Атол 30Ф не включается (заводской брак)
Валерий
14 января 2022
Supply | ||
---|---|---|
Connection | terminal block TB3 (1-, 2+ 3-, 4+) | |
Rated voltage | 24 V DC , in consideration of rated voltage of used isolated barriers | |
Voltage drop | 0.9 V , voltage drop across the series diode on the termination board must be considered | |
Ripple | &le 10 % | |
Fusing | 4 A | |
Power dissipation | &le 500 mW , without modules | |
Reverse polarity protection | yes | |
Electrical specifications | ||
volt-free fault indication output | max. 30 V AC/40 V DC, 2 A | |
Redundancy | ||
Supply | Redundancy available. The supply for the modules is decoupled, monitored and fused. | |
Indicators/settings | ||
Display elements | LEDs PWR ON (power supply) - LED power supply I, green LED - LED power supply II, green LED LED Fault (fault indication), green LED | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Conformity | ||
Electromagnetic compatibility | NE 21:2012 For further information see system description. | |
Degree of protection | IEC 60529:2001 | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Connection | hazardous area connection (field side): pluggable screw terminals, blue safe area connection (control side): 37-pin Sub-D connector (male) | |
Core cross-section | 0.2 ... 2.5 mm2 (24 ... 12 AWG) | |
Material | housing: polycarbonate, 30 % glass fiber reinforced | |
Mass | approx. 900 g | |
Dimensions | 273 x 155 x 153 mm (L x W x H) , height including module assembly | |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | CESI 06 ATEX 022 | |
Group, category, type of protection | ![]() ![]() ![]() | |
Safe area | ||
Maximum safe voltage | 250 V (Attention! Um is no rated voltage.) | |
Galvanic isolation | ||
Field circuit/control circuit | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 50303:2000 | |
International approvals | ||
UL approval | ||
Control drawing | 116-0327 | |
IECEx approval | IECEx CES 06.0003 | |
Approved for | [Ex ia Ga] IIC [Ex ia Da] IIIC [Ex ia Ma] I |
Supply | ||
---|---|---|
Connection | terminal block TB3 (1-, 2+ 3-, 4+) | |
Rated voltage | 24 V DC , in consideration of rated voltage of used isolated barriers | |
Voltage drop | 0.9 V , voltage drop across the series diode on the termination board must be considered | |
Ripple | &le 10 % | |
Fusing | 4 A | |
Power dissipation | &le 500 mW , without modules | |
Reverse polarity protection | yes | |
Electrical specifications | ||
volt-free fault indication output | max. 30 V AC/40 V DC, 2 A | |
Redundancy | ||
Supply | Redundancy available. The supply for the modules is decoupled, monitored and fused. | |
Indicators/settings | ||
Display elements | LEDs PWR ON (power supply) - LED power supply I, green LED - LED power supply II, green LED LED Fault (fault indication), green LED | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Conformity | ||
Electromagnetic compatibility | NE 21:2012 For further information see system description. | |
Degree of protection | IEC 60529:2001 | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Connection | hazardous area connection (field side): pluggable screw terminals, blue safe area connection (control side): 37-pin Sub-D connector (male) | |
Core cross-section | 0.2 ... 2.5 mm2 (24 ... 12 AWG) | |
Material | housing: polycarbonate, 30 % glass fiber reinforced | |
Mass | approx. 900 g | |
Dimensions | 273 x 155 x 153 mm (L x W x H) , height including module assembly | |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | CESI 06 ATEX 022 | |
Group, category, type of protection | ![]() ![]() ![]() | |
Safe area | ||
Maximum safe voltage | 250 V (Attention! Um is no rated voltage.) | |
Galvanic isolation | ||
Field circuit/control circuit | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 50303:2000 | |
International approvals | ||
UL approval | ||
Control drawing | 116-0327 | |
IECEx approval | IECEx CES 06.0003 | |
Approved for | [Ex ia Ga] IIC [Ex ia Da] IIIC [Ex ia Ma] I |
Supply | ||
---|---|---|
Connection | terminal block TB3 (1-, 2+ 3-, 4+) | |
Rated voltage | 24 V DC , in consideration of rated voltage of used isolated barriers | |
Voltage drop | 0.9 V , voltage drop across the series diode on the termination board must be considered | |
Ripple | &le 10 % | |
Fusing | 2 A | |
Power dissipation | &le 500 mW , without modules | |
Reverse polarity protection | yes | |
Electrical specifications | ||
volt-free fault indication output | max. 30 V AC/40 V DC, 2 A | |
Redundancy | ||
Supply | Redundancy available. The supply for the modules is decoupled, monitored and fused. | |
Indicators/settings | ||
Display elements | LEDs PWR ON (power supply) - LED power supply I, green LED - LED power supply II, green LED LED Fault (fault indication), green LED | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Conformity | ||
Electromagnetic compatibility | NE 21:2012 For further information see system description. | |
Degree of protection | IEC 60529:2001 | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Connection | hazardous area connection (field side): pluggable screw terminals, blue safe area connection (control side): 37-pin Sub-D connector (male) | |
Core cross-section | 0.2 ... 2.5 mm2 (24 ... 12 AWG) | |
Material | housing: polycarbonate, 30 % glass fiber reinforced | |
Mass | approx. 500 g | |
Dimensions | 201 x 155 x 153 mm (7.9 x 6.1 x 6.0 inch) , height including module assembly | |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | CESI 11 ATEX 062 | |
Group, category, type of protection | ![]() ![]() ![]() | |
Safe area | ||
Maximum safe voltage | 250 V (Attention! Um is no rated voltage.) | |
Galvanic isolation | ||
Field circuit/control circuit | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 50303:2000 | |
International approvals | ||
CSA approval | ||
Control drawing | see control drawing of correspoding modules | |
IECEx approval | IECEx CES 11.0022 | |
Approved for | [Ex ia Ga] IIC [Ex ia Da] IIIC [Ex ia Ma] I |
Supply | ||
---|---|---|
Connection | terminal block TB3 (1-, 2+ 3-, 4+) | |
Rated voltage | 24 V DC , in consideration of rated voltage of used isolated barriers | |
Voltage drop | 0.9 V , voltage drop across the series diode on the termination board must be considered | |
Ripple | &le 10 % | |
Fusing | 4 A | |
Power dissipation | &le 500 mW , without modules | |
Reverse polarity protection | yes | |
Electrical specifications | ||
volt-free fault indication output | max. 30 V AC/40 V DC, 2 A | |
Redundancy | ||
Supply | Redundancy available. The supply for the modules is decoupled, monitored and fused. | |
Indicators/settings | ||
Display elements | LEDs PWR ON (power supply) - LED power supply I, green LED - LED power supply II, green LED LED Fault (fault indication), green LED | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Conformity | ||
Electromagnetic compatibility | NE 21:2012 For further information see system description. | |
