Каталожный номер: 240639
General specifications
Signal typeAnalog output
Functional safety related parameters
Safety Integrity Level (SIL)SIL 2
Supply
ConnectionPower Rail or terminals 9+, 10-
Rated voltage19 ... 30 V DC
Ripple&le 10 %
Rated current&le 30 mA
Power dissipation&le 600 mW
Power consumption&le 700 mW
Input
Connection sidecontrol side
Connectionterminals 5-, 6+
Input signal4 ... 20 mA limited to approx. 30 mA
Voltage dropdepending on switch configuration
open loop voltage of the control system < 23 V: approx. 6 V at 20 mA
open loop voltage of the control system < 27 V: approx. 10 V at 20 mA
Input resistance> 100 k&Omega, with field wiring open
Output
Connection sidefield side
Connectionterminals 1+, 2-
Current4 ... 20 mA
Load0 ... 650 &Omega
Voltage&ge 13 V at 20 mA
Ripple20 mV rms
Transfer characteristics
Accuracy0.1 %
Deviationat 20 °C (68 °F), 0/4 ... 20 mA
&le ± 0.1 % incl. non-linearity and hysteresis
Frequency rangebandwidth at 0.5 Vss signal 0 ... 3 kHz (-3 dB)
Rise time10 to 90 % &le 100 ms
Indicators/settings
Display elementsLED
Control elementsDIP-switch
Configurationvia DIP switches
Labelingspace for labeling at the front
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013 (industrial locations)
Conformity
Electromagnetic compatibilityNE 21:2006
Degree of protectionIP20 according to EN 60529
Ambient conditions
Ambient temperature-20 ... 60 °C (-4 ... 140 °F)
Mechanical specifications
Degree of protectionIP20
Connectionspring terminals
Massapprox. 100 g
Dimensions12.5 x 114 x 124 mm (0.5 x 4.5 x 4.9 inch) , housing type A2
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001
Узнать цену
Каталожный номер: 126755
General specifications
Signal typeAnalog output
Functional safety related parameters
Safety Integrity Level (SIL)SIL 2
Supply
ConnectionPower Rail or terminals 14+, 15-
Rated voltage20 ... 35 V DC
Ripplewithin the supply tolerance
Power dissipation0.8 W at 20 mA into 10 V (equivalent to 500 &Omega) load
Power consumption1 W at 20 mA
Input
Connection sidecontrol side
Connectionterminals 7-, 8+, (9+)
Voltage dropapprox. 4 V or internal resistance 200 &Omega at 20 mA
Input resistance> 100 k&Omega, when wiring resistance in the field > 16 V (equivalent to 800 &Omega at 20 mA)
Current4 ... 20 mA limited to approx. 25 mA
Output
Connection sidefield side
Connectionterminals 1+, 2-
Current4 ... 20 mA
Load100 ... 700 &Omega
Voltage&ge 14 V at 20 mA
Transfer characteristics
Accuracy0.05 %
Rise time< 100 µs , 10 ... 90 % step change
Indicators/settings
Display elementsLEDs
Labelingspace for labeling at the front
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013 (industrial locations)
Conformity
Electromagnetic compatibilityNE 21:2011
Degree of protectionIEC 60529:2001
Ambient conditions
Ambient temperature-20 ... 60 °C (-4 ... 140 °F)
Mechanical specifications
Degree of protectionIP20
Connectionscrew terminals
Massapprox. 150 g
Dimensions20 x 124 x 115 mm (0.8 x 4.9 x 4.5 inch) , housing type B2
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001
Розничная цена
347.65 $ с НДС 33028 с НДС
array(31) { ["id"]=> string(5) "95368" ["product_id"]=> string(6) "151998" ["id_1c"]=> NULL ["sku"]=> string(6) "126755" ["sort"]=> string(1) "0" ["name"]=> string(0) "" ["image_id"]=> NULL ["price"]=> float(33028) ["primary_price"]=> string(10) "347.652728" ["purchase_price"]=> float(0) ["compare_price"]=> float(0) ["count"]=> string(5) "0.000" ["available"]=> string(1) "1" ["stock_base_ratio"]=> NULL ["order_count_min"]=> NULL ["order_count_step"]=> NULL ["status"]=> string(1) "1" ["dimension_id"]=> NULL ["file_name"]=> string(0) "" ["file_size"]=> string(1) "0" ["file_description"]=> NULL ["virtual"]=> string(1) "0" ["ymleasyimport_price_id"]=> NULL ["id_xmlimport"]=> NULL ["stock"]=> array(3) { [1]=> string(5) "0.000" [3]=> string(5) "0.000" [4]=> string(5) "0.000" } ["unconverted_currency"]=> string(3) "USD" ["currency"]=> string(3) "RUB" ["frontend_price"]=> float(33028) ["unconverted_price"]=> float(347.65) ["frontend_compare_price"]=> float(0) ["unconverted_compare_price"]=> float(0) }
В корзину
Купить в 1 клик
Каталожный номер: 126756
General specifications
Signal typeAnalog output
Functional safety related parameters
Safety Integrity Level (SIL)SIL 2
Supply
ConnectionPower Rail or terminals 14+, 15-
Rated voltage20 ... 35 V DC
Ripplewithin the supply tolerance
Power dissipation1.4 W at 20 mA into 10 V (equivalent to 500 &Omega) load
Power consumption1.8 W at 20 mA
Input
Connection sidecontrol side
Connectionterminals 7-, 8+, (9+) 10-, 11+, (12+)
Voltage dropapprox. 4 V or internal resistance 200 &Omega at 20 mA
Input resistance> 100 k&Omega, when wiring resistance in the field > 16 V (equivalent to 800 &Omega at 20 mA)
Current4 ... 20 mA limited to approx. 25 mA
Output
Connection sidefield side
Connectionterminals 1+, 2- 4+, 5-
Current4 ... 20 mA
Load100 ... 700 &Omega
Voltage&ge 14 V at 20 mA
Transfer characteristics
Accuracy0.05 %
Rise time< 100 µs , 10 ... 90 % step change
Indicators/settings
Display elementsLEDs
Control elementsDIP-switch
Configurationvia DIP switches
Labelingspace for labeling at the front
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013 (industrial locations)
Conformity
Electromagnetic compatibilityNE 21:2011
Degree of protectionIEC 60529:2001
Ambient conditions
Ambient temperature-20 ... 60 °C (-4 ... 140 °F)
Mechanical specifications
Degree of protectionIP20
Connectionscrew terminals
Massapprox. 150 g
Dimensions20 x 124 x 115 mm (0.8 x 4.9 x 4.5 inch) , housing type B2
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001
Розничная цена
527 $ с НДС 50067 с НДС
array(31) { ["id"]=> string(5) "95369" ["product_id"]=> string(6) "151999" ["id_1c"]=> NULL ["sku"]=> string(6) "126756" ["sort"]=> string(1) "0" ["name"]=> string(0) "" ["image_id"]=> NULL ["price"]=> float(50067) ["primary_price"]=> string(10) "527.005242" ["purchase_price"]=> float(0) ["compare_price"]=> float(0) ["count"]=> string(5) "0.000" ["available"]=> string(1) "1" ["stock_base_ratio"]=> NULL ["order_count_min"]=> NULL ["order_count_step"]=> NULL ["status"]=> string(1) "1" ["dimension_id"]=> NULL ["file_name"]=> string(0) "" ["file_size"]=> string(1) "0" ["file_description"]=> NULL ["virtual"]=> string(1) "0" ["ymleasyimport_price_id"]=> NULL ["id_xmlimport"]=> NULL ["stock"]=> array(3) { [1]=> string(5) "0.000" [3]=> string(5) "0.000" [4]=> string(5) "0.000" } ["unconverted_currency"]=> string(3) "USD" ["currency"]=> string(3) "RUB" ["frontend_price"]=> float(50067) ["unconverted_price"]=> float(527) ["frontend_compare_price"]=> float(0) ["unconverted_compare_price"]=> float(0) }
В корзину
Купить в 1 клик
Каталожный номер: 194658
Supply
Rated voltage19.2 ... 35 V DC
Rated current150 ... 100 mA
Power dissipation3 W
Ethernet Interface
Intrinsically safe port10 BASE-T/100 BASE-TX
Non-intrinsically safe port10 BASE-T/100 BASE-TX
Connection type2 x RJ-45 , IEC 60603-7
Connector pinoutsocket TIA/EIA-568-B
Transfer rate10/100 Mbit/s , Auto-Negotiation
Operating modeHalf/Full Duplex
Cable typeCAT5e S/FTP AWG 24, Installation cable, L/R ratio max. 10 µH/&Omega of all strand combinations
I.S. cable lengthtyp. 100 m/20 °C
Total cable lengthtyp. 200 m/20 °C
Number of isolatorsmax. 2 in series connection
Indicators/operating means
LED PWRgreen: Power on
LED ACTyellow: communication active
LED 10/100yellow ON: Transfer rate 100 MBit/s , OFF: 10 MBit/s
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013
Standard conformity
Galvanic isolationEN 50020
Degree of protectionIEC 60529
Climatic conditionsDIN IEC 721
Shock resistanceEN 60068-2-27
Vibration resistanceEN 60068-2-6
EthernetIEEE 802.3 , IEEE 802.3u
Ambient conditions
