Атол 30Ф не включается (заводской брак)
Валерий
14 января 2022
General specifications | ||
---|---|---|
Signal type | Digital Input | |
Supply | ||
Connection | Power Rail or terminals 23+, 24- | |
Rated voltage | 20 ... 30 V DC | |
Rated current | approx. 100 mA | |
Power consumption | 1.8 W | |
Input | ||
Connection side | field side | |
Connection | Input I: terminals 1+, 3- input II: terminals 13+, 14- | |
Input I | acc. to EN 60947-5-6 (NAMUR), see system description for electrical data | |
Open circuit voltage/short-circuit current | 8.2 V / 10 mA | |
Switching point/switching hysteresis | 1.2 ... 2.1 mA / approx. 0.2 mA | |
Pulse duration | min. 75 µs / 1 ms see instruction manuals the maximum input frequency has to be observed. | |
Input frequency | 0 ... 80 Hz , pulse divider 0 ... 1 kHz | |
Line fault detection | breakage I &le 0.15 mA short-circuit I > 6.5 mA | |
Input II | reset | |
Active/Passive | I > 4 mA/I < 1.5 mA | |
Open circuit voltage/short-circuit current | 18 V / 5 mA | |
Pulse duration | min. 10 ms | |
Output | ||
Connection side | control side | |
Connection | output I: terminals 10, 11, 12 output II: terminals 19+, 20- | |
Output I | signal , Relay output | |
Contact loading | 253 V AC/ 2 A / cos &phi &ge 0.7 40 V DC/ 2 A | |
Mechanical life | 5 x 107 switching cycles | |
Energized/De-energized delay | approx. 20 ms / approx. 20 ms | |
Output II | signal , electronic unit, isolated | |
Contact loading | 40 V / 50 mA | |
Energized/De-energized delay | after rising input flank 3 ms after falling input flank 2 ms | |
Signal level | 1-signal: (L+) -2.5 V (50 mA, short-circuit/overload proof) 0-signal: blocked output (off-state current &le 10 µA) | |
Indicators/settings | ||
Display elements | LEDs , display | |
Control elements | Control panel | |
Configuration | via operating buttons | |
Labeling | space for labeling at the front | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Low voltage | ||
Directive 2014/35/EU | EN 61010-1:2010 | |
Conformity | ||
Electromagnetic compatibility | NE 21:2006 | |
Degree of protection | IEC 60529:2001 | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Connection | screw terminals | |
Mass | approx. 300 g | |
Dimensions | 40 x 119 x 115 mm (1.6 x 4.7 x 4.5 inch) , housing type C3 | |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | TÜV 99 ATEX 1408 | |
Marking | ![]() ![]() ![]() | |
Certificate | TÜV 02 ATEX 1885 X | |
Marking | ![]() | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010 | |
International approvals | ||
FM approval | ||
Control drawing | 116-0305 | |
UL approval | E223772 | |
IECEx approval | IECEx TUN 03.0000 | |
Approved for | [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I |
Описание оборудования | ||
---|---|---|
current limit 45 mA |
Описание оборудования | ||
---|---|---|
current limit 45 mA |
General specifications | ||
---|---|---|
Signal type | Digital Output | |
Functional safety related parameters | ||
Safety Integrity Level (SIL) | SIL 3 | |
Supply | ||
Connection | terminals 5+, 6- loop powered Power Rail or terminals 9+, 10- bus powered | |
Rated voltage | 19 ... 30 V DC | |
Input current | 75 mA at 24 V, 220 &Omega load | |
Power dissipation | 1.4 W at 24 V, 220 &Omega load | |
Input | ||
Connection side | control side | |
Connection | terminals 5+, 6- | |
Signal level | loop powered 1-signal: 19 ... 30 V DC 0-signal: 0 ... 5 V DC bus powered 1-signal: 15 ... 30 V DC (current limited at 5 mA) 0-signal: 0 ... 5 V DC | |
Rated current | 0-signal: typ. 1.6 mA at 1.5 V typ. 8 mA at 3 V (maximum leakage current DO card) 1-signal: &ge 36 mA (minmum load current DO card) | |
Output | ||
Connection side | field side | |
Connection | terminals 1+, 2- | |
Internal resistor | 285 &Omega | |
Current | typ. 45 mA | |
Voltage | typ. 10 V | |