Degree of protection | IEC 60529:2001 | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Connection | hazardous area connection (field side): pluggable screw terminals, blue safe area connection (control side): 37-pin Sub-D connector (male) | |
Core cross-section | 0.2 ... 2.5 mm2 (24 ... 12 AWG) | |
Material | housing: polycarbonate, 30 % glass fiber reinforced | |
Mass | approx. 1000 g | |
Dimensions | 357 x 155 x 153 mm (L x W x H) , height including module assembly | |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | CESI 11 ATEX 062 | |
Group, category, type of protection | ![]() ![]() ![]() | |
Safe area | ||
Maximum safe voltage | 250 V (Attention! Um is no rated voltage.) | |
Galvanic isolation | ||
Field circuit/control circuit | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 50303:2000 | |
International approvals | ||
CSA approval | ||
Control drawing | see control drawing of correspoding modules | |
IECEx approval | IECEx CES 11.0022 | |
Approved for | [Ex ia Ga] IIC [Ex ia Da] IIIC [Ex ia Ma] I |
Supply | ||
---|---|---|
Connection | terminal block TB3 (1-, 2+ 3-, 4+) | |
Rated voltage | 24 V DC , in consideration of rated voltage of used isolated barriers | |
Voltage drop | 0.9 V , voltage drop across the series diode on the termination board must be considered | |
Ripple | &le 10 % | |
Fusing | 4 A | |
Power dissipation | &le 500 mW , without modules | |
Reverse polarity protection | yes | |
Electrical specifications | ||
volt-free fault indication output | max. 30 V AC/40 V DC, 2 A | |
Redundancy | ||
Supply | Redundancy available. The supply for the modules is decoupled, monitored and fused. | |
Indicators/settings | ||
Display elements | LEDs PWR ON (power supply) - LED power supply I, green LED - LED power supply II, green LED LED Fault (fault indication), green LED | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Conformity | ||
Electromagnetic compatibility | NE 21:2012 For further information see system description. | |
Degree of protection | IEC 60529:2001 | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Connection | hazardous area connection (field side): pluggable screw terminals, blue safe area connection (control side): 37-pin Sub-D connector (male) | |
Core cross-section | 0.2 ... 2.5 mm2 (24 ... 12 AWG) | |
Material | housing: polycarbonate, 30 % glass fiber reinforced | |
Mass | approx. 1000 g | |
Dimensions | 357 x 155 x 153 mm (L x W x H) , height including module assembly | |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | CESI 11 ATEX 062 | |
Group, category, type of protection | ![]() ![]() ![]() | |
Safe area | ||
Maximum safe voltage | 250 V (Attention! Um is no rated voltage.) | |
Galvanic isolation | ||
Field circuit/control circuit | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 50303:2000 | |
International approvals | ||
CSA approval | ||
Control drawing | see control drawing of correspoding modules | |
IECEx approval | IECEx CES 11.0022 | |
Approved for | [Ex ia Ga] IIC [Ex ia Da] IIIC [Ex ia Ma] I |
Supply | ||
---|---|---|
Rated voltage | 24 V DC SELV/PELV | |
Fusing | T3A15 | |
Electrical specifications | ||
volt-free fault indication output | 30 V DC, 1 A | |
Redundancy | ||
Supply | Redundancy available. The supply for the modules is decoupled, monitored and fused. | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Conformity | ||
Degree of protection | IEC 60529 | |
Shock resistance | EN 60068-2-27 | |
Vibration resistance | EN 60068-2-6 | |
Ambient conditions | ||
Ambient temperature | -15 ... 50 °C (5 ... 122 °F) | |
Storage temperature | -15 ... 55 °C (5 ... 131 °F) | |
Relative humidity | &le 95 % , non-condensing | |
Shock resistance | 1 g , 16 ms (all space directions) | |
Vibration resistance | < 15 Hz, amplitude ± 2.5 mm/15 Hz | |
Mechanical specifications | ||
Degree of protection | IP20 |
Directive conformity | ||
---|---|---|
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Conformity | ||
Degree of protection | IEC 60529 | |
Shock resistance | EN 60068-2-27 | |
Vibration resistance | EN 60068-2-6 | |
Ambient conditions | ||
Ambient temperature | -15 ... 50 °C (5 ... 122 °F) | |
Storage temperature | -15 ... 55 °C (5 ... 131 °F) | |
Relative humidity | &le 95 % , non-condensing | |
Shock resistance | 1 g , 16 ms (all space directions) | |
Vibration resistance | < 15 Hz, amplitude ± 2.5 mm/15 Hz | |
Mechanical specifications | ||
Degree of protection | IP20 |
Directive conformity | ||
---|---|---|
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Conformity | ||
Degree of protection | IEC 60529 | |
Shock resistance | EN 60068-2-27 | |
Vibration resistance | EN 60068-2-6 | |
Ambient conditions | ||
Ambient temperature | -15 ... 50 °C (5 ... 122 °F) | |
Storage temperature | -15 ... 55 °C (5 ... 131 °F) | |
Relative humidity | &le 95 % , non-condensing | |
Shock resistance | 1 g , 16 ms (all space directions) | |
Vibration resistance | < 15 Hz, amplitude ± 2.5 mm/15 Hz | |
Mechanical specifications | ||
Degree of protection | IP20 |
Supply | ||
---|---|---|
Rated voltage | 24 V DC SELV/PELV | |
Fusing | T3A15 | |
Electrical specifications | ||
volt-free fault indication output | 30 V DC, 1 A | |
Redundancy | ||
Supply | Redundancy available. The supply for the modules is decoupled, monitored and fused. | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Conformity | ||
Degree of protection | IEC 60529 | |
Shock resistance | EN 60068-2-27 | |
Vibration resistance | EN 60068-2-6 | |
Ambient conditions | ||
Ambient temperature | -15 ... 50 °C (5 ... 122 °F) | |
Storage temperature | -15 ... 55 °C (5 ... 131 °F) | |
Relative humidity | &le 95 % , non-condensing | |
Shock resistance | 1 g , 16 ms (all space directions) | |
Vibration resistance | < 15 Hz, amplitude ± 2.5 mm/15 Hz | |
Mechanical specifications | ||
Degree of protection | IP20 |
Directive conformity | ||
---|---|---|
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Conformity | ||
Degree of protection | IEC 60529 | |
Shock resistance | EN 60068-2-27 | |
Vibration resistance | EN 60068-2-6 | |
Ambient conditions | ||
Ambient temperature | -15 ... 50 °C (5 ... 122 °F) | |
Storage temperature | -15 ... 55 °C (5 ... 131 °F) | |
Relative humidity | &le 95 % , non-condensing | |
Shock resistance | 1 g , 16 ms (all space directions) | |
Vibration resistance | < 15 Hz, amplitude ± 2.5 mm/15 Hz | |
Mechanical specifications | ||
Degree of protection | IP20 |
Supply | ||
---|---|---|
Rated voltage | 24 V DC SELV/PELV | |
Rated current | &le 100 mA per channel , total current consumption depends on number and type of devices | |
Fusing | T2A | |
Electrical specifications | ||
volt-free fault indication output | 30 V DC, 1 A | |
Redundancy | ||
Supply | Redundancy available. The supply for the modules is decoupled, monitored and fused. | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Conformity | ||
Degree of protection | IEC 60529 | |
Shock resistance | EN 60068-2-27 | |
Vibration resistance | EN 60068-2-6 | |
Ambient conditions | ||
Ambient temperature | -15 ... 50 °C (5 ... 122 °F) | |
Storage temperature | -15 ... 55 °C (5 ... 131 °F) | |
Relative humidity | &le 95 % , non-condensing | |