Ambient temperature-40 ... 60 °C (-40 ... 140 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Relative humidity&le 95 % non-condensing
Shock resistance15 g 11 ms
Vibration resistance1 g 10 ... 150 Hz
Pollution degreemax. 2, according to IEC 60664
Mechanical specifications
Connection typeTerminals
Core cross-sectionup to 2.5 mm2
Housing materialPolyamide PA 66
Degree of protectionIP20 according to EN 60529
Mass195 g
MountingDIN rail mounting
Data for application in connection with hazardous areas
EU-Type Examination CertificatePTB 07 ATEX 2025 X
MarkingEx-Hexagon II (1) G [Ex ia Ga] IIB ,
Ex-Hexagon II (1) D [Ex ia Da] IIIC ,
Ex-Hexagon II 3(1)G Ex nA [ia Ga] IIB T4 Gc Ex-Hexagon II 3 (1D) G Ex nA [ia IIIC Da] IIB T4 Gc Ex-Hexagon I (M1) [Ex ia Ma] I
Supply
Maximum safe voltage253 V AC
Directive conformity
Directive 2014/34/EUEN 60079-0:2012 , EN 60079-11:2012 , EN 60079-15:2010
International approvals
CSA approvalCSA 15.70016295
Control drawing116-B032
Approved forClass I, Zone 2, AEx/Ex nA [ia Ga] IIB T4 Gc Class I, Zone 2, AEx/Ex nA [ia Da IIIC] IIB T4 Gc
IECEx approvalIECEx PTB 09.0053X
Approved for[Ex ia Ga] IIB
[Ex ia Da] IIIC
Ex nA [ia Ga] IIB T4 Gc
Ex nA [ia IIIC Da] IIB T4 Gc
[Ex ia Ma] I
Certificates and approvals
PatentsThis product may be covered by the following patent: US7,687,791
Розничная цена
1781.6 $ с НДС 169258 с НДС
array(31) { ["id"]=> string(5) "95424" ["product_id"]=> string(6) "152054" ["id_1c"]=> NULL ["sku"]=> string(6) "194658" ["sort"]=> string(1) "0" ["name"]=> string(0) "" ["image_id"]=> NULL ["price"]=> float(169258) ["primary_price"]=> string(11) "1781.609708" ["purchase_price"]=> float(0) ["compare_price"]=> float(0) ["count"]=> string(5) "0.000" ["available"]=> string(1) "1" ["stock_base_ratio"]=> NULL ["order_count_min"]=> NULL ["order_count_step"]=> NULL ["status"]=> string(1) "1" ["dimension_id"]=> NULL ["file_name"]=> string(0) "" ["file_size"]=> string(1) "0" ["file_description"]=> NULL ["virtual"]=> string(1) "0" ["ymleasyimport_price_id"]=> NULL ["id_xmlimport"]=> NULL ["stock"]=> array(3) { [1]=> string(5) "0.000" [3]=> string(5) "0.000" [4]=> string(5) "0.000" } ["unconverted_currency"]=> string(3) "USD" ["currency"]=> string(3) "RUB" ["frontend_price"]=> float(169258) ["unconverted_price"]=> float(1781.6) ["frontend_compare_price"]=> float(0) ["unconverted_compare_price"]=> float(0) }
В корзину
Купить в 1 клик
Каталожный номер: 268091
Supply
Rated voltage19.2 ... 35 V DC
Rated current150 ... 100 mA
Power dissipation3 W
Ethernet Interface
Intrinsically safe port10 BASE-T/100 BASE-TX
Non-intrinsically safe port10 BASE-T/100 BASE-TX
Connection type2 x RJ-45 , IEC 60603-7
Connector pinoutsocket TIA/EIA-568-B
Transfer rate10/100 Mbit/s , Auto-Negotiation
Operating modeHalf/Full Duplex
Cable typeCAT5e S/FTP AWG 24, Installation cable, L/R ratio max. 10 µH/&Omega of all strand combinations
I.S. cable lengthtyp. 100 m/20 °C
Total cable lengthtyp. 200 m/20 °C
Number of isolatorsmax. 2 in series connection
Indicators/operating means
LED PWRgreen: Power on
LED ACTyellow: communication active
LED 10/100yellow ON: Transfer rate 100 MBit/s , OFF: 10 MBit/s
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013
Standard conformity
Galvanic isolationEN 50020
Degree of protectionIEC 60529
Climatic conditionsDIN IEC 721
Shock resistanceEN 60068-2-27
Vibration resistanceEN 60068-2-6
EthernetIEEE 802.3 , IEEE 802.3u
Ambient conditions
Ambient temperature-20 ... 55 °C (-4 ... 131 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Relative humidity&le 95 % non-condensing
Shock resistance15 g 11 ms
Vibration resistance1 g 10 ... 150 Hz
Pollution degreemax. 2, according to IEC 60664
Mechanical specifications
Connection typeTerminals
Core cross-sectionup to 2.5 mm2
Housing materialPolyamide PA 66
Degree of protectionIP20 according to EN 60529
Mass195 g
MountingDIN rail mounting
Data for application in connection with hazardous areas
EC-Type Examination CertificatePTB 07 ATEX 2025 X
Group, category, type of protection, temperature classEx-Hexagon II (1) GD [Ex ia] IIB , Ex-Hexagon II 3 (1GD) G Ex nA [ia IIB] II T4 , Ex-Hexagon I (M1) [Ex ia] I
Supply
Maximum safe voltage253 V AC
Directive conformity
Directive 2014/34/EUEN 60079-0:2012 , EN 60079-11:2012 , EN 60079-15:2010
Certificates and approvals
PatentsThis product may be covered by the following patent: US7,687,791
Узнать цену
Каталожный номер: T160404
Supply
Connectionbackplane LB9035A
Rated voltage24 V DC
Power consumptionmax. 39 W , available output power for Zone 2 applications 5 W (5V), 20 W (12V), else 5 W (5V), 35 W (12V)
Auxiliary energy24 V DC
Trunk load 10 mA according to FF standard.
Fieldbus interface
FOUNDATION Fieldbus
Connectionplug-in screw connector on the backplane
Baud rate31.25 kBit/s , MBP
ProtocolH1 to IEC 1158-2
Station connectiondirectly at the trunk or via spur protector
Number of stations per bus line1 or 2, depending on the required response times
Number of channels per stationmax. 20 analog, max. 40 digital
Bus lengthmax. 1900 m
(must not be exceeded by the sum of all trunk and spur lines)
Spur lengthmax. 120 m
(depending on the number of field devices. Modular I/O station = 1 field device)
Addressingvia PCS (software)
Indicators/settings
LED indicatorCom unit LB8110*:
LED green (power supply): on = operating, fast flash = cold start
LED red (collective alarm): on = internal fault, flashing = no fieldbus
LED yellow (operating mode): flashing = active
Power supply LB9006C:
LED green (power supply): off in case of loss of 24 V or 12 V or 5 V
I/O modules (refer to the table with compatible modules for order codes):
Power LED green: supply
Diagnostic LED red: module fault, red flashing: communication error
Status LED red: line fault
Status LED yellow: signal (Live Zero status)
Directive conformity
Electromagnetic compatibility
Directive 2004/108/ECEN 61326-1
Conformity
Degree of protectionIEC 60529
Ambient conditions
Ambient temperature-20 ... 60 °C (-4 ... 140 °F)
Mechanical specifications
Degree of protectionIP20
Dimensions275 x 127 mm (10.8 x 5 inch)
Data for application in connection with hazardous areas
Statement of conformityPF 08 CERT 1234 X
Group, category, type of protection, temperature classEx-Hexagon II 3 G Ex nA IIC T4
Directive conformity
Directive 94/9/ECEN 60079-0 , EN 60079-15
Узнать цену
Каталожный номер: T178361
General specifications
Design / MountingCabinet installation
Fieldbus interface
Fieldbus typeFOUNDATION Fieldbus
Physical layer profileprofile type 511 (FISCO), profile type 111 (Entity)
ITK version6.1.1
Implementationresource block 1x RS
function block 4x DO, 12x DI, 1x AI, 2x MDI, 1x MDO
transducer block 4x TB
FDE (Fault Disconnect Equipment)6.7 mA
Polaritynot polarity sensitive
Rated voltage9 ... 32 V
Rated currentmax. 23 mA
Indicators/operating means
LED PWRgreen: on, bus voltage existent
LED COM ERRred, continuous lightning: hardware error red, flashing: no bus activities or bus fault off: no error
LED CHANNEL ERRORred, flashing: lead breakage/short circuit off: no error
DIP switchAddress setting , write protection , simulation
Analog input
Number of inputs1
Input typeFrequency input / Counter Input , channel 1
Switching frequencymin. 0.1 Hz max. 5 kHz
Pulse durationmin. 80 µs
Supply voltage5 V
Supply current5 mA
Line fault detectionlead breakage , short circuit (not in counter mode)
Digital input
Number of inputs12
Input typeSensor input , channels 1, 4, 7, 10 multiplexed , cycle adjustable
Supply voltage6.6 V
Supply current5 mA
Line fault detectionlead breakage , short circuit
Input typeSensor input , channels 2, 3, 5, 6, 8, 9, 11, 12 multiplexed , cycle fixed
Supply voltage5 V
Supply current5 mA
Time delay before availability2 ms
Line fault detectionlead breakage , short circuit
Digital output
