Атол 30Ф не включается (заводской брак)
Валерий
14 января 2022
Описание оборудования | ||
---|---|---|
Field Unit, Polyester (GRP) |
Описание оборудования | ||
---|---|---|
Field Unit, Polyester (GRP) |
Описание оборудования | ||
---|---|---|
Field Unit, Polyester (GRP) |
Описание оборудования | ||
---|---|---|
Field Unit, Polyester (GRP) |
Описание оборудования | ||
---|---|---|
Field Unit, Stainless Steel |
Описание оборудования | ||
---|---|---|
Field Unit, Stainless Steel |
Описание оборудования | ||
---|---|---|
Field Unit, Polyester (GRP) |
General specifications | ||
---|---|---|
Installed components | backplane LB9023A | |
Slots | ||
Bus coupler | 1 | |
Supply | 1 | |
I/O modules (single width) | max. 8 | |
I/O modules (dual width) | max. 4 | |
Supply | ||
Connection | screw terminals, max. 10 mm2 | |
Rated voltage | 24 V DC | |
Maximum safe voltage | 60 V | |
Fieldbus interface | ||
Fieldbus type | PROFIBUS DP/DP-V1 or MODBUS RTU , depends on bus coupler | |
Electrical specifications | ||
Permissible power | wall mounting: 43 W (at 40 °C (104 °F)) , 21.5 W (at 50 °C (122 °F)) | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2006 | |
Conformity | ||
Degree of protection | EN 60529 | |
Ambient conditions | ||
Ambient temperature | -20 ... 55 °C (-4 ... 131 °F) at T4 , depending on the permissible power | |
Storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
Mechanical specifications | ||
Degree of protection | IP66, NEMA 4X | |
Mass | approx. 10 kg , without modules | |
Dimensions | (W x H x D) 350 x 306 x 215 mm (13.8 x 12 x 8.5 inch) | |
Mounting | thru-holes Ø11 mm | |
Data for application in connection with hazardous areas | ||
Statement of conformity | PF 08 CERT 1267 | |
Group, category, type of protection | ![]() ![]() ![]() ![]() ![]() ![]() | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2009 EN 60079-11:2007 EN 60079-15:2005 EN 61241-0:2006 EN 61241-1:2004 EN 61241-11:2006 EN 61010-1:2001 |
Описание оборудования | ||
---|---|---|
Redundancy Field Unit, Polyester (GRP) |
Описание оборудования | ||
---|---|---|
Redundancy Field Unit, Polyester (GRP) |
Описание оборудования | ||
---|---|---|
Redundancy Field Unit, Polyester (GRP) |
Описание оборудования | ||
---|---|---|
Redundancy Field Unit, Polyester (GRP) |
Описание оборудования | ||
---|---|---|
Redundancy Field Unit, Stainless Steel |
Описание оборудования | ||
---|---|---|
Redundancy Field Unit, Polyester (GRP) |
Описание оборудования | ||
---|---|---|
Redundancy Field Unit, Stainless Steel |
Описание оборудования | ||
---|---|---|
Redundancy Field Unit, Stainless Steel |
Supply | ||
---|---|---|
Rated voltage | see datasheets of float switches | |
Electrical specifications | ||
Contact loading | see datasheets of float switches | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | see datasheets of float switches | |
Low voltage | ||
Directive 2014/35/EU | see datasheets of float switches | |
Conformity | ||
Degree of protection | IEC 60529:2001 | |
Application | ||
Description | switching element: LFL1: floating up closing, normally open LFL2: microswitch with switching ball, change-over contact LFL3: mercury (Hg) change-over contact | |
Operating conditions | ||
Installation conditions | ||
Installation instructions | range of application and minimum length between mounting and float: - PVC version: &ge 50 mm (2 inch), preferred for water - PUR version: &ge 100 mm (4 inch), preferred for fuels, heating oils, oily fluids - CSM/CM version: &ge 100 mm (4 inch), preferred for many acids and lyes Float switches are fastened onto the lower end of the guide pipe in the factory. The position of the switch points required for the application must be adjusted by the user by moving the set collars (in some cases, it may be necessary to shorten the float switch wire). | |
Process conditions | ||
Process pressure (static pressure) | &le 1 bar at 20 °C (68 °F) | |
Ambient conditions | ||
Ambient temperature | 5 ... 70 °C (41 ... 158 °F) | |
Storage temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Mechanical specifications | ||
Degree of protection | Float Switch : IP68 terminal box: IP66 | |
Mechanical construction | ||
Dimensions | guide tube: &empty16 mm (0.6 inch), Lmax = 3000 mm (10 feet) | |
Material | float: PP (Polypropylene) guide tube: PVC process connection: PVC set collars and clamping screw: PVC |
Supply | ||
---|---|---|
Rated voltage | 8.2 V ± 2 V | |