Shock resistance | 1 g , 16 ms (all space directions) | |
Vibration resistance | < 15 Hz, amplitude ± 2.5 mm/15 Hz | |
Mechanical specifications | ||
Degree of protection | IP20 |
Supply | ||
---|---|---|
Rated voltage | 24 V DC SELV/PELV | |
Fusing | T2A | |
Electrical specifications | ||
volt-free fault indication output | 30 V DC, 1 A | |
Redundancy | ||
Supply | Redundancy available. The supply for the modules is decoupled, monitored and fused. | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Conformity | ||
Degree of protection | IEC 60529 | |
Shock resistance | EN 60068-2-27 | |
Vibration resistance | EN 60068-2-6 | |
Ambient conditions | ||
Ambient temperature | -15 ... 50 °C (5 ... 122 °F) | |
Storage temperature | -15 ... 55 °C (5 ... 131 °F) | |
Relative humidity | &le 95 % , non-condensing | |
Shock resistance | 1 g , 16 ms (all space directions) | |
Vibration resistance | < 15 Hz, amplitude ± 2.5 mm/15 Hz | |
Mechanical specifications | ||
Degree of protection | IP20 |
Directive conformity | ||
---|---|---|
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Conformity | ||
Degree of protection | IEC 60529 | |
Shock resistance | EN 60068-2-27 | |
Vibration resistance | EN 60068-2-6 | |
Ambient conditions | ||
Ambient temperature | -15 ... 50 °C (5 ... 122 °F) | |
Storage temperature | -15 ... 55 °C (5 ... 131 °F) | |
Relative humidity | &le 95 % , non-condensing | |
Shock resistance | 1 g , 16 ms (all space directions) | |
Vibration resistance | < 15 Hz, amplitude ± 2.5 mm/15 Hz | |
Mechanical specifications | ||
Degree of protection | IP20 |
Supply | ||
---|---|---|
Rated voltage | 24 V DC | |
Fusing | T2A | |
Electrical specifications | ||
volt-free fault indication output | max. 30 V AC/40 V DC, 2 A | |
Redundancy | ||
Supply | Redundancy available. The supply for the modules is decoupled, monitored and fused. | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Conformity | ||
Degree of protection | IEC 60529 | |
Shock resistance | EN 60068-2-27 | |
Vibration resistance | EN 60068-2-6 | |
Ambient conditions | ||
Ambient temperature | -15 ... 50 °C (5 ... 122 °F) | |
Storage temperature | -15 ... 55 °C (5 ... 131 °F) | |
Relative humidity | &le 95 % , non-condensing | |
Shock resistance | 1 g , 16 ms (all space directions) | |
Vibration resistance | < 15 Hz, amplitude ± 2.5 mm/15 Hz | |
Mechanical specifications | ||
Degree of protection | IP20 |
Supply | ||
---|---|---|
Rated voltage | 24 V DC SELV/PELV | |
Fusing | T2A | |
Electrical specifications | ||
volt-free fault indication output | max. 30 V AC/40 V DC, 2 A | |
Redundancy | ||
Supply | Redundancy available. The supply for the modules is decoupled, monitored and fused. | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Conformity | ||
Degree of protection | IEC 60529 | |
Shock resistance | EN 60068-2-27 | |
Vibration resistance | EN 60068-2-6 | |
Ambient conditions | ||
Ambient temperature | -15 ... 50 °C (5 ... 122 °F) | |
Storage temperature | -15 ... 55 °C (5 ... 131 °F) | |
Relative humidity | &le 95 % , non-condensing | |
Shock resistance | 1 g , 16 ms (all space directions) | |
Vibration resistance | < 15 Hz, amplitude ± 2.5 mm/15 Hz | |
Mechanical specifications | ||
Degree of protection | IP20 |
Supply | ||
---|---|---|
Rated voltage | 24 V DC SELV/PELV | |
Rated current | &le 0.6 A per channel , total current consumption depends on number and type of devices | |
Fusing | 6.3 A | |
Electrical specifications | ||
volt-free fault indication output | max. 30 V AC/40 V DC, 2 A | |
Redundancy | ||
Supply | Redundancy available. The supply for the modules is decoupled, monitored and fused. | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Conformity | ||
Degree of protection | IEC 60529 | |
Shock resistance | EN 60068-2-27 | |
Vibration resistance | EN 60068-2-6 | |
Ambient conditions | ||
Ambient temperature | -15 ... 50 °C (5 ... 122 °F) | |
Storage temperature | -15 ... 55 °C (5 ... 131 °F) | |
Relative humidity | &le 95 % , non-condensing | |
Shock resistance | 1 g , 16 ms (all space directions) | |
Vibration resistance | < 15 Hz, amplitude ± 2.5 mm/15 Hz | |
Mechanical specifications | ||
Degree of protection | IP20 |
Supply | ||
---|---|---|
Rated voltage | 24 V DC | |
Rated current | &le 0.6 A | |
Fusing | 6.3 A | |
Electrical specifications | ||
volt-free fault indication output | max. 30 V AC/40 V DC, 2 A | |
Redundancy | ||
Supply | Redundancy available. The supply for the modules is decoupled, monitored and fused. | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Conformity | ||
Degree of protection | IEC 60529 | |
Shock resistance | EN 60068-2-27 | |
Vibration resistance | EN 60068-2-6 | |
Ambient conditions | ||
Ambient temperature | -15 ... 50 °C (5 ... 122 °F) | |
Storage temperature | -15 ... 55 °C (5 ... 131 °F) | |
Relative humidity | &le 95 % , non-condensing | |
Shock resistance | 1 g , 16 ms (all space directions) | |
Vibration resistance | < 15 Hz, amplitude ± 2.5 mm/15 Hz | |
Mechanical specifications | ||
Degree of protection | IP20 |
Directive conformity | ||
---|---|---|
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Conformity | ||
Degree of protection | IEC 60529 | |
Shock resistance | EN 60068-2-27 | |
Vibration resistance | EN 60068-2-6 | |
Ambient conditions | ||
Ambient temperature | -15 ... 50 °C (5 ... 122 °F) | |
Storage temperature | -15 ... 55 °C (5 ... 131 °F) | |
Relative humidity | &le 95 % , non-condensing | |
Shock resistance | 1 g , 16 ms (all space directions) | |
Vibration resistance | < 15 Hz, amplitude ± 2.5 mm/15 Hz | |
Mechanical specifications | ||
Degree of protection | IP20 |
Function and system design | ||
---|---|---|
Measuring principle | The sensor of the device transmits ultrasonic pulses in the direction of the product surface. There, the ultrasonic pulses are reflected back and received by the sensor. The device measures the time between pulse transmission and reception. The instrument uses the time (and the velocity of sound) to calculate the distance between the sensor membrane and the product surface. As the device knows the empty distance from a user entry, the device calculate the level. | |
Equipment architecture | 4 ... 20 mA output with HART protocol system integration via PROFIBUS PA | |
Input characteristics | ||
Measured variable | distance between the sensor membrane and the product surface using the linearization function, the device calculate - level in any units - volume in any units - flow across measuring weirs or open channels in any units | |
Measurement range | LUC-M10: max. 5 m (16.4 ft) in fluids and 2 m (6.6 ft) in bulk materials LUC-M20: max. 8 m (26.2 ft) in fluids and 3,5 m (11.5 ft) in bulk materials LUC-M30: max. 15 m (49.2 ft) in fluids and 7 m (23 ft) in bulk materials LUC-M40: max. 10 m (32.8 ft) in fluids and 5 m (16.4 ft) in bulk materials | |
Output characteristics | ||
Output signal | according to the instrument version: - 4 ... 20 mA with HART protocol - PROFIBUS PA | |
Auxiliary energy | ||