Number of outputs4
Output typeLow power valve , channels 1, 4, 7, 10
Supply voltage6.6 V
Supply current1.5 mA
Line fault detectionlead breakage , short circuit
Galvanic isolation
Foundation Fieldbus/Field circuitsafe galvanic isolation acc. to EN 60079-11, voltage peak value 375 V
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013
Low voltage
Directive 2014/35/EUEN 61010-1:2010
Standard conformity
Galvanic isolationEN 60079-11
Electromagnetic compatibilityNE 21:2011
Degree of protectionIEC/EN 60529
Fieldbus standardIEC 61158-2
Shock resistanceEN 60068-2-27
Vibration resistanceEN 60068-2-6
Ambient conditions
Ambient temperature-50 ... 75 °C (-58 ... 167 °F) hazardous area
-50 ... 85 °C (-58 ... 185 °F) safe area
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Relative humidity&le 95 % non-condensing
Shock resistance15 g , 11 ms
Vibration resistance5 g , 10 ... 150 Hz
Pollution degree2
Corrosion resistanceacc. to ISA-S71.04-1985, severity level G3
Mechanical specifications
Connection typeplug-in terminals , spring terminal and screw terminal
Core cross-section
Busup to 2.5 mm2
Inputsup to 2.5 mm2
Housing materialPolycarbonate
Degree of protectionIP20
Massapprox. 290 g
Mountingmounting on DIN rail in cabinet
Data for application in connection with hazardous areas
EU-Type Examination CertificateBVS 16 ATEX E 075 X
MarkingEx-Hexagon II 2 (1) G Ex ib [ia Ga] IIC T4 Gb , Ex-Hexagon II 3 (1) G Ex ic [ia Ga] IIC T4 Gc , Ex-Hexagon II 3 (1) G Ex ec [ia Ga] IIC T4 Gc , Ex-Hexagon I (M1) [Ex ia Ma] I , Ex-Hexagon II (1) D [Ex ia Da] IIIC
Field-side
Voltage Uo9 V
Current Io43 mA
Power Po96 mW
FOUNDATION Fieldbus
Maximum safe voltage Um253 V
Voltage Ui24 V
Current Ii380 mA
Power Pi5.32 W
Directive conformity
Directive 2014/34/EUEN 60079-0:2012 , EN 60079-11:2012 , EN 60079-7:2015
International approvals
IECEx approvalIECEx BVS 16.0051X
Approved forEx ib [ia Ga] IIC T4 Gb ,
Ex ic [ia Ga] IIC T4 Gc ,
Ex ec [ia Ga] IIC T4 Gc ,
[Ex ia Da] IIIC , [Ex ia Ma] I
Certificates and approvals
Marine approvalpending
Узнать цену
Каталожный номер: T179189
General specifications
Design / MountingCabinet installation
Fieldbus interface
Fieldbus typePROFIBUS PA
FDE (Fault Disconnect Equipment)6.7 mA
Polaritynot polarity sensitive
Rated voltage9 ... 32 V
Rated currentmax. 23 mA
Indicators/operating means
LED PWRgreen: on, bus voltage existent
LED COM ERRred, continuous lightning: hardware error red, flashing: no bus activities or bus fault off: no error
LED CHANNEL ERRORred, flashing: lead breakage/short circuit off: no error
DIP switchAddress setting , write protection , simulation
Analog input
Number of inputs1
Input typeFrequency input / Counter Input , channel 1
Switching frequencymin. 0.1 Hz max. 5 kHz
Pulse durationmin. 80 µs
Supply voltage5 V
Supply current5 mA
Line fault detectionlead breakage , short circuit (not in counter mode)
Digital input
Number of inputs12
Input typeSensor input , channels 1, 4, 7, 10 multiplexed , cycle adjustable
Supply voltage6.6 V
Supply current5 mA
Line fault detectionlead breakage , short circuit
Input typeSensor input , channels 2, 3, 5, 6, 8, 9, 11, 12 multiplexed , cycle fixed
Supply voltage5 V
Supply current5 mA
Time delay before availability2 ms
Line fault detectionlead breakage , short circuit
Digital output
Number of outputs4
Output typeLow power valve , channels 1, 4, 7, 10
Supply voltage6.6 V
Supply current1.5 mA
Line fault detectionlead breakage , short circuit
Galvanic isolation
Foundation Fieldbus/Field circuitsafe galvanic isolation acc. to EN 60079-11, voltage peak value 375 V
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013
Low voltage
Directive 2014/35/EUEN 61010-1:2010
Standard conformity
Galvanic isolationEN 60079-11
Electromagnetic compatibilityNE 21:2011
Degree of protectionIEC/EN 60529
Fieldbus standardIEC 61158-2
Shock resistanceEN 60068-2-27
Vibration resistanceEN 60068-2-6
Ambient conditions
Ambient temperature-50 ... 75 °C (-58 ... 167 °F) hazardous area
-50 ... 85 °C (-58 ... 185 °F) safe area
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Relative humidity&le 95 % non-condensing
Shock resistance15 g , 11 ms
Vibration resistance5 g , 10 ... 150 Hz
Pollution degree2
Corrosion resistanceacc. to ISA-S71.04-1985, severity level G3
Mechanical specifications
Connection typeplug-in terminals , spring terminal and screw terminal
Core cross-section
Busup to 2.5 mm2
Inputsup to 2.5 mm2
Housing materialPolycarbonate
Degree of protectionIP20
Massapprox. 290 g
Mountingmounting on DIN rail in cabinet
Data for application in connection with hazardous areas
EU-Type Examination CertificateBVS 16 ATEX E 075 X
MarkingEx-Hexagon II 2 (1) G Ex ib [ia Ga] IIC T4 Gb , Ex-Hexagon II 3 (1) G Ex ic [ia Ga] IIC T4 Gc , Ex-Hexagon II 3 (1) G Ex ec [ia Ga] IIC T4 Gc , Ex-Hexagon I (M1) [Ex ia Ma] I , Ex-Hexagon II (1) D [Ex ia Da] IIIC
PROFIBUS PA
Maximum safe voltage Um253 V
Voltage Ui24 V
Current Ii380 mA
Power Pi5.32 W
Field-side
Voltage Uo9 V
Current Io43 mA
Power Po96 mW
Directive conformity
Directive 2014/34/EUEN 60079-0:2012 , EN 60079-11:2012 , EN 60079-7:2015
International approvals
IECEx approvalIECEx BVS 16.0051X
Approved forEx ib [ia Ga] IIC T4 Gb ,
Ex ic [ia Ga] IIC T4 Gc ,
Ex ec [ia Ga] IIC T4 Gc ,
[Ex ia Da] IIIC , [Ex ia Ma] I
Certificates and approvals
Marine approvalpending
Узнать цену
Каталожный номер: T179190
General specifications
Design / MountingOutside installation
Electronic componentBinary multi-input/output R8D0-MIO-Ex12.FF* For technical data on installed electronic component see data sheet.
Fieldbus interface
Fieldbus typeFOUNDATION Fieldbus
Galvanic isolation
Foundation Fieldbus/Field circuitsafe galvanic isolation acc. to EN 60079-11, voltage peak value 375 V
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013
Low voltage
Directive 2014/35/EUEN 61010-1:2010
Standard conformity
Galvanic isolationEN 60079-11
Electromagnetic compatibilityNE 21:2011
Degree of protectionIEC 60529
Fieldbus standardIEC 61158-2
Shock resistanceEN 60068-2-27
Vibration resistanceEN 60068-2-6
Ambient conditions
Ambient temperature-40 ... 70 °C (-40 ... 158 °F) hazardous area
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Relative humidity&le 95 % non-condensing
Shock resistance15 g , 11 ms
Vibration resistance10 g , 10 ... 150 Hz
Corrosion resistanceacc. to ISA-S71.04-1985, severity level G3
Mechanical specifications
Connection typeplug-in terminals , spring terminal and screw terminal
Core cross-section
Busup to 2.5 mm2
Inputsup to 2.5 mm2
Cable diametersee table 2
Cable glandsensor inputs M16, fieldbus M20
Housing materialEN 1780-1 46000 , ISO AlSi9Cu3(Fe) , anodized
Degree of protectionIP66
Mass1800 g
Mountingpanel mounting
Data for application in connection with hazardous areas
EU-Type Examination CertificateBVS 16 ATEX E 075 X
MarkingEx-Hexagon II 2 (1) G Ex ib [ia Ga] IIC T4 Gb , Ex-Hexagon II 3 (1) G Ex ic [ia Ga] IIC T4 Gc , Ex-Hexagon II 3 (1) G Ex ec [ia Ga] IIC T4 Gc , Ex-Hexagon I (M1) [Ex ia Ma] I , Ex-Hexagon II (1) D [Ex ia Da] IIIC , Ex-Hexagon II 2 (1) D Ex tb [ia Da] IIIC T130 °C Db
BusFISCO see EC-Type Examination Certificate
Directive conformity
Directive 2014/34/EUEN 60079-0:2012 , EN 60079-7:2015 , EN 60079-11:2012 , EN 60079-31:2014
International approvals
IECEx approvalIECEx BVS 16.0051X
Approved forEx ib [ia Ga] IIC T4 Gb , Ex ic [ia Ga] IIC T4 Gc , Ex ec [ia Ga] IIC T4 Gc , [Ex ia Ma] I , [Ex ia Da] IIIC , Ex tb [ia Da] IIIC T130 °C Db
Certificates and approvals
Marine approvalpending
Узнать цену
Каталожный номер: T179186
General specifications
Design / MountingOutside installation
Electronic componentBinary multi-input/output R8D0-MIO-Ex12.PA* For technical data on installed electronic component see data sheet.
