PELV) | |
Fieldbus interface | ||
Fieldbus type | PROFIBUS DP/DP-V1 or MODBUS RTU , depends on bus coupler | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2006 | |
Conformity | ||
Electromagnetic compatibility | NE 21 | |
Degree of protection | EN 60529 | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) , 70 °C (non-Ex) | |
Storage temperature | -25 ... 85 °C (-13 ... 185 °F) | |
Shock resistance | shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18 | |
Vibration resistance | frequency range 10 ... 150 Hz transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g 10 cycles frequency range 5 ... 100 Hz transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g 90 minutes at each resonance | |
Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Mass | approx. 1380 g | |
Dimensions | (W x H x D) 440 x 127 x 80 mm (17.3 x 5 x 3.15 inch) , without modules | |
Data for application in connection with hazardous areas | ||
Certificate | PF 08 CERT 1234 X | |
Marking | ![]() | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2009 EN 60079-15:2010 | |
International approvals | ||
ATEX approval | PF 08 CERT 1234 X | |
UL approval | E106378 | |
Control drawing | 116-0321 | |
Approved for | cUL (Canada): CL I Zn. 2 IIC IS circuits for CL I Zn. 0 IIC ULus (USA): CL I Div. 2 Grp. A, B, C, D IS circuits for CL I, II, III Div. 1 Grp. A, B, C, D, E, F, G | |
IECEx approval | BVS 09.0037X | |
Approved for | Ex nA IIC T4 Gc | |
EAC approval | Russia: RU C-IT.MIII06.B.00129 | |
Marine approval | ||
Lloyd Register | 15/20021 | |
DNV GL Marine | TAA0000034 | |
American Bureau of Shipping | T1450280/UN | |
Bureau Veritas Marine | 22449/B0 BV |
Electrical specifications | ||
---|---|---|
Operating voltage | 660 V DC / 1000 V AC max. | |
Operating current | 1000 A max. | |
Mechanical specifications | ||
Degree of protection | IP66 (IP67 with O-ring) | |
Material | ||
Enclosure | Aluminum alloy | |
Ambient conditions | ||
Ambient temperature | -50 ... 60 °C (-58 ... 140 °F) -20 °C ... 60 °C (-4 °F ... 140 °F) GUB*5* and GUBX*5* | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | INERIS 14 ATEX 0035X | |
Group, category, type of protection, temperature class | ![]() Ex d IIC Gb Ex tb IIIC Db | |
International approvals | ||
IECEx approval | IECEx INE 14.0042X | |
General information | ||
Ordering information | This Solution will be delivered completely configured and assembled ready for use. For configuration details please contact Customer Service. | |
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
Electrical specifications | ||
---|---|---|
Operating voltage | 660 V DC / 1000 V AC max. | |
Operating current | 1000 A max. | |
Mechanical specifications | ||
Degree of protection | IP66 (IP67 with O-ring) | |
Material | ||
Enclosure | Aluminum alloy | |
Ambient conditions | ||
Ambient temperature | -50 ... 60 °C (-58 ... 140 °F) -20 °C ... 60 °C (-4 °F ... 140 °F) GUB*5* and GUBX*5* | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | INERIS 14 ATEX 0035X | |
Group, category, type of protection, temperature class | ![]() Ex d IIC Gb Ex tb IIIC Db | |
International approvals | ||
IECEx approval | IECEx INE 14.0042X | |
General information | ||
Ordering information | This Solution will be delivered completely configured and assembled ready for use. For configuration details please contact Customer Service. | |
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
Electrical specifications | ||
---|---|---|
Operating voltage | 660 V DC / 1000 V AC max. | |
Operating current | 1000 A max. | |
Mechanical specifications | ||
Degree of protection | IP66 (IP67 with O-ring) | |
Material | ||
Enclosure | Aluminum alloy | |
Glass | thermo-resistant tempered glass | |
Ambient conditions | ||
Ambient temperature | -50 ... 60 °C (-58 ... 140 °F) -20 °C ... 60 °C (-4 °F ... 140 °F) GUB*5* and GUBX*5* | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | INERIS 14 ATEX 0035X | |
Group, category, type of protection, temperature class | ![]() Ex d IIC Gb Ex tb IIIC Db | |
International approvals | ||
IECEx approval | IECEx INE 14.0042X | |
General information | ||
Ordering information | This Solution will be delivered completely configured and assembled ready for use. For configuration details please contact Customer Service. | |
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
Electrical specifications | ||
---|---|---|
Operating voltage | 660 V DC / 1000 V AC max. | |
Operating current | 1600 A max. | |
Mechanical specifications | ||
Enclosure cover | detachable , optional hinges | |
Cover fixing | Stainless steel hexagonal head screws | |
Degree of protection | IP66 (IP67 with O-ring) | |
Cable entry | see PDF data sheet | |
Defined entry area | see PDF data sheet | |