Electrical connection | terminal compartment: In the F12 housing, the terminals are located underneath the housing cover, in the T12 housing, they are under the cover of the separate terminal compartment. cable gland: M20x1.5 (recommended cable diameter 6 ... 10 mm (0.24 ... 0.4 inch)) cable entry G1/2 or NPT1/2 PROFIBUS PA: M12 plug connector | |
Supply voltage | 2-wire HART (standard): - current consumption 4 ... 20 mA - min. terminal voltage 14 V (at 4 mA), 8 V (at 20 mA) - max. terminal voltage 36 V 4-wire HART: - DC version: voltage 10.5 ... 32 V, max. load 600 &Omega - AC version: 90 ... 253 V, max. load 600 &Omega PROFIBUS PA: 9 ... 32 V DC for additional information see technical information | |
Power consumption | 2-wire: 51 ... 800 mW 4-wire AC: max. 4 VA 4-wire DC: 0.6 ... 1 W | |
Current consumption | 2-wire devices: - HART: 3.6 ... 22 mA - PROFIBUS PA: max. 13 mA | |
Measurement accuracy | ||
Reaction time | depends on the parameter settings: - min. 0.5 s for 4-wire devices - min. 2 s for 2-wire devices | |
Reference operating conditions | temperature = 20 °C (68 °F) pressure = 1013 mbarabs humidity = 50 % ideal reflective surface (e. g. calm, smooth fluid surface) no interference reflections within signal beam set application parameters: - tank shape = flat ceiling - medium property = liquid - process conditions = calm surface | |
Measured value resolution | LUC-M10, LUC-M20: 1 mm (0.04 inch) LUC-M30, LUC-M40: 2 mm (0.08 inch) | |
Measuring frequency | 2-wire devices: max. 0.5 Hz 4-wire devices: max. 2 Hz dependent on the type of device and the parameter settings | |
Maximum measured error | typical specifications for reference operating conditions (include linearity, repeatability, and hysteresis): ± 2 mm (0.08 inch) or 0.2% of set measuring range (empty calibration)1) 1) whichever is greater | |
Operating conditions | ||
Installation conditions | see technical information (TI) | |
Ambient conditions | ||
Ambient temperature | -40 ... 80 °C (-40 ... 176 °F) , For further information see technical information. | |
Storage temperature | -40 ... 80 °C (-40 ... 176 °F) | |
Resistance to alternating temperature cycles | Nb test: +80 °C/- 40 °C (353 K/233 K), 1 K/min, 100 cycles | |
Vibration resistance | 20 ... 2000 Hz, 1 (m/s2)2/Hz 3 x 100 min | |
Process conditions | ||
Process temperature | -40 ... 80 °C (-40 ... 176 °F) (233 ... 353 K), a temperature sensor is integrated in the sensor for correction of the temperature-dependent time-of-flight | |
Process pressure (static pressure) | LUC-M10, LUC-M20: 0.7 ... 3 barabs LUC-M30, LUC-M40: 0.7 ... 2.5 barabs | |
Mechanical specifications | ||
Degree of protection | with closed housing, tested according to - IP68, NEMA 6P (24 h at 1.83 m under water surface) - IP66, NEMA 4X with open housing: IP20, NEMA 1 (also ingress protection of the display) | |
Mechanical construction | ||
Dimensions | see section dimensions | |
Mass | LUC-M10: approx. 2.5 kg LUC-M20: approx. 2.6 kg LUC-M30: approx. 3.5 kg LUC-M40: approx. 3 kg | |
Material | material in contact with process: - LUC-M10, LUC-M20: sensor PVDF, seal EPDM - LUC-M30: sensor UP and stainless steel 1.4571/316Ti, seal EPDM, flange PP or stainless steel 1.4571/316Ti - LUC-M40: sensor PVDF, seal Viton or EPDM, flange PP, PVDF or stainless steel 1.4535/316L housing: aluminum, seawater resistant, chromated, powder-coated cover: - aluminum, for version without on-site display - inspection glass for version with on-site display | |
Certificates and approvals | ||
Explosion-hazardous area | KEMA 05 ATEX 1111, KEMA 05 ATEX 1112 , for additional certificates see www.pepperl-fuchs.com | |
Type of protection | ![]() ![]() ![]() ![]() ![]() ![]() |
General specifications | ||
---|---|---|
Sensing range | 0.3 ... 4 m , with fluids | |
Transducer frequency | approx. 85 kHz | |
Indicators/operating means | ||
LED green | Power on | |
LED red | 2 Hz flashing: error | |
Electrical specifications | ||
Operating voltage | 20 ... 30 V DC , ripple 10 %SS | |
Power consumption | &le 1200 mW | |
Output | ||
Output type | 1 analog output 4 ... 20 mA, RL &le 500 Ohm, error &ge 21 mA 1 voltage output 0 ... 10 V, RL &ge 1000 Ohm, error &ge 10.5 V | |
Resolution | 2 mm | |
Deviation of the characteristic curve | 0.5 % of upper limit of measuring range | |
Approvals and certificates | ||
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Degree of protection | IP65 | |
Connection | 5-pin V15 (M12 x 1) connector | |
Material | ||
Housing | PBT, polypropylene | |
Transducer | PTFE (diaphragm surface) | |
Mass | 220 g | |
Mounting | G1½A connection |
General specifications | ||
---|---|---|
Sensing range | 0.3 ... 4 m , with fluids | |
Transducer frequency | approx. 85 kHz | |
Indicators/operating means | ||
LED green | Power on | |
LED red | 2 Hz flashing: error | |
Electrical specifications | ||
Operating voltage | 20 ... 30 V DC , ripple 10 %SS | |
Power consumption | &le 1200 mW | |
Output | ||
Output type | 1 analog output 4 ... 20 mA, RL &le 500 Ohm, error &ge 21 mA 1 voltage output 0 ... 10 V, RL &ge 1000 Ohm, error &ge 10.5 V | |
Resolution | 2 mm | |
Deviation of the characteristic curve | 0.5 % of upper limit of measuring range | |
Approvals and certificates | ||
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Degree of protection | IP65 | |
Connection | 5-pin V15 (M12 x 1) connector | |
Material | ||
Housing | PBT, stainless steel 1.4571 | |
Transducer | PTFE (diaphragm surface) | |
Mass | 220 g | |
Mounting | G1½A connection |
General specifications | ||
---|---|---|
Sensing range | 0.3 ... 4 m , with fluids | |
Transducer frequency | approx. 85 kHz | |
Indicators/operating means | ||
LED green | Power on | |
LED red | 2 Hz flashing: error | |
Electrical specifications | ||
Operating voltage | 20 ... 30 V DC , ripple 10 %SS | |
Power consumption | &le 1200 mW | |
Output | ||
Output type | 1 analog output 4 ... 20 mA, RL &le 500 Ohm, error &ge 21 mA 1 voltage output 0 ... 10 V, RL &ge 1000 Ohm, error &ge 10.5 V | |
Resolution | 2 mm | |
Deviation of the characteristic curve | 0.5 % of upper limit of measuring range | |
Approvals and certificates | ||
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Degree of protection | IP65 | |
Connection | 5-pin V15 (M12 x 1) connector | |
Material | ||
Housing | PBT, polypropylene | |
Transducer | PTFE (diaphragm surface) | |
Mass | 220 g | |
Mounting | screwed connection 1½" NPT |
General specifications | ||
---|---|---|
Sensing range | 0.3 ... 4 m , with fluids | |
Transducer frequency | approx. 85 kHz | |
Indicators/operating means | ||
LED green | Power on | |
LED red | 2 Hz flashing: error | |
Electrical specifications | ||
Operating voltage | 20 ... 30 V DC , ripple 10 %SS | |
Power consumption | &le 1200 mW | |
Output | ||
Output type | 1 analog output 4 ... 20 mA, RL &le 500 Ohm, error &ge 21 mA 1 voltage output 0 ... 10 V, RL &ge 1000 Ohm, error &ge 10.5 V | |
Resolution | 2 mm | |
Deviation of the characteristic curve | 0.5 % of upper limit of measuring range | |
Approvals and certificates | ||