Current limit | 45 mA | |
Open loop voltage | typ. 24.6 V | |
Load | nominal 0.05 ... 18 k&Omega | |
Output II | fault signal | |
Connection | terminals 7, 8 , non-intrinsically safe | |
Contact loading | 30 V DC/ 0.5 A resistive load | |
Mechanical life | 105 switching cycles | |
Energized/De-energized delay | &le 20 ms / &le 20 ms | |
Line fault detection | signal at short-circuit RB < 25 &Omega, lead breakage RB > 50 k&Omega test current < 500 µA | |
Galvanic isolation | ||
Output/Other circuits | basic insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff | |
Indicators/settings | ||
Display elements | LEDs | |
Control elements | DIP-switch | |
Configuration | via DIP switches | |
Labeling | space for labeling at the front | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Conformity | ||
Electromagnetic compatibility | NE 21:2012 , EN 61326-3-2:2008 For further information see system description. | |
Degree of protection | IEC 60529:2013 | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Connection | screw terminals | |
Mass | approx. 150 g | |
Dimensions | 12.5 x 114 x 119 mm (0.5 x 4.5 x 4.7 inch) , housing type A2 | |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | EXA 17 ATEX 0002 X | |
Marking | ![]() ![]() ![]() | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-7:2015 , EN 60079-11:2012 , EN 60079-15:2010 | |
International approvals | ||
IECEx approval | IECEx EXA 17.0001X | |
Approved for | Ex nC ec [ia Ga] IIC T4 Gc , [Ex ia Da] IIIC , [Ex ia Ma] I |
General specifications | ||
---|---|---|
Signal type | Digital Output | |
Functional safety related parameters | ||
Safety Integrity Level (SIL) | SIL 3 | |
Supply | ||
Connection | terminals 5+, 6- loop powered Power Rail or terminals 9+, 10- bus powered | |
Rated voltage | 19 ... 30 V DC | |
Input current | 80 mA at 24 V | |
Power dissipation | 1.3 W at 24 V | |
Load | 150 &Omega | |
Input | ||
Connection side | control side | |
Connection | terminals 5+, 6- | |
Signal level | loop powered 1-signal: 19 ... 30 V DC 0-signal: 0 ... 5 V DC bus powered 1-signal: 15 ... 30 V DC (current limited at 5 mA) 0-signal: 0 ... 5 V DC | |
Rated current | 0-signal: typ. 1.6 mA at 1.5 V typ. 8 mA at 3 V (maximum leakage current DO card) 1-signal: &ge 36 mA (minmum load current DO card) | |
Output | ||
Connection side | field side | |
Connection | terminals 1+, 2- | |
Internal resistor | 80 &Omega | |
Current | typ. 65 mA | |
Voltage | typ. 10 V | |
Current limit | 65 mA | |
Open loop voltage | typ. 16.4 V | |
Load | nominal 0.05 ... 18 k&Omega | |
Output II | fault signal | |
Connection | terminals 7, 8 , non-intrinsically safe | |
Contact loading | 30 V DC/ 0.5 A resistive load | |
Mechanical life | 105 switching cycles | |
Energized/De-energized delay | &le 20 ms / &le 20 ms | |
Line fault detection | signal at short-circuit RB < 25 &Omega, lead breakage RB > 50 k&Omega test current < 500 µA | |
Galvanic isolation | ||
Output/Other circuits | basic insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff | |
Indicators/settings | ||
Display elements | LEDs | |
Control elements | DIP-switch | |
Configuration | via DIP switches | |
Labeling | space for labeling at the front | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Conformity | ||
Electromagnetic compatibility | NE 21:2012 , EN 61326-3-2:2008 For further information see system description. | |
Degree of protection | IEC 60529:2013 | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Connection | screw terminals | |
Mass | approx. 150 g | |
Dimensions | 12.5 x 114 x 119 mm (0.5 x 4.5 x 4.7 inch) , housing type A2 | |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | EXA 17 ATEX 0002 X | |
Marking | ![]() ![]() ![]() | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-7:2015 , EN 60079-11:2012 , EN 60079-15:2010 | |
