Датчик предельной вибрации Vibration Limit Switch LVL-M2C Pepperl+Fuchs

Каталожный номер 271511
Узнать цену
Скидки от суммы заказа
Гарантия от производителя
Ходовые товары на складе
Наличный и безналичный расчет
Доставка по России и СНГ
Добавлено в корзину!

Товаров: 0

На сумму: 0

Продолжить покупки
Оформить заказ
Описание
Оплата
Доставка
Гарантия
Инструкции

Описание товара

General specifications
Function principlelimit detection
Maximum or minimum detection in tanks or pipelines containing all types of liquids including use in explosion hazardous areas. Particularly suited to very aggressive liquids thanks to high degree of corrosion protection.
Measuring methodThe forks of the sensors vibrate at their intrinsic frequency. This frequency is reduced when covered with liquid.
The change in frequency then activates the limit switch.
Construction typedevice with extension tube, coated with ECTFE
Supply
Rated voltageelectronic insert FEL50A (PA): 9 ... 32 V DC
electronic insert FEL51 (AC): 253 V AC, 50/60 Hz
electronic insert FEL52 (E5): 10 ... 55 V DC
electronic insert FEL54 (WA): 19 ... 253 V AC, 50/60 Hz or 19 ... 55 V DC
electronic insert FEL55 (SI): 11 ... 36 V DC, PLC
electronic insert FEL56 (N1), FEL58 (N2): isolating amplifier acc. to EN 60947-5-6 (NAMUR)
Current consumptionelectronic insert FEL52 (E5): max. 15 mA
Electrical specifications
Surge protectionelectronic insert FEL51 (AC), electronic insert FEL52 (E5), electronic insert FEL54 (WA), electronic insert FEL55 (SI): overvoltage category III
Input
Switching pointsee section switch point
Measured variablelimit level (limit value)
Measurement rangedepends on mounting point and pipe extension up to 3000 mm , larger sizes on request
Output
Switching delaywhen fork is covered: approx. 0.5 s, when fork is exposed: approx. 1.0 s (other switching times on request)
additionally configurable for PROFIBUS PA (electronic insert FEL50A (PA)): 0.5 ... 60 s
Switch behaviourswitch-over for minimum/maximum residual current safety on electronic insert
MAX = maximum safety:
The output switches to the power fail response when the fork is covered.
for use with overspill protection for example
MIN = minimum safety:
The output switches to the power fail response when the fork is exposed.
for use with dry running protection for example
When switching on the power supply the output assumes the alarm signal. After max. 2 s it assumes the correct switching mode.
Conformity
Electromagnetic compatibilityNE 21
Degree of protectionIEC 60529
Vibration resistanceEN 60068-2-6
Climate classDIN EN 60068-2-38/IEC 68-2-38
Measurement accuracy
Reference operating conditionsambient temperature: 23 °C (73.4 °F), medium temperature: 23 °C (73.4 °F),
product density: 1 g/cm3 (water), viscosity: 1 mm2/s, medium pressure pe: 0 bar,
sensor mounting: vertical from above, density switch: to > 0.7 g/cm3
Maximum measured errormax. ± 1 mm, specified by mounting position
Non-repeatability0.1 mm
Hysteresisapprox. 2 mm
Influence of medium densitymax. +4.8 ... -3.5 mm (0.5 ... 1.5 g/cm3)
Influence of medium temperaturemax. 1.4 ... -2.8 mm (-40 ... 120 °C (-40 ... 248 °F))
Influence of medium pressuremax. 0 ... -2 mm (0 ... 40 bar)
Operating conditions
Installation conditions
Installation positionwith short pipe (up to 500 mm (19.7 inch)) any position, with long pipe vertical
Process conditions
Medium temperature-50 ... 150 °C (-58 ... 302 °F) , exceptions see process connections
Medium pressurepe = -1 ... 40 bar (-14.5 ... 580.2 psi) over the entire temperature range , exceptions see process connections
Test pressuremax. 100 bar (1.5 times the medium pressure pe), no function during test pressure, burst pressure of diaphragm 200 bar
Pressure surgemax. 20 bar/s
Thermal shock resistancemax. 120 °C/s