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Degree of protection | IP65 | |
Connection | 5-pin V15 (M12 x 1) connector | |
Material | ||
Housing | PBT, stainless steel 1.4571 | |
Transducer | PTFE (diaphragm surface) | |
Mass | 220 g | |
Mounting | screwed connection 1½" NPT |
Slots | ||
---|---|---|
Occupied slots | 1 | |
Supply | ||
Connection | backplane bus | |
Rated voltage | 12 V DC , only in connection with the power supplies LB9*** | |
Power dissipation | 2 W | |
Power consumption | 3 W | |
Internal bus | ||
Connection | backplane bus | |
Interface | manufacturer-specific bus to standard com unit | |
Analog input | ||
Number of channels | 4 | |
Suitable field devices | ||
Field device | pressure converter | |
Field device [2] | flow converter | |
Field device [3] | level converter | |
Field device [4] | Temperature Converter | |
Field device interface | ||
Connection | 2-wire transmitter | |
Connection | terminals 1+, 2- 3+, 4- 5+, 6- 7+, 8- | |
Transmitter supply voltage | min. 15 V at 20 mA 21.5 V at 4 mA | |
Input resistance | 15 &Omega | |
Line fault detection | can be switched on/off for each channel via configuration tool , configurable via configuration tool | |
Short-circuit | factory setting: > 21 mA Can be parameterized in the range 0 ... 22 mA | |
Open-circuit | factory setting: < 3.6 mA Can be parameterized in the range 0 ... 22 mA | |
HART communication | yes | |
HART secondary variable | yes | |
Analog output | ||
Number of channels | 4 | |
Suitable field devices | ||
Field device | Proportional Valve | |
Field device [2] | I/P converters | |
Field device [3] | on-site display | |
Connection | terminals 1+, 2- 3+, 4- 5+, 6- 7+, 8- | |
Line fault detection | can be switched on/off for each channel via configuration tool , configurable via configuration tool | |
Short-circuit | factory setting: < 50 &Omega configurable between 0 ... 26 mA | |
Open-circuit | deviation of preset output value > 0.5 mA | |
Load | 750 &Omega max. | |
HART communication | yes | |
HART secondary variable | yes | |
Watchdog | output off 0.5 s after serious fault | |
Digital input | ||
Number of channels | 4 | |
Sensor interface | ||
Connection [2] | volt-free contact | |
Connection | terminals 1+, 2- 3+, 4- 5+, 6- 7+, 8- | |
Digital signals (active) | ||
Switching point: ON | > 2.1 mA | |
Switching point: OFF | < 1.2 mA | |
Line fault detection | can be switched on/off for each channel via configuration tool | |
Connection | mechanical switch with additional resistors (see connection diagram) | |
Short-circuit | > 7 mA | |
Open-circuit | < 0.1 mA | |
Digital output | ||
Number of channels | 4 | |
Suitable field devices | ||
Field device | Solenoid Valve | |
Field device [2] | audible alarm | |
Field device [3] | visual alarm | |
Connection | terminals 1+, 2-, 3+, 4-, 5+, 6-, 7+, 8- | |
Drive capability | 12 V / 22 mA | |
Open loop voltage | min. 22.7 V | |
Current limit | 22 mA | |
Internal resistor | 385 &Omega | |
Line fault detection | can be switched on/off for each channel via configuration tool | |
Test current | 0.4 mA | |
Short-circuit | < 50 &Omega | |
Open-circuit | < 0.2 mA | |
Transfer characteristics | ||
Deviation | ||
After calibration | 0.1 % of the signal range at 20 °C (68 °F) | |
Refresh time | approx. 100 ms (4 channels) | |
Indicators/settings | ||
LED indicator | Power LED (P) green: supply Diagnostic LED (I) red: module fault , red flashing: communication error , white: fixed parameter set (parameters from com unit are ignored) , white flashing: requests parameters from com unit Status LED (1-4) red: line fault (lead breakage or short circuit) , yellow: state of digital I/O (0/1) Configuration LED (AI, AO, DI, DO) white: selected channel mode | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2006 | |
Conformity | ||
Electromagnetic compatibility | NE 21:2007 | |
Degree of protection | IEC 60529:2000 | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) , 70 °C (non-Ex) | |
Storage temperature | -25 ... 85 °C (-13 ... 185 °F) | |
Shock resistance | shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18 | |
Vibration resistance | frequency range 10 ... 150 Hz transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g 10 cycles frequency range 5 ... 100 Hz transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g 90 minutes at each resonance | |
Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 | |
Mechanical specifications | ||
Degree of protection | IP20 (module) , mounted on backplane | |
Connection | removable front connector with screw flange (accessory) wiring connection via spring terminals (0.14 ... 1.5 mm2) or screw terminals (0.08 ... 1.5 mm2) | |
Mass | approx. 100 g | |
Dimensions | 16 x 100 x 102 mm (0.63 x 3.9 x 4 inch) | |
Data for application in connection with hazardous areas | ||
Certificate | BVS 12 ATEX E 115 X | |
Marking | ![]() | |
Galvanic isolation | ||
Rated voltage | 250 V field circuits to control and supply circuits | |
Input/power supply, internal bus | safe electrical isolation acc. to EN 60079-11, voltage peak value 375 V | |
Output/power supply, internal bus | safe electrical isolation acc. to EN 60079-11, voltage peak value 375 V | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2009 EN 60079-11:2007 EN 60079-15:2010 | |
International approvals | ||
ATEX approval | BVS 12 ATEX E 115 X | |
IECEx approval | BVS 11.0068X | |
Approved for | Ex nAc [ic] IIC T4 | |
Marine approval | ||
Lloyd Register | 15/20021 | |
Bureau Veritas Marine | 22449/B0 BV |
Slots | ||
---|---|---|
Occupied slots | 1 | |
Supply | ||
Connection | backplane bus | |
Rated voltage | 12 V DC , only in connection with the power supplies LB9*** | |
Power dissipation | 2 W | |
Power consumption | 3 W | |
Internal bus | ||
Connection | backplane bus | |
Interface | manufacturer-specific bus to standard com unit | |
Analog input | ||
Number of channels | 4 | |
Suitable field devices | ||
Field device | pressure converter | |
Field device [2] | flow converter | |
Field device [3] | level converter | |
Field device [4] | Temperature Converter | |
Field device interface | ||
Connection | 2-wire transmitter | |
Connection | terminals 1+, 2- 3+, 4- 5+, 6- 7+, 8- | |
Transmitter supply voltage | min. 15 V at 20 mA 21.5 V at 4 mA | |
Input resistance | 15 &Omega | |
Line fault detection | can be switched on/off for each channel via configuration tool , configurable via configuration tool | |
Short-circuit | factory setting: > 21 mA Can be parameterized in the range 0 ... 22 mA | |
Open-circuit | factory setting: < 3.6 mA Can be parameterized in the range 0 ... 22 mA | |
HART communication | yes | |
HART secondary variable | yes | |
Analog output | ||
Number of channels | 4 | |
Suitable field devices | ||
Field device | Proportional Valve | |
Field device [2] | I/P converters | |
Field device [3] | on-site display | |
Connection | terminals 1+, 2- 3+, 4- 5+, 6- 7+, 8- | |
Line fault detection | can be switched on/off for each channel via configuration tool , configurable via configuration tool | |