International approvals | ||
IECEx approval | IECEx EXA 17.0001X | |
Approved for | Ex nC ec [ia Ga] IIC T4 Gc , [Ex ia Da] IIIC , [Ex ia Ma] I |
General specifications | ||
---|---|---|
Signal type | Digital Output | |
Functional safety related parameters | ||
Safety Integrity Level (SIL) | SIL 3 | |
Supply | ||
Connection | terminals 5+, 6- loop powered Power Rail or terminals 9+, 10- bus powered | |
Rated voltage | 19 ... 30 V DC | |
Input current | 75 mA at 24 V , 270 &Omega load | |
Power dissipation | 1.3 W at 24 V , 270 &Omega load | |
Input | ||
Connection side | control side | |
Connection | terminals 5+, 6- | |
Signal level | loop powered 1-signal: 19 ... 30 V DC 0-signal: 0 ... 5 V DC bus powered 1-signal: 15 ... 30 V DC (current limited at 5 mA) 0-signal: 0 ... 5 V DC | |
Rated current | 0-signal: typ. 1.6 mA at 1.5 V typ. 8 mA at 3 V (maximum leakage current DO card) 1-signal: &ge 36 mA (minmum load current DO card) | |
Output | ||
Connection side | field side | |
Connection | terminals 1+, 2- | |
Internal resistor | 240 &Omega | |
Current | typ. 45 mA | |
Voltage | typ. 12 V | |
Current limit | 50 mA | |
Open loop voltage | typ. 24.6 V | |
Load | nominal 0.05 ... 18 k&Omega | |
Output II | fault signal | |
Connection | terminals 7, 8 , non-intrinsically safe | |
Contact loading | 30 V DC/ 0.5 A resistive load | |
Mechanical life | 105 switching cycles | |
Energized/De-energized delay | &le 20 ms / &le 20 ms | |
Line fault detection | signal at short-circuit RB < 25 &Omega, lead breakage RB > 50 k&Omega test current < 500 µA | |
Galvanic isolation | ||
Output/Other circuits | basic insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff | |
Indicators/settings | ||
Display elements | LEDs | |
Control elements | DIP-switch | |
Configuration | via DIP switches | |
Labeling | space for labeling at the front | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Conformity | ||
Electromagnetic compatibility | NE 21:2012 , EN 61326-3-2:2008 For further information see system description. | |
Degree of protection | IEC 60529:2013 | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Connection | screw terminals | |
Mass | approx. 150 g | |
Dimensions | 12.5 x 114 x 119 mm (0.5 x 4.5 x 4.7 inch) , housing type A2 | |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | EXA 17 ATEX 0002 X | |
Marking | ![]() ![]() ![]() | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-7:2015 , EN 60079-11:2012 , EN 60079-15:2010 | |
International approvals | ||
IECEx approval | IECEx EXA 17.0001X | |
Approved for | Ex nC ec [ia Ga] IIC T4 Gc , [Ex ia Da] IIIC , [Ex ia Ma] I |
Описание оборудования | ||
---|---|---|
current limit: 100 mA |
Описание оборудования | ||
---|---|---|
current limit 45 mA |
Описание оборудования | ||
---|---|---|
current limit 65 mA |
Описание оборудования | ||
---|---|---|
current limit 80 mA |
Описание оборудования | ||
---|---|---|
current limit 45 mA |
Описание оборудования | ||
---|---|---|
current limit 45 mA |
Описание оборудования | ||
---|---|---|
Lead monitoring |
Описание оборудования | ||
---|---|---|
Lead monitoring |
Описание оборудования | ||
---|---|---|
without lead monitoring |
General specifications | ||
---|---|---|
Signal type | Digital Output | |
Functional safety related parameters | ||
Safety Integrity Level (SIL) | SIL 2 | |
Supply | ||
Connection | Power Rail or terminals 14+, 15- | |
Rated voltage | 19 ... 30 V DC | |
Power dissipation | max. 1.5 W | |
Power consumption | max. 2 W at 45 mA output current | |
Input | ||
Connection side | control side | |
Connection | terminals 7, 8 | |
Input current | approx. 3 mA | |
Signal level | 1-signal: 16 ... 30 V DC 0-signal: 0 ... 5 V DC | |
Output | ||
Connection side | field side | |
Output I | ||
Connection | terminals 1+, 2- or 3- | |