Fieldbus interface
Fieldbus typePROFIBUS PA
Galvanic isolation
Foundation Fieldbus/Field circuitsafe galvanic isolation acc. to EN 60079-11, voltage peak value 375 V
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013
Low voltage
Directive 2014/35/EUEN 61010-1:2010
Standard conformity
Galvanic isolationEN 60079-11
Electromagnetic compatibilityNE 21:2011
Degree of protectionIEC 60529
Fieldbus standardIEC 61158-2
Shock resistanceEN 60068-2-27
Vibration resistanceEN 60068-2-6
Ambient conditions
Ambient temperature-40 ... 70 °C (-40 ... 158 °F) hazardous area
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Relative humidity&le 95 % non-condensing
Shock resistance15 g , 11 ms
Vibration resistance10 g , 10 ... 150 Hz
Corrosion resistanceacc. to ISA-S71.04-1985, severity level G3
Mechanical specifications
Connection typeplug-in terminals , spring terminal and screw terminal
Core cross-section
Busup to 2.5 mm2
Inputsup to 2.5 mm2
Cable diametersee table 2
Cable glandsensor inputs M16, fieldbus M20
Housing materialEN 1780-1 46000 , ISO AlSi9Cu3(Fe) , anodized
Degree of protectionIP66
Mass1800 g
Mountingpanel mounting
Data for application in connection with hazardous areas
EU-Type Examination CertificateBVS 16 ATEX E 075 X
MarkingEx-Hexagon II 2 (1) G Ex ib [ia Ga] IIC T4 Gb , Ex-Hexagon II 3 (1) G Ex ic [ia Ga] IIC T4 Gc , Ex-Hexagon II 3 (1) G Ex ec [ia Ga] IIC T4 Gc , Ex-Hexagon I (M1) [Ex ia Ma] I , Ex-Hexagon II (1) D [Ex ia Da] IIIC , Ex-Hexagon II 2 (1) D Ex tb [ia Da] IIIC T130 °C Db
BusFISCO see EC-Type Examination Certificate
Directive conformity
Directive 2014/34/EUEN 60079-0:2012 , EN 60079-7:2015 , EN 60079-11:2012 , EN 60079-31:2014
International approvals
IECEx approvalIECEx BVS 16.0051X
Approved forEx ib [ia Ga] IIC T4 Gb , Ex ic [ia Ga] IIC T4 Gc , Ex ec [ia Ga] IIC T4 Gc , [Ex ia Ma] I , [Ex ia Da] IIIC , Ex tb [ia Da] IIIC T130 °C Db
Certificates and approvals
Marine approvalpending
Узнать цену
Каталожный номер: T179391
General specifications
Design / MountingOutside installation
Installed componentsBinary multi-input/output R8D0-MIO-Ex12.FF* , For technical data on installed electronic component see data sheet.
Fieldbus interface
Fieldbus typeFOUNDATION Fieldbus
Conformity
Degree of protectionEN 60529
Ambient conditions
Ambient temperature-30 ... 55 °C (-22 ... 131 °F) , (extended temperature range available on request)
Storage temperature-40 ... 70 °C (-40 ... 158 °F)
Relative humidity< 75 % (annual mean)
< 95 % (30 d/year), no moisture condensation
Mechanical specifications
Degree of protectionIP66
Dimensions(W x H x D)
271 x 271 x 136 mm
Mountingthru-holes Ø6.5 mm
Data for application in connection with hazardous areas
EU-Type Examination CertificatePTB 07 ATEX 1061 (assembled Junction Box) , for additional certificates see www.pepperl-fuchs.com
CertificatePF 16 CERT 4011 (assembled Junction Box) , for additional certificates see www.pepperl-fuchs.com
MarkingEx-Hexagon II 3(1)G Ex ic [ia Ga] IIC T4 Gc
Ex-Hexagon II 3(1)G Ex ec [ia Ga] IIC T4 Gc
Ex-Hexagon II 3(1)D Ex tc [ia Da] IIIC T135°C Dc
Directive conformity
Directive 2014/34/EUEN 60079-0:2012 , EN 60079-7:2015 , EN 60079-11:2012 , EN 60079-31:2014
International approvals
IECEx approvalIECEx PTB 07.0036 , Zone 1 , suitable Junction Box on request
IECEx PTB 09.0016 , Zone 2 , suitable Junction Box on request
INMETROTÜV 13.1143
Узнать цену
Каталожный номер: T179392
General specifications
Design / MountingOutside installation
Installed componentsBinary multi-input/output R8D0-MIO-Ex12.PA* , For technical data on installed electronic component see data sheet.
Fieldbus interface
Fieldbus typePROFIBUS PA
Conformity
Degree of protectionEN 60529
Ambient conditions
Ambient temperature-30 ... 55 °C (-22 ... 131 °F) , (extended temperature range available on request)
Storage temperature-40 ... 70 °C (-40 ... 158 °F)
Relative humidity< 75 % (annual mean)
< 95 % (30 d/year), no moisture condensation
Mechanical specifications
Degree of protectionIP66
Dimensions(W x H x D)
271 x 271 x 136 mm
Mountingthru-holes Ø6.5 mm
Data for application in connection with hazardous areas
EU-Type Examination CertificatePTB 07 ATEX 1061 (assembled Junction Box) , for additional certificates see www.pepperl-fuchs.com
CertificatePF 16 CERT 4011 (assembled Junction Box) , for additional certificates see www.pepperl-fuchs.com
MarkingEx-Hexagon II 3(1)G Ex ic [ia Ga] IIC T4 Gc
Ex-Hexagon II 3(1)G Ex ec [ia Ga] IIC T4 Gc
Ex-Hexagon II 3(1)D Ex tc [ia Da] IIIC T135°C Dc
Directive conformity
Directive 2014/34/EUEN 60079-0:2012 , EN 60079-7:2015 , EN 60079-11:2012 , EN 60079-31:2014
International approvals
IECEx approvalIECEx PTB 07.0036 , Zone 1 , suitable Junction Box on request
IECEx PTB 09.0016 , Zone 2 , suitable Junction Box on request
INMETROTÜV 13.1143
Узнать цену
Каталожный номер: T180801
General specifications
Design / MountingOutside installation
Installed componentsBinary multi-input/output R8D0-MIO-Ex12.FF* , For technical data on installed electronic component see data sheet.
Fieldbus interface
Fieldbus typeFOUNDATION Fieldbus
Conformity
Degree of protectionEN 60529
Ambient conditions
Ambient temperature-30 ... 55 °C (-22 ... 131 °F) , (extended temperature range available on request)
Storage temperature-40 ... 70 °C (-40 ... 158 °F)
Relative humidity< 75 % (annual mean)
< 95 % (30 d/year), no moisture condensation
Mechanical specifications
Degree of protectionIP66
Dimensions(W x H x D)
300 x 230 x 132 mm
Mountingthru-holes Ø10 mm
Data for application in connection with hazardous areas
EU-Type Examination CertificatePTB 07 ATEX 1061 (assembled Junction Box) , for additional certificates see www.pepperl-fuchs.com
CertificatePF 16 CERT 4011 (assembled Junction Box) , for additional certificates see www.pepperl-fuchs.com
MarkingEx-Hexagon II 3(1)G Ex ic [ia Ga] IIC T4 Gc
Ex-Hexagon II 3(1)G Ex ec [ia Ga] IIC T4 Gc
Ex-Hexagon II 3(1)D Ex tc [ia Da] IIIC T135°C Dc
Directive conformity
Directive 2014/34/EUEN 60079-0:2012 , EN 60079-7:2015 , EN 60079-11:2012 , EN 60079-31:2014
International approvals
IECEx approvalIECEx PTB 07.0036 , Zone 1 , suitable Junction Box on request
IECEx PTB 09.0016 , Zone 2 , suitable Junction Box on request
INMETROTÜV 13.1143
Узнать цену
Каталожный номер: T180802
General specifications
Design / MountingOutside installation
Installed componentsBinary multi-input/output R8D0-MIO-Ex12.PA* , For technical data on installed electronic component see data sheet.