Short-circuit | factory setting: < 50 &Omega configurable between 0 ... 26 mA | |
Open-circuit | deviation of preset output value > 0.5 mA | |
Load | 750 &Omega max. | |
HART communication | yes | |
HART secondary variable | yes | |
Watchdog | output off 0.5 s after serious fault | |
Digital input | ||
Number of channels | 4 | |
Sensor interface | ||
Connection [2] | volt-free contact | |
Connection | terminals 1+, 2- 3+, 4- 5+, 6- 7+, 8- | |
Digital signals (active) | ||
Switching point: ON | > 2.1 mA | |
Switching point: OFF | < 1.2 mA | |
Line fault detection | can be switched on/off for each channel via configuration tool | |
Connection | mechanical switch with additional resistors (see connection diagram) | |
Short-circuit | > 7 mA | |
Open-circuit | < 0.1 mA | |
Digital output | ||
Number of channels | 4 | |
Suitable field devices | ||
Field device | Solenoid Valve | |
Field device [2] | audible alarm | |
Field device [3] | visual alarm | |
Connection | terminals 1+, 2-, 3+, 4-, 5+, 6-, 7+, 8- | |
Drive capability | 12 V / 22 mA | |
Open loop voltage | min. 22.7 V | |
Current limit | 22 mA | |
Internal resistor | 385 &Omega | |
Line fault detection | can be switched on/off for each channel via configuration tool | |
Test current | 0.4 mA | |
Short-circuit | < 50 &Omega | |
Open-circuit | < 0.2 mA | |
Transfer characteristics | ||
Deviation | ||
After calibration | 0.1 % of the signal range at 20 °C (68 °F) | |
Refresh time | approx. 100 ms (4 channels) | |
Indicators/settings | ||
LED indicator | Power LED (P) green: supply Diagnostic LED (I) red: module fault , red flashing: communication error , white: fixed parameter set (parameters from com unit are ignored) , white flashing: requests parameters from com unit Status LED (1-4) red: line fault (lead breakage or short circuit) , yellow: state of digital I/O (0/1) Configuration LED (AI, AO, DI, DO) white: selected channel mode | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2006 | |
Conformity | ||
Electromagnetic compatibility | NE 21:2007 | |
Degree of protection | IEC 60529:2000 | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Storage temperature | -25 ... 85 °C (-13 ... 185 °F) | |
Shock resistance | shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18 | |
Vibration resistance | frequency range 10 ... 150 Hz transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g 10 cycles frequency range 5 ... 100 Hz transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g 90 minutes at each resonance | |
Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 | |
Mechanical specifications | ||
Degree of protection | IP20 when mounted on backplane | |
Connection | removable front connector with screw flange (accessory) wiring connection via spring terminals (0.14 ... 1.5 mm2) or screw terminals (0.08 ... 1.5 mm2) | |
Mass | approx. 100 g | |
Dimensions | 16 x 100 x 102 mm (0.63 x 3.9 x 4 inch) | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | BVS 11 ATEX E 116 X | |
Marking | ![]() ![]() ![]() | |
Input | ||
Voltage | 27 V | |
Current | 87 mA | |
Power | 575 mW (linear characteristic) | |
Output | ||
Voltage | 27 V | |
Current | 87 mA | |
Power | 575 mW (linear characteristic) | |
Galvanic isolation | ||
Rated voltage | 250 V field circuits to control and supply circuits | |
Input/power supply, internal bus | safe electrical isolation acc. to EN 60079-11, voltage peak value 375 V | |
Output/power supply, internal bus | safe electrical isolation acc. to EN 60079-11, voltage peak value 375 V | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2009 EN 60079-11:2007 EN 60079-15:2010 EN 60079-26:2007 EN 61241-11:2006 EN 50303:2000 | |
International approvals | ||
ATEX approval | BVS 11 ATEX E 116X | |
UL approval | E106378 | |
IECEx approval | BVS 11.0068X | |
Approved for | Ex nAc [ia] IIC T4 [Ex ia] IIIC [Ex ia] I | |
Marine approval | ||
Lloyd Register | 15/20021 | |
Bureau Veritas Marine | 22449/B0 BV |
General specifications | ||
---|---|---|
Design / Mounting | Cabinet installation | |
Electrical specifications | ||
Rated voltage | 33 V | |
Rated current | 500 mA | |
Voltage protection level | ||
Line/Line | max. 58 V category C1/C2 8/20µsec max. 50 V category C3 1kV/µsec max. 51 V category B2 10/700µsec max. 55 V category D1 10/350µsec | |
Line/Earth | max. 1400 V category C1/C2 8/20µsec max. 1100 V category C1/C2 1kV/µsec max. 1000 V category B2 10/700µsec max. 1300 V category D1 10/350µsec | |
Screen/Shield directly grounded | max. 25 V category C1/C2 8/20µsec max. 20 V category D1 10/350µsec | |
Screen/Shield indirectly grounded (via GDT) | max. 700 V category C1/C2 8/20µsec max. 600 V category C3 1kV/µsec max. 500 V category B2 10/700µsec max. 600 V category D1 10/350µsec | |
Reaction time | ||
Line/Line | max. 1 ns | |
Line/Earth | max. 100 ns | |
Screen/Shield-Earth | max. 100 ns | |
Overstressed fault mode | acc. IEC 61643-21 line inoperable mode 3 lines 1 and 2 at 15,5kA (8/20µsec) lines 3 and 4 at 30kA (8/20µsec) | |
Series resistance in line | 1 &Omega +/- 5 % | |
Impulse durability | ||
Per line | 1 kA category D1 10/350µsec , 5 kA category C1/C2 8/20µsec | |
Screen/Shield directly grounded | 5 kA category D1 10/350µsec | |
Screen/Shield indirectly grounded (via GDT) | 4 kA category D1 10/350µsec , 10 kA category C1/C2 8/20µsec | |
Capacitance | ||
Line/Line | 800 pF | |
Line/Earth | 16 pF | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 | |
Standard conformity | ||
Degree of protection | IEC 60529 | |
Fieldbus standard | IEC 61158-2 | |
Climatic conditions | IEC 60721 | |
Shock resistance | EN 60068-2-27 | |
Vibration resistance | EN 60068-2-6 | |
Surge protection | IEC 61643-21 | |
Ambient conditions | ||
Ambient temperature | -50 ... 80 °C (-58 ... 176 °F) | |
Storage temperature | -50 ... 85 °C (-58 ... 185 °F) | |
Relative humidity | &le 95 % non-condensing | |
Shock resistance | 15 g 11 ms | |
Vibration resistance | 1 g , 10 ... 150 Hz | |
Mechanical specifications | ||
Connection type | screw terminals | |
Core cross-section | flexible wire 2.5 mm2 solid wire max. 4 mm2 | |
Housing material | Polyamide PA 6.6 | |
Degree of protection | IP20 | |
Mass | Protection Module 20 g , base module 40 g | |
Mounting | 35 mm DIN mounting rail | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | KEMA 09 ATEX 0191 X | |
Marking | ![]() | |
Voltage | 30 V | |
Current | 500 mA | |
Internal capacitance | negligible 0 nF | |
Internal inductance | negligible 0 µH | |
Certificate | KEMA 09 ATEX 0190 X | |
Marking | ![]() ![]() | |
Voltage | 33 V | |
Current | 500 mA | |
Internal capacitance | negligible 0 nF | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012 , EN 60079-11:2012 , EN 60079-15:2010 , EN 60079-26:2007 | |
International approvals | ||
CSA approval | CSA 2437472 | |
Control drawing | 116-0361 | |
Approved for | Class I, Zone 1, AEx/Ex ia IIC T4...T6, Class I, Zone 2, AEx nC IIC T4...T6, Class I, Zone 2, Ex nL IIC T4...T6, Class I, Zone 2, AEx/Ex nA IIC T4...T6 Class I Div. 1, GP A, B, C, D T4...T6, Class I Div. 2, GP A, B, C, D T4...T6, Class I Div. 2, GP A, B, C, D T4...T6 | |