Internal resistor | 270 &Omega | |
Current | max. 45 mA | |
Voltage | min. 11.2 V | |
Open loop voltage | min. 23.5 V | |
Output signal | These values are valid for the rated operating voltage 19 ... 30 V DC. | |
Energized/De-energized delay | &le 20 ms / &le 20 ms | |
Line fault detection | signal at short-circuit RB < 50 &Omega, lead breakage RB > 10 k&Omega test current < 650 µA | |
Output II | fault signal | |
Connection | terminals 10, 11, 12 , non-intrinsically safe | |
Contact loading | 253 V AC/2 A/cos &phi > 0.7 40 V DC/2 A resistive load | |
Mechanical life | 2 x 107 switching cycles | |
Energized/De-energized delay | &le 20 ms / &le 20 ms | |
Indicators/settings | ||
Display elements | LEDs | |
Control elements | DIP-switch | |
Configuration | via DIP switches | |
Labeling | space for labeling at the front | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Low voltage | ||
Directive 2014/35/EU | EN 61010-1:2010 | |
Conformity | ||
Electromagnetic compatibility | NE 21:2007 | |
Degree of protection | IEC 60529:2001 | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Connection | screw terminals | |
Mass | approx. 150 g | |
Dimensions | 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) , housing type B2 | |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | ZELM 99 ATEX 0015 | |
Marking | ![]() ![]() ![]() | |
Certificate | TÜV 02 ATEX 1820 X | |
Marking | ![]() | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010 , EN 60079-26:2007 , EN 50303:2000 | |
International approvals | ||
CSA approval | ||
Control drawing | 116-0362 | |
IECEx approval | IECEx ZLM 14.0001 | |
Approved for | [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I |
General specifications | ||
---|---|---|
Signal type | Digital Output | |
Functional safety related parameters | ||
Safety Integrity Level (SIL) | SIL 2 | |
Supply | ||
Connection | Power Rail or terminals 14+, 15- | |
Rated voltage | 19 ... 30 V DC | |
Power dissipation | max. 1.5 W | |
Power consumption | max. 2 W at 45 mA output current | |
Input | ||
Connection side | control side | |
Connection | terminals 7, 8 | |
Input current | 1-signal: 3.5 mA over the entire range 0-signal: 1.5 mA at 5 V DC | |
Signal level | 1-signal: 16 ... 30 V DC 0-signal: 0 ... 5 V DC | |
Output | ||
Connection side | field side | |
Output I | ||
Connection | terminals 1+, 2- or 3- | |
Internal resistor | 270 &Omega | |
Current | max. 45 mA | |
Voltage | min. 11.2 V | |
Open loop voltage | min. 23.5 V | |
Output signal | These values are valid for the rated operating voltage 19 ... 30 V DC. | |
Energized/De-energized delay | &le 20 ms / &le 20 ms | |
Line fault detection | signal at short-circuit RB < 50 &Omega, lead breakage RB > 10 k&Omega test current < 650 µA | |
Output II | fault signal | |
Connection | terminals 10, 11, 12 , non-intrinsically safe | |
Contact loading | 253 V AC/2 A/cos &phi > 0.7 40 V DC/2 A resistive load | |
Mechanical life | 2 x 107 switching cycles | |
Energized/De-energized delay | &le 20 ms / &le 20 ms | |
Indicators/settings | ||
Display elements | LEDs | |
Control elements | DIP-switch | |
Configuration | via DIP switches | |
Labeling | space for labeling at the front | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Low voltage | ||
Directive 2014/35/EU | EN 61010-1:2010 | |
Conformity | ||
Electromagnetic compatibility | NE 21:2007 | |
Degree of protection | IEC 60529:2001 | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Connection | screw terminals | |
Mass | approx. 150 g | |
Dimensions | 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) , housing type B2 | |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | ZELM 99 ATEX 0015 | |
Marking | ![]() ![]() ![]() | |
Certificate | TÜV 02 ATEX 1820 X | |