State of aggregationliquid
Densitymin. 0.5 g/cm3 , other density settings on request
Viscositymax. 10000 mm2/s
Solid contents< &empty5 mm
Ambient conditions
Ambient temperature-50 ... 70 °C (-58 ... 158 °F) , function with reduced data values
see section ambient temperature
Storage temperature-50 ... 80 °C (-58 ... 176 °F)
Vibration resistance10 ... 50 Hz, 0.15 mm, 100 cycles
Mechanical specifications
Degree of protectionpolyester, steel, and aluminum housing: IP66/IP67
Connectionelectronic inserts: cross section max. 2.5 mm2, lace in end splice in acc. with DIN 46228
ground lead in housing: cross section max. 2.5 mm2
external equipotential bonding: cross section 4 mm2
Materialwetted parts:
- process connection and extension pipe: 1.4435/316L with ECTFE coating
- vibration fork: 1.4435/316L with ECTFE coating
housings:
- polyester housing: PBT-FR with PBT-FR cover or with PA12 cover with sight glass, cover seal: EPDM
- stainless steel housing: 1.4301/304, cover seal: silicone
- aluminum housing: EN-AC-AlSi10Mg, plastic-coated, cover seal: EPDM
cable gland: polyamide or brass, nickel-plated
temperature spacer: 1.4435/316L
flameproof bushing: 1.4435/316L
Surface qualityRa < 3.2 µm
Mass800 g , basic weight: compact version (length type II), electronic insert, plastic housing, without flange, additional weight is dependent on extension tube, housing and process connection
process connections:
- A3H 1000 g, A5H 1500 g, A6H 2400 g, A6I 3200 g, A8H 4900 g
- H35 1400 g, H65 2400 g, H71 1600 g, H75 3200 g, H95 5900 g, HA3 5600 g
- J1H 1700 g
extension tube, temperature spacer, flameproof bushing:
- BK* 900 g/m
- CK* 2300 g/100 in
- DKA 100 g, DKB 700 g, DKC 800 g
Dimensionshousing: diameter max. 85 mm, height max. 173 mm
temperature separator, flameproof bushing: additional length L 140 mm
process connection: length L min. 115 mm
extension: any length L from 148 ... 3000 mm, larger sizes on request
extension: length type II, for vertical installation from above same switching point as Vibracon LVL2
vibration fork: width 20.6 mm, fork width 6.5 mm, length 25 mm
Process connectionflanges to EN 1092-1 from DN25, to ANSI B 16.5 from 1 inch, to JIS B 2238 (RF) from DN50
For further information see type code.
Data for application in connection with hazardous areas
EU-Type Examination Certificatesee instruction manuals (SI)
International approvals
FM approvalsee control drawings (ZD)
CSA approvalsee control drawings (ZD)
IECEx approvalsee instruction manuals (SI)
Certificates and approvals
SIL classificationup to SIL2 acc. to IEC 61508
Overspill protectionsee approval (ZE)
Accessories
Designationsee technical information (TI)

Характеристики

Производитель Pepperl+Fuchs

 

Важная информация

Все информационные материалы, представленные на сайте, носят справочный характер и не могут в полной мере передавать достоверную информацию о свойствах и характеристиках товара.

Фотография на сайте служит дополнительным источником для определения совместимости запчастей с Вашим оборудованием, и не может являться основным. Основной источник по совместимости запчастей - актуальная документация производителя оборудования, из которой значимой информацией для заказа являются: название запчасти и каталожный номер.

Запасные части и комплектующие подбираются самостоятельно покупателем строго по каталожным номерам из официальных деталировок производителей. В случае, если номенклатура товара совпадает с фактически поставленной, но не подходит на оборудование - в ее замене или возврате может быть отказано.

Цены на сайте имеют информационный характер и могут отличаться от цен в коммерческом предложении.

Клиенты

ООО "Зипстор"
127282, Страна, Московская область, Москва, ул. Полярная, 33, стр. 3
+7 (800) 551-66-17
info@zipstore.ru