IECEx approval | IECEx KEM 09.0088X | |
Approved for | Ex ia [ia Ga] IIC T4/T5/T6 Gb , Ex ic IIC T4/T5/T6 Gc , Ex nA IIC T4/T5/T6 Gc | |
Certificates and approvals | ||
Marine approval | pending |
General specifications | ||
---|---|---|
Design / Mounting | Cabinet installation | |
Electrical specifications | ||
Rated voltage | 33 V | |
Rated current | 500 mA | |
Voltage protection level | ||
Line/Line | max. 58 V category C1/C2 8/20µsec max. 50 V category C3 1kV/µsec max. 51 V category B2 10/700µsec max. 55 V category D1 10/350µsec | |
Line/Earth | max. 1400 V category C1/C2 8/20µsec max. 1100 V category C1/C2 1kV/µsec max. 1000 V category B2 10/700µsec max. 1300 V category D1 10/350µsec | |
Screen/Shield directly grounded | max. 25 V category C1/C2 8/20µsec max. 20 V category D1 10/350µsec | |
Screen/Shield indirectly grounded (via GDT) | max. 700 V category C1/C2 8/20µsec max. 600 V category C3 1kV/µsec max. 500 V category B2 10/700µsec max. 600 V category D1 10/350µsec | |
Reaction time | ||
Line/Line | max. 1 ns | |
Line/Earth | max. 100 ns | |
Screen/Shield-Earth | max. 100 ns | |
Overstressed fault mode | acc. IEC 61643-21 line inoperable mode 3 lines 1 and 2 at 15,5kA (8/20µsec) lines 3 and 4 at 30kA (8/20µsec) | |
Series resistance in line | 1 &Omega +/- 5 % | |
Impulse durability | ||
Per line | 1 kA category D1 10/350µsec , 5 kA category C1/C2 8/20µsec | |
Screen/Shield directly grounded | 5 kA category D1 10/350µsec | |
Screen/Shield indirectly grounded (via GDT) | 4 kA category D1 10/350µsec , 10 kA category C1/C2 8/20µsec | |
Capacitance | ||
Line/Line | 800 pF | |
Line/Earth | 16 pF | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 | |
Standard conformity | ||
Degree of protection | IEC 60529 | |
Fieldbus standard | IEC 61158-2 | |
Climatic conditions | IEC 60721 | |
Shock resistance | EN 60068-2-27 | |
Vibration resistance | EN 60068-2-6 | |
Surge protection | IEC 61643-21 | |
Ambient conditions | ||
Ambient temperature | -50 ... 80 °C (-58 ... 176 °F) | |
Storage temperature | -50 ... 85 °C (-58 ... 185 °F) | |
Relative humidity | &le 95 % non-condensing | |
Shock resistance | 15 g 11 ms | |
Vibration resistance | 1 g , 10 ... 150 Hz | |
Mechanical specifications | ||
Connection type | screw terminals | |
Core cross-section | flexible wire 2.5 mm2 solid wire max. 4 mm2 | |
Housing material | Polyamide PA 6.6 | |
Degree of protection | IP20 | |
Mass | Protection Module 20 g , base module 40 g | |
Mounting | 35 mm DIN mounting rail | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | KEMA 09 ATEX 0191 X | |
Marking | ![]() | |
Voltage | 30 V | |
Current | 500 mA | |
Internal capacitance | negligible 0 nF | |
Internal inductance | negligible 0 µH | |
Certificate | KEMA 09 ATEX 0190 X | |
Marking | ![]() ![]() | |
Voltage | 33 V | |
Current | 500 mA | |
Internal capacitance | negligible 0 nF | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012 , EN 60079-11:2012 , EN 60079-15:2010 , EN 60079-26:2007 | |
International approvals | ||
CSA approval | CSA 2437472 | |
Control drawing | 116-0361 | |
Approved for | Class I, Zone 1, AEx/Ex ia IIC T4...T6, Class I, Zone 2, AEx nC IIC T4...T6, Class I, Zone 2, Ex nL IIC T4...T6, Class I, Zone 2, AEx/Ex nA IIC T4...T6 Class I Div. 1, GP A, B, C, D T4...T6, Class I Div. 2, GP A, B, C, D T4...T6, Class I Div. 2, GP A, B, C, D T4...T6 | |
IECEx approval | IECEx KEM 09.0088X | |
Approved for | Ex ia [ia Ga] IIC T4/T5/T6 Gb , Ex ic IIC T4/T5/T6 Gc , Ex nA IIC T4/T5/T6 Gc | |
Certificates and approvals | ||
Marine approval | pending |
General specifications | ||
---|---|---|
Design / Mounting | Cabinet installation | |
Fieldbus interface | ||
Self current consumption | max. 6 mA (for version SCP-LBF-IA1.36.IE.1) , max. 0 mA (for version SCP-LBF-IA1.36.IE.0) | |
Indicators/operating means | ||
LED ERR | green flashing: status OK , red flashing: maintenance required (for version SCP-LBF-IA1.36.IE.1) | |
Electrical specifications | ||
Rated voltage | 36 V | |
Rated current | 250 mA | |
Voltage protection level | ||
Line/Line | max. 50 V category B2 10/700µsec , 25 A max. 53 V category C1 8/20µsec , 150 A max. 55 V category C2 8/20µsec , 150 A max. 46 V category C3 1kV/µsec , 10 A | |
Line/Earth | max. 980 V category B2 10/700µsec , 50 A per line max. 800 V category C1 8/20µsec , 50 A per line max. 1450 V category C2 8/20µsec , 5 kA per line max. 1200 V category C3 1kV/µsec , 50 A per line max. 980 V category D1 10/350µsec , 500 A per line | |
Screen/Shield indirectly grounded (via GDT) | max. 500 V category B2 10/700µsec , 100 A max. 600 V category C1 8/20µsec , 500 A max. 700 V category C2 8/20µsec , 10 kA max. 550 V category C3 1kV/µsec , 100 A max. 570 V category D1 10/350µsec , 1 kA | |
Reaction time | ||
Line/Line | max. 1 ns | |
Line/Earth | max. 100 ns | |
Screen/Shield-Earth | max. 100 ns | |
Overstressed fault mode | acc. IEC 61643-21 line inoperable mode 2 | |
Impulse durability | ||
Per line | 5 kA category C2 8/20µsec | |
Screen/Shield indirectly grounded (via GDT) | 1 kA category D1 10/350µsec 10 kA category C2 8/20µsec | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 | |
Standard conformity | ||
Electromagnetic compatibility | NAMUR NE 21 | |
Degree of protection | IEC 60529 | |
Fieldbus standard | IEC 61158-2 | |
Climatic conditions | IEC 60721 | |
Shock resistance | EN 60068-2-27 | |
Vibration resistance | EN 60068-2-6 | |
Surge protection | IEC 61643-21 | |
Ambient conditions | ||
Ambient temperature | -40 ... 70 °C (-40 ... 158 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Relative humidity | &le 95 % non-condensing | |
Shock resistance | 15 g 11 ms | |
Vibration resistance | 1 g , 10 ... 150 Hz | |
Corrosion resistance | acc. to ISA-S71.04-1985, severity level G3 | |
Mechanical specifications | ||
Connection type | screw terminals | |
Core cross-section | flexible wire 2.5 mm2 solid wire max. 4 mm2 | |
Housing material | Polyamide PA 6.6 | |
Degree of protection | IP20 | |
Mass | 45 g | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | SIRA 12 ATEX 2128X | |
Marking | ![]() | |
Voltage | 24 V | |
Current | 500 mA | |
Internal capacitance | 2 nF | |
Internal inductance | 0.1 µH | |
Certificate | SIRA 12 ATEX 4176X | |
Marking | ![]() ![]() | |
Voltage | 33 V | |
Current | 600 mA | |
Internal capacitance | 2 nF | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012 , EN 60079-11:2012 , EN 60079-15:2010 , EN 60079-26:2007 | |
Supplementary information | FISCO field device | |
International approvals | ||
CSA approval | CoC 2595441 | |
Control drawing | 116-0365 | |
Approved for | Class I, Division 1, Groups A, B, C, D T4 Class I, Zone 0, Ex ia IIC T4 Class I, Zone 2, Ex ic IIC T4 Class I, Zone 0, AEx ia IIC T4 Class I, Zone 2, AEx ic IIC T4 Class I, Division 2, Groups A, B, C, D T4 Class I, Zone 2, Ex nL IIC T4 Class I, Zone 2, Ex na IIC T4 Class I, Zone 2, AEx nAc IIC T4 | |
IECEx approval | IECEx SIR 12.0051X | |
Approved for | Ex ia IIC T4 | |
Certificates and approvals | ||