Fieldbus interface
Fieldbus typePROFIBUS PA
Conformity
Degree of protectionEN 60529
Ambient conditions
Ambient temperature-30 ... 55 °C (-22 ... 131 °F) , (extended temperature range available on request)
Storage temperature-40 ... 70 °C (-40 ... 158 °F)
Relative humidity< 75 % (annual mean)
< 95 % (30 d/year), no moisture condensation
Mechanical specifications
Degree of protectionIP66
Dimensions(W x H x D)
300 x 230 x 132 mm
Mountingthru-holes Ø10 mm
Data for application in connection with hazardous areas
EU-Type Examination CertificatePTB 07 ATEX 1061 (assembled Junction Box) , for additional certificates see www.pepperl-fuchs.com
CertificatePF 16 CERT 4011 (assembled Junction Box) , for additional certificates see www.pepperl-fuchs.com
MarkingEx-Hexagon II 3(1)G Ex ic [ia Ga] IIC T4 Gc
Ex-Hexagon II 3(1)G Ex ec [ia Ga] IIC T4 Gc
Ex-Hexagon II 3(1)D Ex tc [ia Da] IIIC T135°C Dc
Directive conformity
Directive 2014/34/EUEN 60079-0:2012 , EN 60079-7:2015 , EN 60079-11:2012 , EN 60079-31:2014
International approvals
IECEx approvalIECEx PTB 07.0036 , Zone 1 , suitable Junction Box on request
IECEx PTB 09.0016 , Zone 2 , suitable Junction Box on request
INMETROTÜV 13.1143
Узнать цену
Каталожный номер: T158061
General specifications
Design / MountingCabinet installation
Fieldbus interface
Fieldbus typeFOUNDATION Fieldbus
Physical layer profileprofile type 511 (FISCO), profile type 111 (Entity)
ITK version4.51
Implementationresource block1x RS
function block8x AI, 1x MAI
transducer block8x sensor TB, 1x concentrator TB
Execution timeAI, MAI 40 ms max.
Macro cycletypical for one device 8xAI or 1xMAI max. 500 ms
Firmware updatevia separate plug connection
FDE (Fault Disconnect Equipment)6.7 mA
Polaritynot polarity sensitive
Rated voltage9 ... 32 V
Rated currentmax. 23 mA
Indicators/operating means
LED PWRgreen: on, bus voltage existent
LED COM ERRred: continuous lightning: hardware error 2 Hz flashing: no bus activities or bus fault off: no error
LED CHANNEL ERRORred: 2 Hz flashing: lead breakage, overrange off: no error
Input
Number8
Sensor typessee table 1
Groundinggrounding of thermoelements possible
Error detectionlead breakage, wiring error, hardware device error
Common mode voltageInput to Input 600 Vpeak
Transfer characteristics
Deviation
Influence of ambient temperaturesee table 3
LinearizationT/C input 0.1°C RTD input 0.03°C
Internal measurement cyclefor all sensor types max. 1 s
Galvanic isolation
Fieldbus/inputssafe galvanic isolation acc. to EN 60079-11, voltage peak value 375 V
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013
Standard conformity
Galvanic isolationEN 60079-11
Electromagnetic compatibilityNE 21:2011
Degree of protectionIEC 60529
Fieldbus standardIEC 61158-2
Shock resistanceEN 60068-2-27
Vibration resistanceEN 60068-2-6
Ambient conditions
Ambient temperature-40 ... 70 °C (-40 ... 158 °F) hazardous area
-40 ... 85 °C (-40 ... 185 °F) safe area
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Relative humidity&le 95 % non-condensing
Shock resistance15 g , 11 ms
Vibration resistance5 g , 10 ... 150 Hz
Corrosion resistanceacc. to ISA-S71.04-1985, severity level G3
Mechanical specifications
Connection typeplug-in terminals , spring terminal and screw terminal
Core cross-section
Busup to 2.5 mm2
Inputsup to 2.5 mm2
Housing materialPolycarbonate
Degree of protectionIP20
Mass360 g
Mountingmounting on DIN rail in cabinet
Data for application in connection with hazardous areas
EC-Type Examination CertificatePTB 03 ATEX 2237
Group, category, type of protection, temperature classEx-Hexagon II 2 (1) G Ex ia [ia Ga] IIC T4 Gb , Ex-Hexagon II (1) G [Ex ia Ga] IIC , Ex-Hexagon II (1) D [Ex ia Da] IIIC , Ex-Hexagon II 3 G Ex ic IIC T4 Gc
BusFISCO see EC-Type Examination Certificate
Inputssee EC-Type Examination Certificate
Statement of conformityPTB 03 ATEX 2238 X
Group, category, type of protection, temperature classEx-Hexagon II 3 G Ex nA IIC T4 Gc
Galvanic isolation
Bussee Statement of Conformity
Inputsee EC-Type Examination Certificate
Directive conformity
Directive 2014/34/EUEN 60079-0:2012 , EN 60079-11:2012 , EN 60079-15:2010
International approvals
IECEx approvalIECEx PTB 05.0001 , IECEx PTB 05.0002X
Approved forEx ia [ia Ga] IIC T4 Gb , [Ex ia Ga] IIC , [Ex ia Da] IIIC , Ex ic IIC T4 Gc , Ex nA IIC T4 Gc
Certificates and approvals
Marine approvalDNV A-14038
Узнать цену
Каталожный номер: T163902
General specifications
Design / MountingCabinet installation
Fieldbus interface
Fieldbus typePROFIBUS PA
Firmware updatevia separate plug connection
FDE (Fault Disconnect Equipment)6.7 mA
Polaritynot polarity sensitive
Rated voltage9 ... 32 V
Rated currentmax. 23 mA
PROFIBUS PA
Profile3.02
Indicators/operating means
LED PWRgreen: on, bus voltage existent
LED COM ERRred, continuous lightning: hardware error red, flashing: no bus activities or bus fault off: no error
LED CHANNEL ERRORred: 2 Hz flashing: lead breakage, overrange off: no error
Input
Number8
Sensor typessee table 1
Groundinggrounding of thermoelements possible
Error detectionlead breakage, wiring error, hardware device error
Common mode voltageInput to Input 600 Vpeak
Transfer characteristics
Deviation
Influence of ambient temperaturesee table 3
LinearizationT/C input 0.1°C RTD input 0.03°C
Internal measurement cyclefor all sensor types max. 1 s
Galvanic isolation
Fieldbus/inputssafe galvanic isolation acc. to EN 60079-11, voltage peak value 375 V
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013
Standard conformity
Galvanic isolationEN 60079-11
Electromagnetic compatibilityNE 21:2011
Degree of protectionIEC 60529
Fieldbus standardIEC 61158-2
Shock resistanceEN 60068-2-27
Vibration resistanceEN 60068-2-6
Ambient conditions
Ambient temperature-40 ... 70 °C (-40 ... 158 °F) hazardous area
-40 ... 85 °C (-40 ... 185 °F) safe area
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Relative humidity&le 95 % non-condensing
Shock resistance15 g , 11 ms
Vibration resistance5 g , 10 ... 150 Hz
Corrosion resistanceacc. to ISA-S71.04-1985, severity level G3
Mechanical specifications
Connection typeplug-in terminals , spring terminal and screw terminal
Core cross-section
Busup to 2.5 mm2
Inputsup to 2.5 mm2
Housing materialPolycarbonate
Degree of protectionIP20
Mass360 g
Mountingmounting on DIN rail in cabinet
Data for application in connection with hazardous areas
EU-Type Examination CertificatePTB 03 ATEX 2237
MarkingEx-Hexagon II 2 (1) G Ex ia [ia Ga] IIC T4 Gb , Ex-Hexagon II (1) G [Ex ia Ga] IIC , Ex-Hexagon II (1) D [Ex ia Da] IIIC , Ex-Hexagon II 3 G Ex ic IIC T4 Gc
BusFISCO see EC-Type Examination Certificate
Voltage Ui24 V
Inputssee EC-Type Examination Certificate
CertificatePTB 03 ATEX 2238 X
MarkingEx-Hexagon II 3 G Ex nA IIC T4 Gc
Galvanic isolation
Bussee Statement of Conformity
Inputsee EC-Type Examination Certificate
Directive conformity
Directive 2014/34/EUEN 60079-0:2012 , EN 60079-11:2012 , EN 60079-15:2010
International approvals
FM approvalCoC 3025732
CSA approvalCoC 3025732C
IECEx approvalIECEx PTB 05.0001 , IECEx PTB 05.0002X
Approved forEx ia [ia Ga] IIC T4 Gb , [Ex ia Ga] IIC , [Ex ia Da] IIIC , Ex ic IIC T4 Gc , Ex nA IIC T4 Gc
Certificates and approvals
Marine approvalDNV A-14038
Узнать цену
Каталожный номер: T158062
General specifications
Design / MountingOutside installation
Electronic componentTemperature Multi-Input Device RD0-TI-Ex8.FF* For technical data on installed electronic component see data sheet.