Current consumption | < 1.0 mA unswitched (de-energized at the bottom), > 2.2 mA switched (floated up at the top) | |
Reverse polarity protection | yes | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 60947-5-2:2007+A1:2012 | |
Conformity | ||
Degree of protection | IEC 60529:2001 | |
Application | ||
Description | Proximity switch with operation ball | |
Function and system design | ||
Equipment architecture | A measuring system consists of a float switch LFL1-**-N and a transformer isolated barrier, e. g. KFD2-SR2-Ex1.W. | |
Operating conditions | ||
Installation conditions | ||
Installation instructions | range of application and minimum length between mounting and float: - PVC version: &ge 50 mm (2 inch), preferred for water - PUR version: &ge 100 mm (4 inch), preferred for fuels, heating oils, oily fluids - CSM/CM version: &ge 100 mm (4 inch), preferred for many acids and lyes mounting: - The float switch is mounted either from sidewards through a cable gland &ge G1A into the vessel or - by means of a counter weight or rods (e. g. float switch combination) from the top. The pivot of the cable should always be horizontal. | |
Process conditions | ||
Process pressure (static pressure) | sleeve design: &le 3 bar at 20 °C (68 °F) ball design: &le 2 bar at 20 °C (68 °F) | |
Density | sleeve design: &ge 0.8 g/cm3 ball design: &ge 0.6 g/cm3 | |
Ambient conditions | ||
Ambient temperature | -20 ... 70 °C (-4 ... 158 °F) | |
Storage temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Altitude | &le 2000 m above MSL | |
Mechanical specifications | ||
Degree of protection | IP68 | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | TÜV 99 ATEX 1407 | |
Group, category, type of protection | ![]() | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 | |
Mechanical construction | ||
Material | float: PP (Polypropylene) cable: - PVC version: PVC cable, highly flexible (2 x 0.75 mm2) - PUR version: PUR cable, highly flexible (2 x 0.50 mm2) - CSM/CM version: CSM/CM cable (chlorinated polyethylene, (2 x 0.75 mm2)) |
Electrical specifications | ||
---|---|---|
Contact loading | 250 V AC/3 A 150 V DC/0.25 A resistive load 60 V DC/1 A resistive load | |
Rated insulation voltage | 300 V | |
Pulse withstand voltage | 4 kV | |
Directive conformity | ||
Low voltage | ||
Directive 2014/35/EU | EN 60947-5-1:2004 + Cor.:2005 + A1:2009 | |
Conformity | ||
Degree of protection | IEC 60529:2001 | |
Application | ||
Description | microswitch with switching ball, change-over contact | |
Function and system design | ||
Equipment architecture | This device may be used with any sequential circuit, as long as the circuit can support the electrical circuit values of the switching elements. | |
Operating conditions | ||
Installation conditions | ||
Installation instructions | range of application and minimum length between mounting and float: - PVC version: &ge 50 mm (2 inch), preferred for water - PUR version: &ge 100 mm (4 inch), preferred for fuels, heating oils, oily fluids - CSM/CM version: &ge 100 mm (4 inch), preferred for many acids and lyes mounting: - The float switch is mounted either from sidewards through a cable gland &ge G1A into the vessel or - by means of a counter weight or rods (e. g. float switch combination) from the top. The pivot of the cable should always be horizontal. | |
Process conditions | ||
Process pressure (static pressure) | sleeve design: &le 3 bar at 20 °C (68 °F) ball design: &le 2 bar at 20 °C (68 °F) | |
Density | sleeve design: &ge 0.8 g/cm3 ball design: &ge 0.6 g/cm3 | |
Ambient conditions | ||
Ambient temperature | PVC version: 5 ... 70 °C (41 ... 158 °F) PUR version: 5 ... 70 °C (41 ... 158 °F) CSM/CM version: -20 ... 70 °C (-4 ... 158 °F) | |
Storage temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Altitude | &le 2000 m above MSL | |
Mechanical specifications | ||
Degree of protection | IP68 | |
Mechanical construction | ||
Material | float: PP (Polypropylene) cable: - PVC version: PVC cable, highly flexible (3 x 0.75 mm2) - PUR version: PUR cable, highly flexible (3 x 0.50 mm2) - CSM/CM version: CSM/CM cable (chlorinated polyethylene, (3 x 0.75 mm2)) |
Electrical specifications | ||
---|---|---|
Contact loading | 230 V AC/3 A/200 VA 150 V DC/3 A/100 W resistive load | |
Rated insulation voltage | 300 V | |
Pulse withstand voltage | 4 kV | |
Directive conformity | ||
Low voltage | ||
Directive 2014/35/EU | EN 60947-5-1:2004 + Cor.:2005 + A1:2009 | |
Conformity | ||
Degree of protection | IEC 60529:2001 | |
Application | ||