Marking | ![]() | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010 , EN 60079-26:2007 , EN 50303:2000 | |
International approvals | ||
CSA approval | ||
Control drawing | 116-0362 | |
IECEx approval | IECEx ZLM 14.0001 | |
Approved for | [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I |
General specifications | ||
---|---|---|
Signal type | Digital Output | |
Functional safety related parameters | ||
Safety Integrity Level (SIL) | SIL 2 | |
Supply | ||
Connection | Power Rail or terminals 14+, 15- | |
Rated voltage | 19 ... 30 V DC | |
Power dissipation | max. 1.5 W | |
Power consumption | max. 2 W at 45 mA output current | |
Input | ||
Connection side | control side | |
Connection | terminals 7, 8 | |
Input current | approx. 3 mA | |
Signal level | 1-signal: 16 ... 30 V DC 0-signal: 0 ... 5 V DC | |
Output | ||
Connection side | field side | |
Output I | ||
Connection | terminals 1+, 2- or 3- | |
Internal resistor | 300 &Omega | |
Current | max. 45 mA | |
Voltage | min. 10 V | |
Open loop voltage | min. 23.5 V | |
Output signal | These values are valid for the rated operating voltage 19 ... 30 V DC. | |
Energized/De-energized delay | &le 20 ms / &le 20 ms | |
Line fault detection | signal at short-circuit RB < 50 &Omega, lead breakage RB > 10 k&Omega test current < 650 µA | |
Output II | fault signal | |
Connection | terminals 10, 11, 12 , non-intrinsically safe | |
Contact loading | 253 V AC/2 A/cos &phi > 0.7 40 V DC/2 A resistive load | |
Mechanical life | 2 x 107 switching cycles | |
Energized/De-energized delay | &le 20 ms / &le 20 ms | |
Indicators/settings | ||
Display elements | LEDs | |
Control elements | DIP-switch | |
Configuration | via DIP switches | |
Labeling | space for labeling at the front | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Low voltage | ||
Directive 2014/35/EU | EN 61010-1:2010 | |
Conformity | ||
Electromagnetic compatibility | NE 21:2007 | |
Degree of protection | IEC 60529:2001 | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Connection | screw terminals | |
Mass | approx. 150 g | |
Dimensions | 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) , housing type B2 | |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | ZELM 99 ATEX 0015 | |
Marking | ![]() ![]() ![]() | |
Certificate | TÜV 02 ATEX 1820 X | |
Marking | ![]() | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010 , EN 60079-26:2007 , EN 50303:2000 | |
International approvals | ||
CSA approval | ||
Control drawing | 116-0362 | |
IECEx approval | IECEx ZLM 14.0001 | |
Approved for | [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I |
General specifications | ||
---|---|---|
Signal type | Digital Output | |
Functional safety related parameters | ||
Safety Integrity Level (SIL) | SIL 2 | |
Supply | ||
Connection | Power Rail or terminals 14+, 15- | |
Rated voltage | 19 ... 30 V DC | |
Power dissipation | max. 1.4 W | |
Power consumption | max. 2.3 W at 70 mA output current | |
Input | ||
Connection side | control side | |
Connection | terminals 7, 8 | |
Input current | approx. 3 mA | |
Signal level | 1-signal: 16 ... 30 V DC 0-signal: 0 ... 5 V DC | |
Output | ||
Connection side | field side | |
Output I | ||
Connection | terminals 1+, 2- or 3- | |
Internal resistor | 92 &Omega | |
Current | max. 70 mA | |
Voltage | min. 12.5 V | |
Open loop voltage | min. 19.2 V | |
Output signal | These values are valid for the rated operating voltage 19 ... 30 V DC. | |
Energized/De-energized delay | &le 20 ms / &le 20 ms | |
Line fault detection | signal at short-circuit RB < 50 &Omega, lead breakage RB > 10 k&Omega test current < 650 µA | |
Output II | fault signal | |
Connection | terminals 10, 11, 12 , non-intrinsically safe | |
Contact loading | 253 V AC/2 A/cos &phi > 0.7 40 V DC/2 A resistive load | |
Mechanical life | 2 x 107 switching cycles | |