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013
Standard conformity
Galvanic isolationEN 60079-11
Electromagnetic compatibilityNE 21:2011
Degree of protectionIEC 60529
Fieldbus standardIEC 61158-2
Shock resistanceEN 60068-2-27
Vibration resistanceEN 60068-2-6
Ambient conditions
Ambient temperaturesee table 1
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Relative humidity&le 95 % non-condensing
Shock resistance15 g , 11 ms
Vibration resistance10 g , 10 ... 150 Hz
Corrosion resistanceacc. to ISA-S71.04-1985, severity level G3
Mechanical specifications
Connection typeplug-in terminals , spring terminal and screw terminal
Core cross-section
Busup to 2.5 mm2
Inputsup to 2.5 mm2
Cable diametersee table 2
Cable glandsensor inputs M16, fieldbus M20
Housing materialEN 1780-1 46000 , ISO AlSi9Cu3(Fe) , anodized
Degree of protectionIP67
Mass1800 g
Mountingpanel mounting
Data for application in connection with hazardous areas
EU-Type Examination CertificatePTB 03 ATEX 2237
MarkingEx-Hexagon II 2 (1) G Ex ia [ia Ga] IIC T4 Gb , Ex-Hexagon II (1) G [Ex ia Ga] IIC , Ex-Hexagon II (1) D [Ex ia Da] IIIC , Ex-Hexagon II 3 G Ex ic IIC T4 Gc
BusFISCO see EC-Type Examination Certificate
Inputssee EC-Type Examination Certificate
CertificatePTB 03 ATEX 2238 X
MarkingEx-Hexagon II 3 G Ex nA IIC T4 Gc
Galvanic isolation
Bussee Statement of Conformity
Inputsee EC-Type Examination Certificate
Directive conformity
Directive 2014/34/EUEN 60079-0:2012 , EN 60079-11:2012 , EN 60079-15:2010
International approvals
IECEx approvalIECEx PTB 05.0001 , IECEx PTB 05.0002X
Approved forEx ia [ia Ga] IIC T4 Gb , [Ex ia Ga] IIC , [Ex ia Da] IIIC , Ex ic IIC T4 Gc , Ex nA IIC T4 Gc
Certificates and approvals
Marine approvalDNV A-14038
Узнать цену
Каталожный номер: T165021
General specifications
Design / MountingOutside installation
Electronic componentTemperature Multi-Input Device RD0-TI-Ex8.PA* For technical data on installed electronic component see data sheet.
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013
Standard conformity
Galvanic isolationEN 60079-11
Electromagnetic compatibilityNE 21:2011
Degree of protectionIEC 60529
Fieldbus standardIEC 61158-2
Shock resistanceEN 60068-2-27
Vibration resistanceEN 60068-2-6
Ambient conditions
Ambient temperaturesee table 1
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Relative humidity&le 95 % non-condensing
Shock resistance15 g , 11 ms
Vibration resistance10 g , 10 ... 150 Hz
Corrosion resistanceacc. to ISA-S71.04-1985, severity level G3
Mechanical specifications
Connection typeplug-in terminals , spring terminal and screw terminal
Core cross-section
Busup to 2.5 mm2
Inputsup to 2.5 mm2
Cable diametersee table 2
Cable glandsensor inputs M16, fieldbus M20
Housing materialEN 1780-1 46000 , ISO AlSi9Cu3(Fe) , anodized
Degree of protectionIP66
Mass1800 g
Mountingpanel mounting
Data for application in connection with hazardous areas
EU-Type Examination CertificatePTB 03 ATEX 2237
MarkingEx-Hexagon II 2 (1) G Ex ia [ia Ga] IIC T4 Gb , Ex-Hexagon II (1) G [Ex ia Ga] IIC , Ex-Hexagon II (1) D [Ex ia Da] IIIC , Ex-Hexagon II 3 G Ex ic IIC T4 Gc
BusFISCO see EC-Type Examination Certificate
Voltage Ui24 V
Inputssee EC-Type Examination Certificate
CertificatePTB 03 ATEX 2238 X
MarkingEx-Hexagon II 3 G Ex nA IIC T4 Gc
Galvanic isolation
Bussee Statement of Conformity
Inputsee EC-Type Examination Certificate
Directive conformity
Directive 2014/34/EUEN 60079-0:2012 , EN 60079-11:2012 , EN 60079-15:2010
International approvals
FM approvalCoC 3025732
CSA approvalCoC 3025732C
IECEx approvalIECEx PTB 05.0001 , IECEx PTB 05.0002X
Approved forEx ia [ia Ga] IIC T4 Gb , [Ex ia Ga] IIC , [Ex ia Da] IIIC , Ex ic IIC T4 Gc , Ex nA IIC T4 Gc
Certificates and approvals
Marine approvalDNV A-14038
Узнать цену
Каталожный номер: T47957
General specifications
Design / MountingOutside installation
Installed componentsTemperature Multi-Input Device RD0-TI-Ex8.FF.ST
For technical data on installed electronic component see data sheet.
Conformity
Degree of protectionEN 60529
Ambient conditions
Ambient temperature-30 ... 55 °C (-22 ... 131 °F) , (extended temperature range available on request)
Storage temperature-40 ... 70 °C (-40 ... 158 °F)
Relative humidity< 75 % (annual mean)
< 95 % (30 d/year), no moisture condensation
Mechanical specifications
Degree of protectionIP66
Dimensions(W x H x D)
271 x 271 x 136 mm (1 x RD0-TI-Ex8.FF.ST)
Mountingthru-holes Ø6.5 mm
Data for application in connection with hazardous areas
EU-Type Examination CertificatePTB 07 ATEX 1061 (assembled Junction Box) , for additional certificates see www.pepperl-fuchs.com
CertificatePF 16 CERT 3134 X (assembled Junction Box) , for additional certificates see www.pepperl-fuchs.com
MarkingEx-Hexagon II 3G Ex ic IIC T4 Gc
Ex-Hexagon II 3G Ex nA IIC T4 Gc
Ex-Hexagon II 3D Ex tc IIIC T135°C Dc
Directive conformity
Directive 2014/34/EUEN 60079-0:2012 , EN 60079-11:2012 , EN 60079-15:2010 , EN 60079-31:2014
International approvals
IECEx approvalIECEx PTB 07.0036 , Zone 1 , suitable Junction Box on request
IECEx PTB 09.0016 , Zone 2 , suitable Junction Box on request
INMETROTÜV 13.1143
Узнать цену
Каталожный номер: T166122
General specifications
Design / MountingOutside installation
Installed componentsTemperature Multi-Input Device RD0-TI-Ex8.PA.ST
For technical data on installed electronic component see data sheet.
Conformity
Degree of protectionEN 60529
Ambient conditions
Ambient temperature-30 ... 55 °C (-22 ... 131 °F) , (extended temperature range available on request)
Storage temperature-40 ... 70 °C (-40 ... 158 °F)
Relative humidity< 75 % (annual mean)
< 95 % (30 d/year), no moisture condensation
Mechanical specifications
Degree of protectionIP66
Dimensions(W x H x D)
271 x 271 x 136 mm (1 x RD0-TI-Ex8.FF.ST)
Mountingthru-holes Ø6.5 mm
Data for application in connection with hazardous areas
EU-Type Examination CertificatePTB 07 ATEX 1061 (assembled Junction Box) , for additional certificates see www.pepperl-fuchs.com
CertificatePF 16 CERT 3134 X (assembled Junction Box) , for additional certificates see www.pepperl-fuchs.com
MarkingEx-Hexagon II 3G Ex ic IIC T4 Gc
Ex-Hexagon II 3G Ex nA IIC T4 Gc
Ex-Hexagon II 3D Ex tc IIIC T135°C Dc
Directive conformity
Directive 2014/34/EUEN 60079-0:2012 , EN 60079-11:2012 , EN 60079-15:2010 , EN 60079-31:2014
International approvals
IECEx approvalIECEx PTB 07.0036 , Zone 1 , suitable Junction Box on request
IECEx PTB 09.0016 , Zone 2 , suitable Junction Box on request
INMETROTÜV 13.1143
Узнать цену
Каталожный номер: T47956
General specifications
Design / MountingOutside installation
Installed componentsTemperature Multi-Input Device RD0-TI-Ex8.FF.ST
For technical data on installed electronic component see data sheet.