Description | mercury (Hg) change-over contact | |
Function and system design | ||
Equipment architecture | This device may be used with any sequential circuit, as long as the circuit can support the electrical circuit values of the switching elements. | |
Operating conditions | ||
Installation conditions | ||
Installation instructions | range of application and minimum length between mounting and float: - PVC version: &ge 50 mm (2 inch), preferred for water - PUR version: &ge 100 mm (4 inch), preferred for fuels, heating oils, oily fluids - CSM/CM version: &ge 100 mm (4 inch), preferred for many acids and lyes - TPK version: &ge 100 mm (4 inch), preferred for many acids and lyes mounting: - The float switch is mounted either from sidewards through a cable gland &ge G1A into the vessel or - by means of a counter weight or rods (e. g. float switch combination) from the top. The pivot of the cable should always be horizontal. | |
Process conditions | ||
Process pressure (static pressure) | sleeve design: &le 3 bar at 20 °C (68 °F) ball design: &le 2 bar at 20 °C (68 °F) | |
Density | sleeve design: &ge 0.8 g/cm3 ball design: &ge 0.6 g/cm3 | |
Ambient conditions | ||
Ambient temperature | PVC version: 5 ... 70 °C (41 ... 158 °F) PUR version: 5 ... 70 °C (41 ... 158 °F) CSM/CM version: -20 ... 70 °C (-4 ... 158 °F) TPK version: 5 ... 70 °C (41 ... 158 °F) | |
Storage temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Altitude | &le 2000 m above MSL | |
Mechanical specifications | ||
Degree of protection | IP68 | |
Mechanical construction | ||
Material | float: PP (Polypropylene) cable: - PVC version: PVC cable, highly flexible (3 x 0.75 mm2) - PUR version: PUR cable, highly flexible (3 x 0.50 mm2) - CSM/CM version: CSM/CM cable (chlorinated polyethylene, (3 x 0.75 mm2)) - TPK version: TPK cable, (3 x 0.75 mm2) |
Описание оборудования | ||
---|---|---|
Base station NON-Ex |
Описание оборудования | ||
---|---|---|
Base station |
Описание оборудования | ||
---|---|---|
Charger |
Описание оборудования | ||
---|---|---|
Div. 2 / Zone 2 Ex-rated barrier |
Описание оборудования | ||
---|---|---|
Div. 2 Non-incendive barrier |
Описание оборудования | ||
---|---|---|
Div. 2 Non-incendive barrier |
Conformity | ||
---|---|---|
Degree of protection | IEC 60529 | |
Ambient conditions | ||
Ambient temperature | -20 ... 50 °C (-4 ... 122 °F) | |
Storage temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Mechanical specifications | ||
Degree of protection | IP66 | |
Connection | 1 cable gland M16 x 1.5 for cable diameter 5,5 ... 10 mm, blue color 1 M12 x 5 connector for connecting a barcode reader type PSCAN-D 1 PE bolt M6 | |
Material | Housing: antistatic glass reinforced polyester, black color Holder for barcode reader: stainless steel 1.4301 (304) M12 cable gland: stainless steel 1.4301 (304) PE bolt: brass | |
Mass | approx. 2000 g | |
Dimensions | 155 x 145 x 217 mm | |
Data for application in connection with hazardous areas | ||
Statement of conformity | ||
Group, category, type of protection, temperature class | ![]() | |
Voltage | 30 V | |
Current | 500 mA | |
Power | 2 W | |
General information | ||
Supplementary information | Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
General specifications | ||
---|---|---|
Type | Power supply | |
Supply | ||
Rated voltage | 24 V DC -10 %, +20 %, absolute Maximum +32 V DC | |
Electrical specifications | ||
Current consumption | 1 feed circuit : app. 380mA continuous current 2 feed circuits : app. 550mA continuous current 3 feed circuits : app. 720mA continuous current | |
Interface | ||
Interface type | Supply voltage: 2 x 2-pin connector, integrated jack/pin contacts Data interface: 9-pin SubD integrated jack, pin contacts, 20 mA CL active/passive, zero potential RS232 | |
Ambient conditions | ||
Operating temperature | 0 ... 50 °C (32 ... 122 °F) | |
Storage temperature | -20 ... 70 °C (-4 ... 158 °F) | |
Relative humidity | max. 85 % non-condensing (48 h endurance test) | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Mass | approx. 1 kg | |
Dimensions | 68.2 mm x 108 mm x 168 mm (W x H x D) | |
Data for application in connection with hazardous areas | ||
Statement of conformity | DMT 03 ATEX E 011X | |
Group, category, type of protection, temperature class | ![]() |
Описание оборудования | ||
---|---|---|
Handheld barcode reader |
Описание оборудования | ||
---|---|---|
Handheld barcode reader for use in harsh industrial conditions |
Товаров: 0
На сумму: 0