Energized/De-energized delay | &le 20 ms / &le 20 ms | |
Indicators/settings | ||
Display elements | LEDs | |
Control elements | DIP-switch | |
Configuration | via DIP switches | |
Labeling | space for labeling at the front | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Low voltage | ||
Directive 2014/35/EU | EN 61010-1:2010 | |
Conformity | ||
Electromagnetic compatibility | NE 21:2007 | |
Degree of protection | IEC 60529:2001 | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Connection | screw terminals | |
Mass | approx. 150 g | |
Dimensions | 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) , housing type B2 | |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | ZELM 99 ATEX 0015 | |
Marking | ![]() ![]() ![]() | |
Certificate | TÜV 02 ATEX 1820 X | |
Marking | ![]() | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010 , EN 60079-26:2007 , EN 50303:2000 | |
International approvals | ||
CSA approval | ||
Control drawing | 116-0362 | |
IECEx approval | IECEx ZLM 14.0001 | |
Approved for | [Ex ia Ga] IIB, [Ex ia Da] IIIC, [Ex ia Ma] I |
General specifications | ||
---|---|---|
Signal type | Digital Output | |
Functional safety related parameters | ||
Safety Integrity Level (SIL) | SIL 2 | |
Supply | ||
Connection | Power Rail or terminals 14+, 15- | |
Rated voltage | 20 ... 30 V DC | |
Power consumption | max. 3.3 W at 45 mA output current | |
Input | ||
Connection side | control side | |
Connection | terminals 7, 8, 9 | |
Input current | approx. 3 mA at 24 V DC | |
Signal level | 1-signal: 16 ... 30 V DC 0-signal: 0 ... 5 V DC | |
Output | ||
Connection side | field side | |
Connection | channel 1: terminals 1+, 2-, 3 channel 2: terminals 4+, 5-, 6- | |
Internal resistor | 272 &Omega | |
Current | &le 45 mA | |
Voltage | &ge 11.7 V | |
Open loop voltage | min. 24 V | |
Output signal | These values are valid for the rated operating voltages from 20 ... 30 V DC. | |
Energized/De-energized delay | &le 20 ms / &le 20 ms | |
Line fault detection | signal at short-circuit RB < 50 &Omega, lead breakage RB > 10 k&Omega , test current < 650 µA | |
Indicators/settings | ||
Display elements | LEDs | |
Control elements | DIP-switch | |
Configuration | via DIP switches | |
Labeling | space for labeling at the front | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Conformity | ||
Electromagnetic compatibility | NE 21:2006 | |
Degree of protection | IEC 60529:2001 | |
Ambient conditions | ||
Ambient temperature | -20 ... 50 °C (-4 ... 122 °F) | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Connection | screw terminals | |
Mass | approx. 150 g | |
Dimensions | 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) , housing type B2 | |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | ZELM 00 ATEX 0024 | |
Marking | ![]() ![]() ![]() | |
Certificate | TÜV 02 ATEX 1820 X | |
Marking | ![]() | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010 , EN 60079-26:2007 , EN 50303:2000 | |
International approvals | ||
CSA approval | ||
Control drawing | 116-0304 | |
IECEx approval | IECEx TUN 04.0001 | |
Approved for | [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I |
Описание оборудования | ||
---|---|---|
without lead monitoring |
Описание оборудования | ||
---|---|---|
Output 22.3 V |
General specifications | ||
---|---|---|
Signal type | Analog input | |
Supply | ||
Connection | Power Rail or terminals 23+, 24- | |
Rated voltage | 19 ... 30 V DC | |
Rated current | approx. 120 mA at 24 V DC | |
Power dissipation | 2.3 W | |
Power consumption | 2.9 W | |
HART signal channels (intrinsically safe) | ||
Conformity | HART field device input (revision 5 to 7) | |
Interface | ||
Programming interface | programming socket | |
Input | ||
Connection side | field side | |
Connection | terminals 1, 2, 3, 4, 5, 6 | |