Material | ||
Enclosure | Aluminum alloy | |
Glass | thermo-resistant tempered glass | |
Finish | painted grey | |
Mass | see PDF data sheet | |
Mounting | see PDF data sheet | |
Ambient conditions | ||
Ambient temperature | see PDF data sheet | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | ||
Group, category, type of protection, temperature class | ![]() Ex d IIB+H2 Gb (EJB20 / 20 A in aluminum: Ex d IIB) Ex tb IIIC Db | |
International approvals | ||
IECEx approval | IECEx INE 14.0029X | |
Conformity | ||
Degree of protection | EN60529 | |
General information | ||
Ordering information | This Solution will be delivered completely configured and assembled ready for use. For configuration details please contact Customer Service. | |
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
Electrical specifications | ||
---|---|---|
Operating voltage | 660 V DC / 1000 V AC max. | |
Operating current | 1600 A max. | |
Mechanical specifications | ||
Enclosure cover | detachable , optional hinges | |
Cover fixing | Stainless steel hexagonal head screws | |
Degree of protection | IP66 (IP67 with O-ring) | |
Cable entry | see PDF data sheet | |
Defined entry area | see PDF data sheet | |
Material | ||
Enclosure | Aluminum alloy | |
Finish | painted grey | |
Mass | see PDF data sheet | |
Mounting | see PDF data sheet | |
Ambient conditions | ||
Ambient temperature | see PDF data sheet | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | ||
Group, category, type of protection, temperature class | ![]() Ex d IIB+H2 Gb (EJB20 / 20 A in aluminum: Ex d IIB) Ex tb IIIC Db | |
International approvals | ||
IECEx approval | IECEx INE 14.0029X | |
Conformity | ||
Degree of protection | EN60529 | |
General information | ||
Ordering information | This Solution will be delivered completely configured and assembled ready for use. For configuration details please contact Customer Service. | |
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
Electrical specifications | ||
---|---|---|
Operating voltage | 660 V DC / 1000 V AC max. | |
Operating current | 1000 A max. | |
Mechanical specifications | ||
Degree of protection | IP66 (IP67 with O-ring) | |
Material | ||
Enclosure | Aluminum alloy | |
Glass | thermo-resistant tempered glass | |
Ambient conditions | ||
Ambient temperature | -50 ... 60 °C (-58 ... 140 °F) -20 °C ... 60 °C (-4 °F ... 140 °F) GUB*5* and GUBX*5* | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | INERIS 14 ATEX 0035X | |
Group, category, type of protection, temperature class | ![]() Ex d IIC Gb Ex tb IIIC Db | |
International approvals | ||
IECEx approval | IECEx INE 14.0042X | |
General information | ||
Ordering information | This Solution will be delivered completely configured and assembled ready for use. For configuration details please contact Customer Service. | |
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
Electrical specifications | ||
---|---|---|
Operating voltage | 660 V DC / 1000 V AC max. | |
Operating current | 1000 A max. | |
Mechanical specifications | ||
Enclosure cover | threaded round cover | |
Cover fixing | flamepath thread | |
Degree of protection | IP66 (IP67 with O-ring) | |
Cable entry | see PDF data sheet | |
Defined entry area | see PDF data sheet | |
Material | ||
Enclosure | Aluminum alloy | |
Glass | thermo-resistant tempered glass | |
Finish | painted grey | |
Mass | see PDF data sheet | |
Grounding | M6 external/M5 internal grounding point | |
Ambient conditions | ||
Ambient temperature | -50 ... 60 °C (-58 ... 140 °F) -20 °C ... 60 °C (-4 °F ... 140 °F) GUB*5* and GUBX*5* | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | INERIS 14 ATEX 0035X | |
Group, category, type of protection, temperature class | ![]() Ex d IIC Gb Ex tb IIIC Db | |
International approvals | ||
IECEx approval | IECEx INE 14.0042X | |
Conformity | ||
Degree of protection | EN 60529 | |
General information | ||
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. | |
Accessories | ||
Optional accessories | see PDF data sheet |
Electrical specifications | ||
---|---|---|
Operating voltage | 660 V DC / 1000 V AC max. | |
Operating current | ASM enclosure: 500 A max. EJB enclosure: 1600 A max. GUB enclosure: 1000 A max. | |
Mechanical specifications | ||
Height | see PDF data sheet | |
Width | see PDF data sheet | |
Depth | see PDF data sheet | |
Fixing holes distance, height | see PDF data sheet | |
Fixing holes distance, width | see PDF data sheet | |
Enclosure cover | hinged | |
Cover fixing | see PDF data sheet | |
Fixing holes diameter | see PDF data sheet | |
Degree of protection | see PDF data sheet | |
Material | ||
Enclosure | aluminum and stainless steel | |
Finish | see PDF data sheet | |
Seal | see PDF data sheet | |
Mass | see PDF data sheet | |