Conformity
Degree of protectionEN 60529
Ambient conditions
Ambient temperature-30 ... 55 °C (-22 ... 131 °F) , (extended temperature range available on request)
Storage temperature-40 ... 70 °C (-40 ... 158 °F)
Relative humidity< 75 % (annual mean)
< 95 % (30 d/year), no moisture condensation
Mechanical specifications
Degree of protectionIP66
Dimensions(W x H x D)
300 x 200 x 120 mm (1 x RD0-TI-Ex8.FF.ST)
Mountingthru-holes Ø10 mm
Data for application in connection with hazardous areas
EU-Type Examination CertificatePTB 07 ATEX 1061 (assembled Junction Box) , for additional certificates see www.pepperl-fuchs.com
CertificatePF 16 CERT 3134 X (assembled Junction Box) , for additional certificates see www.pepperl-fuchs.com
MarkingEx-Hexagon II 3G Ex ic IIC T4 Gc
Ex-Hexagon II 3G Ex nA IIC T4 Gc
Ex-Hexagon II 3D Ex tc IIIC T135°C Dc
Directive conformity
Directive 2014/34/EUEN 60079-0:2012 , EN 60079-11:2012 , EN 60079-15:2010 , EN 60079-31:2014
International approvals
IECEx approvalIECEx PTB 07.0036 , Zone 1 , suitable Junction Box on request
IECEx PTB 09.0016 , Zone 2 , suitable Junction Box on request
INMETROTÜV 13.1143
Узнать цену
Каталожный номер: T166121
General specifications
Design / MountingOutside installation
Installed componentsTemperature Multi-Input Device RD0-TI-Ex8.PA.ST
For technical data on installed electronic component see data sheet.
Conformity
Degree of protectionEN 60529
Ambient conditions
Ambient temperature-30 ... 55 °C (-22 ... 131 °F) , (extended temperature range available on request)
Storage temperature-40 ... 70 °C (-40 ... 158 °F)
Relative humidity< 75 % (annual mean)
< 95 % (30 d/year), no moisture condensation
Mechanical specifications
Degree of protectionIP66
Dimensions(W x H x D)
300 x 200 x 120 mm (1 x RD0-TI-Ex8.FF.ST)
Mountingthru-holes Ø10 mm
Data for application in connection with hazardous areas
EU-Type Examination CertificatePTB 07 ATEX 1061 (assembled Junction Box) , for additional certificates see www.pepperl-fuchs.com
CertificatePF 16 CERT 3134 X (assembled Junction Box) , for additional certificates see www.pepperl-fuchs.com
MarkingEx-Hexagon II 3G Ex ic IIC T4 Gc
Ex-Hexagon II 3G Ex nA IIC T4 Gc
Ex-Hexagon II 3D Ex tc IIIC T135°C Dc
Directive conformity
Directive 2014/34/EUEN 60079-0:2012 , EN 60079-11:2012 , EN 60079-15:2010 , EN 60079-31:2014
International approvals
IECEx approvalIECEx PTB 07.0036 , Zone 1 , suitable Junction Box on request
IECEx PTB 09.0016 , Zone 2 , suitable Junction Box on request
INMETROTÜV 13.1143
Узнать цену
Каталожный номер: T47955
General specifications
Design / MountingOutside installation
Installed componentsValve Coupler FD0-VC-Ex4.**
For technical data on installed electronic component see data sheet.
Conformity
Degree of protectionEN 60529
Ambient conditions
Ambient temperature-20 ... 55 °C (-4 ... 131 °F) , (extended temperature range available on request)
Storage temperature-40 ... 70 °C (-40 ... 158 °F)
Relative humidity< 75 % (annual mean)
< 95 % (30 d/year), no moisture condensation
Mechanical specifications
Degree of protectionIP66
Dimensions(W x H x D)
271 x 544 x 136 mm (1 x FD0-VC-Ex4.**)
Mountingthru-holes Ø6.5 mm
Data for application in connection with hazardous areas
EU-Type Examination CertificatePTB 07 ATEX 1061 (assembled Junction Box) , for additional certificates see www.pepperl-fuchs.com
Directive conformity
Directive 2014/34/EUEN 60079-0:2012 , EN 60079-11:2012
International approvals
IECEx approvalIECEx PTB 07.0036 , suitable Junction Box on request
INMETROTÜV 13.1143
Узнать цену
Каталожный номер: T47955
General specifications
Design / MountingOutside installation
Installed componentsValve Coupler FD0-VC-Ex4.**
For technical data on installed electronic component see data sheet.
Conformity
Degree of protectionEN 60529
Ambient conditions
Ambient temperature-20 ... 55 °C (-4 ... 131 °F) , (extended temperature range available on request)
Storage temperature-40 ... 70 °C (-40 ... 158 °F)
Relative humidity< 75 % (annual mean)
< 95 % (30 d/year), no moisture condensation
Mechanical specifications
Degree of protectionIP66
Dimensions(W x H x D)
271 x 544 x 136 mm (1 x FD0-VC-Ex4.**)
Mountingthru-holes Ø6.5 mm
Data for application in connection with hazardous areas
EU-Type Examination CertificatePTB 07 ATEX 1061 (assembled Junction Box) , for additional certificates see www.pepperl-fuchs.com
Directive conformity
Directive 2014/34/EUEN 60079-0:2012 , EN 60079-11:2012
International approvals
IECEx approvalIECEx PTB 07.0036 , suitable Junction Box on request
INMETROTÜV 13.1143
Узнать цену
Каталожный номер: T47954
General specifications
Design / MountingOutside installation
Installed componentsValve Coupler FD0-VC-Ex4.**
For technical data on installed electronic component see data sheet.
Conformity
Degree of protectionEN 60529
Ambient conditions
Ambient temperature-20 ... 55 °C (-4 ... 131 °F) , (extended temperature range available on request)
Storage temperature-40 ... 70 °C (-40 ... 158 °F)
Relative humidity< 75 % (annual mean)
< 95 % (30 d/year), no moisture condensation
Mechanical specifications
Degree of protectionIP66
Dimensions(W x H x D)
380 x 380 x 175 mm (1 x FD0-VC-Ex4.**)
Mountingthru-holes Ø10 mm
Data for application in connection with hazardous areas
EU-Type Examination CertificatePTB 07 ATEX 1061 (assembled Junction Box) , for additional certificates see www.pepperl-fuchs.com
Directive conformity
Directive 2014/34/EUEN 60079-0:2012 , EN 60079-11:2012
International approvals
IECEx approvalIECEx PTB 07.0036 , suitable Junction Box on request
INMETROTÜV 13.1143
Узнать цену
Каталожный номер: T47954
General specifications
Design / MountingOutside installation
Installed componentsValve Coupler FD0-VC-Ex4.**
For technical data on installed electronic component see data sheet.
Conformity
Degree of protectionEN 60529
Ambient conditions
Ambient temperature-20 ... 55 °C (-4 ... 131 °F) , (extended temperature range available on request)
Storage temperature-40 ... 70 °C (-40 ... 158 °F)
Relative humidity< 75 % (annual mean)
< 95 % (30 d/year), no moisture condensation
Mechanical specifications
Degree of protectionIP66
Dimensions(W x H x D)
380 x 380 x 175 mm (1 x FD0-VC-Ex4.**)
Mountingthru-holes Ø10 mm
Data for application in connection with hazardous areas
EU-Type Examination CertificatePTB 07 ATEX 1061 (assembled Junction Box) , for additional certificates see www.pepperl-fuchs.com
Directive conformity
Directive 2014/34/EUEN 60079-0:2012 , EN 60079-11:2012
International approvals
IECEx approvalIECEx PTB 07.0036 , suitable Junction Box on request
INMETROTÜV 13.1143
Узнать цену
Каталожный номер: T42294
Supply
Connectionbackplane bus
Rated voltage5 V DC , only in connection with the power supplies FB92**
Power consumption2 W
Auxiliary energy24 V DC
Trunk load 20 mA
Fieldbus interface
Fieldbus typeFOUNDATION Fieldbus H1
FOUNDATION Fieldbus
Connectionwired to Ex e terminals via backplane
Baud rate31.25 kBit/s , MBP
ProtocolH1 to IEC 1158-2
Station connectiondirectly at the trunk or via spur protector
Number of stations per bus line1 or 2, depending on the required response times
Number of channels per stationmax. 20 analog, max. 40 digital
Supported I/O modules5 slots, to be filled with (combinations possible):
1*08 digital input, 8-channel, NAMUR
3*05 analog input, 4-channel, 20 mA (HART via service bus)
4*05 analog output, 4-channel, 20 mA (HART via service bus)
5204 Pt100 RTD input, 4-channel
5205 thermocouple input, 4-channel
6305 relay output, 4-channel, 230 V
6306 relay output, 8-channel, 24 V
6*08 digital output, 8-channel, Ex i
6210-6215 digital output, 4-channel, Ex i power
* = variable (2=IS, 3=Ex e)
Bus lengthmax. 1900 m
(must not be exceeded by the sum of all trunk and spur lines)
Spur lengthmax. 120 m
(depending on the number of field devices. Modular I/O station = 1 field device)
Addressingvia PCS (software)
Internal bus
Connectionbackplane bus
Indicators/settings
LED indicatorLED green (power supply): On = operating, fast flash = cold start
LED red (collective alarm): On = internal fault, flashing = no fieldbus
LED yellow (operating mode): Flashing = active
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1
Conformity
Electromagnetic compatibilityNE 21
Degree of protectionIEC 60529
Ambient conditions
Ambient temperature-20 ... 60 °C (-4 ... 140 °F)
Storage temperature-25 ... 85 °C (-13 ... 185 °F)