Open circuit voltage/short-circuit current | typ. 24 V / 28 mA | |
Input resistance | 250 &Omega , 5 % (terminals 2, 3 and with jumper on 5, 6) | |
Available voltage | &ge 15.5 V at 20 mA, short-circuit protected | |
Output | ||
Connection side | control side | |
Connection | output I: terminals 7, 8, 9 , output II: terminals 13, 14, 15 , output III: terminals 19, 20, 21 | |
Output signal | analog | |
Current range | 4 ... 20 mA , (source or sink mode) | |
Load | max. 650 &Omega , source mode | |
Voltage range | 5 ... 30 V , sink mode from external supply | |
Fault signal | downscale I &le 2 mA, upscale I &ge 21.5 mA (acc. NAMUR NE43) or hold measurement value | |
Other outputs | HART communicator on terminals 22, 24 | |
Collective error message | Power Rail and LED red | |
Indicators/settings | ||
Display elements | LEDs , display | |
Control elements | Control panel | |
Configuration | via operating buttons via PACTware | |
Labeling | space for labeling at the front | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Low voltage | ||
Directive 2014/35/EU | EN 61010-1:2010 | |
Conformity | ||
Electromagnetic compatibility | NE 21:2006 | |
Degree of protection | IEC 60529:2001 | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Connection | screw terminals | |
Mass | 300 g | |
Dimensions | 40 x 119 x 115 mm (1.6 x 4.7 x 4.5 inch) , housing type C3 | |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | BASEEFA 07 ATEX 0174 | |
Marking | ![]() | |
Certificate | PF 07 CERT 1142 X | |
Marking | ![]() | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010 | |
International approvals | ||
FM approval | ||
Control drawing | 116-0129 | |
IECEx approval | ||
IECEx certificate | IECEx BAS 07.0047 | |
IECEx marking | [Ex ia] IIC , [Ex iaD] |
General specifications | ||
---|---|---|
Signal type | Analog input | |
Supply | ||
Connection | Power Rail or terminals 23+, 24- | |
Rated voltage | 19 ... 30 V DC | |
Rated current | approx. 130 mA at 24 V DC | |
Power dissipation | 2.5 W | |
Power consumption | 3.1 W | |
HART signal channels (intrinsically safe) | ||
Conformity | HART field device input (revision 5 to 7) | |
Interface | ||
Programming interface | programming socket | |
Input | ||
Connection side | field side | |
Connection | terminals 1, 2, 3, 4, 5, 6 | |
Open circuit voltage/short-circuit current | typ. 24 V / 28 mA | |
Input resistance | 250 &Omega , 5 % (terminals 2, 3 and with jumper on 5, 6) | |
Available voltage | &ge 15.5 V at 20 mA, short-circuit protected | |
Output | ||
Connection side | control side | |
Connection | output I: terminals 10, 11, 12, output II: terminals 16, 17, 18 output III: terminals 7, 8, 9, output IV: terminals 13, 14, 15, output V: terminals 19, 20, 21 | |
Output I, II | ||
Output signal | relay and LED yellow | |
Mechanical life | 107 switching cycles | |
Energized/De-energized delay | approx. 20 ms / approx. 20 ms | |
Output III, IV, V | ||
Output signal | analog | |
Current range | 4 ... 20 mA , (source or sink mode) | |
Load | max. 650 &Omega , source mode | |
Voltage range | 5 ... 30 V , sink mode from external supply | |
Fault signal | downscale I &le 2 mA, upscale I &ge 21.5 mA (acc. NAMUR NE43) or hold measurement value | |
Other outputs | HART communicator on terminals 22, 24 | |
Collective error message | Power Rail and LED red | |
Transfer characteristics | ||
Relay | programmable either for fault or trip value (with direction, hysteresis and delay) | |
Indicators/settings | ||
Display elements | LEDs , display | |
Control elements | Control panel | |
Configuration | via operating buttons via PACTware | |
Labeling | space for labeling at the front | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Low voltage | ||
Directive 2014/35/EU | EN 61010-1:2010 | |
Conformity | ||
Electromagnetic compatibility | NE 21:2006 | |