Mounting | see PDF data sheet | |
Ambient conditions | ||
Ambient temperature | -20/-40 /-50 ... 55 °C (-4/-40/-58 ... 131 °F) details see PDF data sheet | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | see PDF data sheet | |
Group, category, type of protection, temperature class | ![]() ASM enclosures: Ex d IIB Gb, Ex tb IIIC Db EJB enclosures: Ex d IIB+H2 Gb, Ex tb IIIC Db EJB20 / EJB20A in aluminum: Ex d IIB Gb, Ex tb IIIC Db GUB enclosures: Ex d IIC Gb, Ex tb IIIC Db FS* Termination and Control Station: Ex de IIC T6, T5, T4 Gb Ex ib IIC T6, T5, T4 Gb Ex de ib IIC T6, T5, T4 Gb Ex tb IIIC T80 °C, T95 °C, T130 °C Db | |
International approvals | ||
IECEx approval | see PDF data sheet | |
Conformity | ||
Degree of protection | EN60529 | |
General information | ||
Ordering information | This device will be delivered completely configured and assembled ready for use. For configuration details please contact Customer Service. | |
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
Electrical specifications | ||
---|---|---|
Operating voltage | 660 V DC / 1000 V AC max. | |
Operating current | 1600 A max. | |
Mechanical specifications | ||
Enclosure cover | detachable , optional hinges | |
Cover fixing | Stainless steel hexagonal head screws | |
Degree of protection | IP66 (IP67 with O-ring) | |
Cable entry | see PDF data sheet | |
Defined entry area | see PDF data sheet | |
Material | ||
Enclosure | Aluminum alloy | |
Glass | thermo-resistant tempered glass | |
Finish | painted grey | |
Mass | see PDF data sheet | |
Mounting | see PDF data sheet | |
Grounding | M6 grounding points | |
Ambient conditions | ||
Ambient temperature | see PDF data sheet | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | ||
Group, category, type of protection, temperature class | ![]() Ex d IIB+H2 Gb (EJB20 / 20 A in aluminum: Ex d IIB) Ex tb IIIC Db | |
International approvals | ||
IECEx approval | IECEx INE 14.0029X | |
Conformity | ||
Degree of protection | EN60529 | |
General information | ||
Ordering information | This Solution will be delivered completely configured and assembled ready for use. For configuration details please contact Customer Service. | |
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
Electrical specifications | ||
---|---|---|
Operating voltage | 660 V DC / 1000 V AC max. | |
Operating current | 1600 A max. | |
Mechanical specifications | ||
Enclosure cover | detachable , optional hinges | |
Cover fixing | Stainless steel hexagonal head screws | |
Degree of protection | IP66/67 (IP67 with O-ring) | |
Cable entry | see PDF data sheet | |
Defined entry area | see PDF data sheet | |
Material | ||
Enclosure | AISI 316L stainless steel | |
Finish | shot peened | |
Mass | see PDF data sheet | |
Mounting | see PDF data sheet | |
Grounding | M6 grounding points | |
Ambient conditions | ||
Ambient temperature | see PDF data sheet | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | ||
Group, category, type of protection, temperature class | ![]() Ex d IIB+H2 Gb (EJB20 / 20 A in aluminum: Ex d IIB) Ex tb IIIC Db | |
International approvals | ||
IECEx approval | IECEx INE 14.0029X | |
Conformity | ||
Degree of protection | EN60529 | |
General information | ||
Ordering information | This Solution will be delivered completely configured and assembled ready for use. For configuration details please contact Customer Service. | |
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
Electrical specifications | ||
---|---|---|
Operating voltage | 660 V DC / 1000 V AC max. | |
Operating current | 1000 A max. | |
Mechanical specifications | ||
Enclosure cover | threaded round cover | |
Cover fixing | flamepath thread | |
Degree of protection | IP66 (IP67 with O-ring) | |
Cable entry | see PDF data sheet | |
Defined entry area | see PDF data sheet | |
Material | ||
Enclosure | Aluminum alloy | |
Glass | thermo-resistant tempered glass | |
Finish | painted grey | |
Mass | see PDF data sheet | |
Grounding | M6 grounding points | |
Ambient conditions | ||
Ambient temperature | -50 ... 60 °C (-58 ... 140 °F) -20 °C ... 60 °C (-4 °F ... 140 °F) GUB*5* and GUBX*5* | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | INERIS 14 ATEX 0035X | |
Group, category, type of protection, temperature class | ![]() Ex d IIC Gb Ex tb IIIC Db | |
International approvals | ||
IECEx approval | IECEx INE 14.0042X | |
Conformity | ||
Degree of protection | EN 60529 | |
General information | ||
Ordering information | This Solution will be delivered completely configured and assembled ready for use. For configuration details please contact Customer Service. | |
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. | |
Accessories | ||
Optional accessories | see PDF data sheet |