Relative humidity95 % non-condensing
Shock resistanceshock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18
Vibration resistancefrequency range 10 ... 150 Hz transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g 10 cycles
frequency range 5 ... 100 Hz transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g 90 minutes at each resonance
Damaging gasdesigned for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3
Mechanical specifications
Degree of protectionIP20 (module) , a separate housing is required acc. to the system description
Connectionvia backplane
Massapprox. 750 g
Dimensions57 x 107 x 132 mm (2.2 x 4.2 x 5.2 inch)
Data for application in connection with hazardous areas
EU-Type Examination CertificatePTB 97 ATEX 1074 U
MarkingEx-Hexagon II 2 G Ex d IIC Gb
Directive conformity
Directive 2014/34/EUEN 60079-0:2009
EN 60079-1:2007
EN 60079-11:2007
EN 60079-26:2007
EN 61241-11:2006
International approvals
ATEX approvalPTB 97 ATEX 1075

EAC approvalRussia: RU C-IT.MIII06.B.00129
Marine approval
Lloyd Register15/20021
DNV GL MarineTAA0000034
American Bureau of ShippingT1450280/UN
Bureau Veritas Marine22449/B0 BV
Узнать цену
Каталожный номер: T159196
Supply
Connectionbackplane bus
Rated voltage5 V DC , only in connection with the power supplies LB9***
Power consumption2 W
Auxiliary energy24 V DC
Trunk load 20 mA
Fieldbus interface
Fieldbus typeFOUNDATION Fieldbus H1
FOUNDATION Fieldbus
Connectionplug-in screw connector on the backplane
Baud rate31.25 kBit/s , MBP
ProtocolH1 to IEC 1158-2
Station connectiondirectly at the trunk or via spur protector
Number of stations per bus line1 or 2, depending on the required response times
Number of channels per stationmax. 20 analog, max. 40 digital
Supported I/O modules5 slots, to be filled with (combinations possible):
1*08 digital input, 8-channel, NAMUR
3*05 analog input, 4-channel, 20 mA (HART via service bus)
4*05 analog output, 4-channel, 20 mA (HART via service bus)
5*04 Pt100 RTD input, 4-channel
5*05 thermocouple input, 4-channel
6005 relay output, 4-channel, 230 V
6006 relay output, 8-channel, 24 V
6*08 digital output, 8-channel, Ex i
6*10-6*15 digital output, 4-channel, Ex i power
* = variable (0=non-IS, 1=IS)
Bus lengthmax. 1900 m
(must not be exceeded by the sum of all trunk and spur lines)
Spur lengthmax. 120 m
(depending on the number of field devices. Modular I/O station = 1 field device)
Addressingvia PCS (software)
Internal bus
Connectionbackplane bus
Indicators/settings
LED indicatorLED 1 (power supply): On = operating, fast flash = cold start
LED 2 (collective alarm): On = internal fault, flashing = no fieldbus
LED 3 (operating mode): Flashing = active
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1
Conformity
Electromagnetic compatibilityNE 21
Degree of protectionIEC 60529
Ambient conditions
Ambient temperature-20 ... 60 °C (-4 ... 140 °F)
Storage temperature-25 ... 85 °C (-13 ... 185 °F)
Shock resistanceshock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18
Vibration resistancefrequency range 10 ... 150 Hz transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g 10 cycles
frequency range 5 ... 100 Hz transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g 90 minutes at each resonance
Damaging gasdesigned for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3
Mechanical specifications
Degree of protectionIP20 (module) , mounted on backplane
Connectionvia backplane
Massapprox. 150 g
Dimensions32.5 x 100 x 102 mm (1.28 x 3.9 x 4 inch)
Data for application in connection with hazardous areas
CertificatePF 08 CERT 1234 X
MarkingEx-Hexagon II 3 G Ex nA IIC T4 Gc
Directive conformity
Directive 2014/34/EUEN 60079-0:2009
EN 60079-11:2007
EN 60079-15:2010
International approvals
ATEX approvalPF 08 CERT 1234 X
UL approvalE106378
Control drawing116-0321
Approved forcUL (Canada): CL I Zn. 2 IIC IS circuits for CL I Zn. 0 IIC
ULus (USA): CL I Div. 2 Grp. A, B, C, D IS circuits for CL I, II, III Div. 1 Grp. A, B, C, D, E, F, G
IECEx approvalBVS 09.0037X
Approved forEx nA IIC T4 Gc
EAC approvalRussia: RU C-IT.MIII06.B.00129
Marine approval
Lloyd Register15-20021
DNV GL MarineTAA0000034
American Bureau of ShippingT1450280/UN
Узнать цену
Каталожный номер: T41360
Описание оборудования
Com Unit for MODBUS RTU
Узнать цену
Каталожный номер: 287613
Supply
Connectionbackplane bus
Rated voltage5 V DC , only in connection with the power supplies FB92**
Power consumption2 W
Fieldbus interface
Fieldbus typeMODBUS RTU
MODBUS RTU
Connectionwired to Ex e terminals via backplane
Baud ratemax. 38.4 kBit/s
Number of stations per bus linemax. 245 (MODBUS), max. 119 (service bus)
Number of channels per stationmax. 80 analog, max. 184 digital (standard configuration)
Number of stations per bus segmentmax. 31 (RS-485 standard)
Number of repeaters between Master and Slavemax. 3
Supported I/O modulesall FB remote I/O modules
Bus lengthmax. 1200 m (FOL, 38.4 kBd),
max. 1200 m (copper cable, 38.4 kBd)
FOL (fiber optic link)additional hardware required
Addressingvia configuration software
MODBUS addressstandard compliant
(factory standard setting: 126)
Service bus addressmax. 119 , redundancy address = base + 128 (automatic)
HART communicationvia service bus
Internal bus
Connectionbackplane bus
Redundancyvia front connector
Indicators/settings
LED indicatorLED green (power supply): On = operating, fast flash = cold start
LED red (collective alarm): On = internal fault, flashing = no Modbus RTU connection
LED yellow (operating mode): flashing 1 (1:1 ratio) = active, normal operation flashing 2 (7:1 ratio) = active, simulation
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1
Conformity
Electromagnetic compatibilityNE 21
Degree of protectionIEC 60529
Ambient conditions
Ambient temperature-20 ... 60 °C (-4 ... 140 °F)
Storage temperature-25 ... 85 °C (-13 ... 185 °F)
Relative humidity95 % non-condensing
Shock resistanceshock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18
Vibration resistancefrequency range 10 ... 150 Hz transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g 10 cycles
frequency range 5 ... 100 Hz transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g 90 minutes at each resonance
Damaging gasdesigned for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3
Mechanical specifications
Degree of protectionIP20 (module) , a separate housing is required acc. to the system description
Connectionvia backplane
Massapprox. 750 g
Dimensions57 x 107 x 132 mm (2.2 x 4.2 x 5.2 inch)
Data for application in connection with hazardous areas
EU-Type Examination CertificatePTB 97 ATEX 1074 U
MarkingEx-Hexagon II 2(1) G Ex d [ia Ga] IIC Gb
Directive conformity
Directive 2014/34/EUEN 60079-0:2009
EN 60079-1:2007
EN 60079-11:2007
EN 60079-26:2007
EN 61241-11:2006
International approvals
ATEX approvalPTB 97 ATEX 1075

EAC approvalRussia: RU C-IT.MIII06.B.00129
Marine approval
Lloyd Register15/20021
DNV GL MarineTAA0000034
American Bureau of ShippingT1450280/UN
Bureau Veritas Marine22449/B0 BV
Розничная цена
1698.3 $ с НДС 161344 с НДС
array(31) { ["id"]=> string(5) "95469" ["product_id"]=> string(6) "152099" ["id_1c"]=> NULL ["sku"]=> string(6) "287613" ["sort"]=> string(1) "0" ["name"]=> string(0) "" ["image_id"]=> NULL ["price"]=> float(161344) ["primary_price"]=> string(11) "1698.306944" ["purchase_price"]=> float(0) ["compare_price"]=> float(0) ["count"]=> string(5) "0.000" ["available"]=> string(1) "1" ["stock_base_ratio"]=> NULL ["order_count_min"]=> NULL ["order_count_step"]=> NULL ["status"]=> string(1) "1" ["dimension_id"]=> NULL ["file_name"]=> string(0) "" ["file_size"]=> string(1) "0" ["file_description"]=> NULL ["virtual"]=> string(1) "0" ["ymleasyimport_price_id"]=> NULL ["id_xmlimport"]=> NULL ["stock"]=> array(3) { [1]=> string(5) "0.000" [3]=> string(5) "0.000" [4]=> string(5) "0.000" } ["unconverted_currency"]=> string(3) "USD" ["currency"]=> string(3) "RUB" ["frontend_price"]=> float(161344) ["unconverted_price"]=> float(1698.3) ["frontend_compare_price"]=> float(0) ["unconverted_compare_price"]=> float(0) }
В корзину
Купить в 1 клик
Добавлено в корзину!

Товаров: 0

На сумму: 0

Продолжить покупки
Оформить заказ

Клиенты

Блог

Подписка

Последнее на форуме

ООО "Зипстор"
127282, RU, Московская область, Москва, ул. Полярная, 33, стр. 3
+7 (800) 551-66-17
info@zipstore.ru