Degree of protection | IEC 60529:2001 | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Connection | screw terminals | |
Mass | 300 g | |
Dimensions | 40 x 119 x 115 mm (1.6 x 4.7 x 4.5 inch) , housing type C3 | |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | BASEEFA 07 ATEX 0174 | |
Marking | ![]() | |
Certificate | PF 07 CERT 1141 X | |
Marking | ![]() | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010 | |
International approvals | ||
FM approval | ||
Control drawing | 116-0129 | |
IECEx approval | ||
IECEx certificate | IECEx BAS 07.0047 | |
IECEx marking | [Ex ia] IIC , [Ex iaD] |
General specifications | ||
---|---|---|
Signal type | Analog input | |
Supply | ||
Connection | Power Rail or terminals 23+, 24- | |
Rated voltage | 19 ... 30 V | |
Rated current | approx. 140 mA at 24 V DC | |
Power dissipation | 2.7 W | |
Power consumption | 3.3 W | |
HART signal channels (intrinsically safe) | ||
Conformity | HART field device input (revision 5 to 7) | |
Interface | ||
Programming interface | programming socket | |
Input | ||
Connection side | field side | |
Connection | terminals 1, 2, 3, 4, 5, 6 | |
Open circuit voltage/short-circuit current | typ. 24 V / 28 mA | |
Input resistance | 250 &Omega , 5 % (terminals 2, 3 and with jumper on 5, 6) | |
Available voltage | &ge 15.5 V at 20 mA, short-circuit protected | |
Output | ||
Connection side | control side | |
Connection | output I: terminals 10, 11, output II: terminals 11, 12, output III: terminals 16, 17, output IV: terminals 17, 18 output V: terminals 7, 8, 9, output VI: terminals 13, 14, 15, output VII: terminals 19, 20, 21 | |
Output I, II, III, IV | ||
Output signal | relay and LED yellow | |
Mechanical life | 107 switching cycles | |
Energized/De-energized delay | approx. 20 ms / approx. 20 ms | |
Output V, VI, VII | ||
Output signal | analog | |
Current range | 4 ... 20 mA , (source or sink mode) | |
Load | max. 650 &Omega , source mode | |
Voltage range | 5 ... 30 V , sink mode from external supply | |
Fault signal | downscale I &le 2 mA, upscale I &ge 21.5 mA (acc. NAMUR NE43) or hold measurement value | |
Other outputs | HART communicator on terminals 22, 24 | |
Collective error message | Power Rail and LED red | |
Transfer characteristics | ||
Relay | programmable either for fault or trip value (with direction, hysteresis and delay) | |
Indicators/settings | ||
Display elements | LEDs , display | |
Control elements | Control panel | |
Configuration | via operating buttons via PACTware | |
Labeling | space for labeling at the front | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Low voltage | ||
Directive 2014/35/EU | EN 61010-1:2010 | |
Conformity | ||
Electromagnetic compatibility | NE 21:2006 | |
Degree of protection | IEC 60529:2001 | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Connection | screw terminals | |
Mass | 300 g | |
Dimensions | 40 x 119 x 115 mm (1.6 x 4.7 x 4.5 inch) , housing type C3 | |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | BASEEFA 07 ATEX 0174 | |
Marking | ![]() | |
Certificate | PF 07 CERT 1141 X | |
Marking | ![]() | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010 | |
International approvals | ||
FM approval | ||
Control drawing | 116-0129 | |
IECEx approval | ||
IECEx certificate | IECEx BAS 07.0047 | |
IECEx marking | [Ex ia] IIC , [Ex iaD] |
Описание оборудования | ||
---|---|---|
Input 4 mA ... 20 mA Output 4 mA ... 20 mA |
Описание оборудования | ||
---|---|---|
Input 0/4 mA ... 20 mA 2 x Output 0/4 mA ... 20 mA |
Описание оборудования | ||
---|---|---|
Input 0/4 mA ... 20 mA 2 x Output 0/4 mA ... 20 mA |
Описание оборудования | ||
---|---|---|
Input 0/4 mA ... 20 mA 2 x Output 0/4 mA ... 20 mA |
Описание оборудования | ||
---|---|---|
Input 4 mA ... 20 mA Output 4 mA ... 20 mA |
Товаров: 0