Marine approval | DNV A-14038 |
General specifications | ||
---|---|---|
Design / Mounting | Cabinet installation | |
Fieldbus interface | ||
Self current consumption | max. 6 mA (for version SCP-LBF-IA1.36.IE.1) , max. 0 mA (for version SCP-LBF-IA1.36.IE.0) | |
Indicators/operating means | ||
LED ERR | green flashing: status OK , red flashing: maintenance required (for version SCP-LBF-IA1.36.IE.1) | |
Electrical specifications | ||
Rated voltage | 36 V | |
Rated current | 250 mA | |
Voltage protection level | ||
Line/Line | max. 50 V category B2 10/700µsec , 25 A max. 53 V category C1 8/20µsec , 150 A max. 55 V category C2 8/20µsec , 150 A max. 46 V category C3 1kV/µsec , 10 A | |
Line/Earth | max. 980 V category B2 10/700µsec , 50 A per line max. 800 V category C1 8/20µsec , 50 A per line max. 1450 V category C2 8/20µsec , 5 kA per line max. 1200 V category C3 1kV/µsec , 50 A per line max. 980 V category D1 10/350µsec , 500 A per line | |
Screen/Shield indirectly grounded (via GDT) | max. 500 V category B2 10/700µsec , 100 A max. 600 V category C1 8/20µsec , 500 A max. 700 V category C2 8/20µsec , 10 kA max. 550 V category C3 1kV/µsec , 100 A max. 570 V category D1 10/350µsec , 1 kA | |
Reaction time | ||
Line/Line | max. 1 ns | |
Line/Earth | max. 100 ns | |
Screen/Shield-Earth | max. 100 ns | |
Overstressed fault mode | acc. IEC 61643-21 line inoperable mode 2 | |
Impulse durability | ||
Per line | 5 kA category C2 8/20µsec | |
Screen/Shield indirectly grounded (via GDT) | 1 kA category D1 10/350µsec 10 kA category C2 8/20µsec | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 | |
Standard conformity | ||
Electromagnetic compatibility | NAMUR NE 21 | |
Degree of protection | IEC 60529 | |
Fieldbus standard | IEC 61158-2 | |
Climatic conditions | IEC 60721 | |
Shock resistance | EN 60068-2-27 | |
Vibration resistance | EN 60068-2-6 | |
Surge protection | IEC 61643-21 | |
Ambient conditions | ||
Ambient temperature | -40 ... 70 °C (-40 ... 158 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Relative humidity | &le 95 % non-condensing | |
Shock resistance | 15 g 11 ms | |
Vibration resistance | 1 g , 10 ... 150 Hz | |
Corrosion resistance | acc. to ISA-S71.04-1985, severity level G3 | |
Mechanical specifications | ||
Connection type | screw terminals | |
Core cross-section | flexible wire 2.5 mm2 solid wire max. 4 mm2 | |
Housing material | Polyamide PA 6.6 | |
Degree of protection | IP20 | |
Mass | 45 g | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | SIRA 12 ATEX 2128X | |
Marking | ![]() | |
Voltage | 24 V | |
Current | 500 mA | |
Internal capacitance | 2 nF | |
Internal inductance | 0.1 µH | |
Certificate | SIRA 12 ATEX 4176X | |
Marking | ![]() ![]() | |
Voltage | 33 V | |
Current | 600 mA | |
Internal capacitance | 2 nF | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012 , EN 60079-11:2012 , EN 60079-15:2010 , EN 60079-26:2007 | |
Supplementary information | FISCO field device | |
International approvals | ||
CSA approval | CoC 2595441 | |
Control drawing | 116-0365 | |
Approved for | Class I, Division 1, Groups A, B, C, D T4 Class I, Zone 0, Ex ia IIC T4 Class I, Zone 2, Ex ic IIC T4 Class I, Zone 0, AEx ia IIC T4 Class I, Zone 2, AEx ic IIC T4 Class I, Division 2, Groups A, B, C, D T4 Class I, Zone 2, Ex nL IIC T4 Class I, Zone 2, Ex na IIC T4 Class I, Zone 2, AEx nAc IIC T4 | |
IECEx approval | IECEx SIR 12.0051X | |
Approved for | Ex ia IIC T4 | |
Certificates and approvals | ||
Marine approval | DNV A-14038 |
General specifications | ||
---|---|---|
Design / Mounting | Cabinet installation | |
Fieldbus interface | ||
Self current consumption | max. 6 mA (for version TCP-LBF-IA1.36.IE.1) , max. 0 mA (for version TCP-LBF-IA1.36.IE.0) | |
Indicators/operating means | ||
LED ERR | green flashing: status OK , red flashing: maintenance required , (for version TCP-LBF-IA1.36.IE.1) | |
Electrical specifications | ||
Rated voltage | 36 V | |
Rated current | 600 mA | |
Voltage protection level | ||
Line/Line | max. 50 V category B2 10/700µsec , 25 A max. 50 V category C1 8/20µsec , 300 A max. 55 V category C2 8/20µsec , 5 kA max. 46 V category C3 1kV/µsec , 10 A | |
Line/Earth | max. 1060 V category B2 10/700µsec , 50 A per line max. 800 V category C1 8/20µsec , 300 A per line max. 1.5 kV category C2 8/20µsec , 5 kA per line max. 1.3 kV category C3 1kV/µsec , 50 A per line max. 1080 V category D1 10/350µsec , 500 A per line | |
Screen/Shield indirectly grounded (via GDT) | max. 500 V category B2 10/700µsec , 100 A max. 600 V category C1 8/20µsec , 500 A max. 720 V category C2 8/20µsec , 10 kA max. 550 V category C3 1kV/µsec , 100 A max. 570 V category D1 10/350µsec , 1 kA | |
Reaction time | ||
Line/Line | max. 1 ns | |
Line/Earth | max. 100 ns | |
Screen/Shield-Earth | max. 100 ns | |
Overstressed fault mode | acc. IEC 61643-21 line inoperable mode 3 | |
Series resistance in line | 2 &Omega +/- 5 % | |
Impulse durability | ||
Per line | 5 kA category C2 8/20µsec | |
Screen/Shield indirectly grounded (via GDT) | 1 kA category D1 10/350µsec 10 kA category C2 8/20µsec | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 | |
Standard conformity | ||
Electromagnetic compatibility | NAMUR NE 21 | |
Degree of protection | IEC 60529 | |
Fieldbus standard | IEC 61158-2 | |
Climatic conditions | IEC 60721 | |
Shock resistance | EN 60068-2-27 | |
Vibration resistance | EN 60068-2-6 | |
Surge protection | IEC 61643-21 | |
Ambient conditions | ||
Ambient temperature | -40 ... 70 °C (-40 ... 158 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Relative humidity | &le 95 % non-condensing | |
Shock resistance | 15 g 11 ms | |
Vibration resistance | 1 g , 10 ... 150 Hz | |
Corrosion resistance | acc. to ISA-S71.04-1985, severity level G3 | |
Mechanical specifications | ||
Connection type | screw terminals | |
Core cross-section | flexible wire 2.5 mm2 solid wire max. 4 mm2 | |
Housing material | Polyamide PA 6.6 | |
Degree of protection | IP20 | |
Mass | 80 g | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | SIRA 12 ATEX 2128X | |
Marking | ![]() | |
Voltage | 24 V | |
Current | 500 mA | |
Internal capacitance | 2 nF | |
Internal inductance | 0.1 µH | |
Certificate | SIRA 12 ATEX 4176X | |
Marking | ![]() ![]() | |
Voltage | 33 V | |
Current | 600 mA | |
Internal capacitance | 2 nF | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012 , EN 60079-11:2012 , EN 60079-15:2010 , EN 60079-26:2007 | |
Supplementary information | FISCO field device | |
International approvals | ||
CSA approval | CoC 2595441 | |
Control drawing | 116-0365 | |
Approved for | Class I, Division 1, Groups A, B, C, D T4 Class I, Zone 0, Ex ia IIC T4 Class I, Zone 2, Ex ic IIC T4 Class I, Zone 0, AEx ia IIC T4 Class I, Zone 2, AEx ic IIC T4 Class I, Division 2, Groups A, B, C, D T4 Class I, Zone 2, Ex nL IIC T4 Class I, Zone 2, Ex na IIC T4 Class I, Zone 2, AEx nAc IIC T4 | |
IECEx approval | IECEx SIR 12.0051X | |
Approved for | Ex ia IIC T4 | |
Certificates and approvals | ||
Marine approval | DNV A-14038 |
Товаров: 0
На сумму: 0